background image

 

- 98 -

 

 

ii: 

Wide space width 

01 to 99 (in dots) 

 

 

 

*  In the case of industrial 2 of 5, the value is fixed to 00. 

 

 

jj: 

Character-to-character space width 

01 to 99 (in dots) 

 

 

 

* In the case of MSI and ITF, character-to-character space width is set to 00. 

 

 

k: 

Rotational angle of bar code 

0: 0° 
1: 90° 
2: 180° 
3: 270° 

 

 

llll: 

Height of the bar code 

0000 to 1000 (in 0.1 mm units) 

  mnnnnnnnnnn: 

Increment/decrement 

 

(Omissible.  If omitted, incrementing/decrementing is not 
performed.) 

 

 

 

m: 

Indicates whether to increment or decrement 
 +: Increment 
 -: Decrement 

  

nnnnnnnnnn: 

Skip 

value 

  0000000000 to 9999999999 

 

 

p: 

Selection of print or non-print of numerals under bars 
(Omissible.    If omitted, the numerals under the bars are not printed.) 

    

0: 

Non-print 

1: Print 

 

 

qq: 

No. of zeros to be suppressed 
(Omissible.    If omitted, the zero suppression process is not performed.) 
  00 to 20 

 

 

r: 

Designates the attachment of start/stop code 
(Omissible.    If omitted, the start/stop code is automatically attached.) 

 

 

 

T:  Attachment of start code only 
P:  Attachment of stop code only 
N:  Start/stop code unattached 

 

 

sss------sss: 

Data string to be printed (Omissible) 

 

 

 

Max. 126 digits.    However, the number of digits varies depending on 
the type of bar code. 

  tt

1

, tt

2

, tt

3

, ------, tt

20

Link field No. (Omissible) 

 

 

 

  01 to 99 (1 to 99 can also be used.) 

Up to 20 fields can be designated using commas. 

Содержание B-SX4T Series

Страница 1: ...003 3rd Edition June 6 2003 4th Edition August 22 2003 5th Edition February 27 2004 6th Edition January 14 2005 7th Edition February 8 2005 8th Edition May 9 2005 9th Edition April 4 2006 10th Edition May 23 2007 11th Edition April 18 2008 12th Edition November 13 2008 13th Edition January 23 2009 14th Edition March 6 2009 15th Edition October 30 2009 ...

Страница 2: ...BEL SIZE SET COMMAND 37 6 3 2 POSITION FINE ADJUST COMMAND 43 6 3 3 PRINT DENSITY FINE ADJUST COMMAND 51 6 3 4 RIBBON MOTOR DRIVE VOLTAGE FINE ADJUST COMMAND 52 6 3 5 IMAGE BUFFER CLEAR COMMAND 53 6 3 6 CLEAR AREA COMMAND 54 6 3 7 LINE FORMAT COMMAND 56 6 3 8 BIT MAP FONT FORMAT COMMAND 60 6 3 9 OUTLINE FONT FORMAT COMMAND 77 6 3 10 BAR CODE FORMAT COMMAND 94 6 3 11 BIT MAP FONT DATA COMMAND 143 6...

Страница 3: ...NFORMATION ACQUIRE COMMAND 232 6 3 38 PRINTER OPTION STATUS ACQUIRE COMMAND 233 6 3 39 IP ADDRESS SET COMMAND 234 6 3 40 SOCKET COMMUNICATION PORT SET COMMAND 235 6 3 41 DHCP FUNCTION SET COMMAND 236 6 3 42 PASS THROUGH COMMAND 237 6 3 43 INTERNAL SERIAL INTERFACE PARAMETER SET COMMAND 238 6 4 COMMANDS FOR SYSTEM ADMINISTRATOR 239 6 4 1 PARAMETER SET COMMAND 239 6 4 2 FINE ADJUSTMENT VALUE SET COM...

Страница 4: ...ETICA LETTER GOTHIC PRESTIGE ELITE COURIER GOTHIC725 BLACK 281 12 2 PRESENTATION 288 12 3 OCR A 292 12 4 OCR B 299 12 5 TEC OUTLINE FONT 1 305 12 6 PRICE FONT 1 2 3 312 12 7 TEC OUTLINE FONT 2 3 GOTHIC725 BLACK 313 12 8 GB2312 80 CHINESE KANJI 16 16 24 24 32 32 48 48 320 12 9 TrueType FONT 325 12 10 GB18030 2 BYTE CODE 332 12 11 GB18030 4 BYTE CODE 348 13 BAR CODE TABLE 356 14 DRAWING OF BAR CODE ...

Страница 5: ...ferred to as B SX5T industrial high performance class general purpose bar code printers 2 GENERAL DESCRIPTION The external equipment interface connects a printer to the host computer through a serial interface RS 232C USB parallel interface Centronics or a network for making various settings and printing labels This specification describes how to use the external equipment interface for the TPCL T...

Страница 6: ...B X X X X V2 1 X X X X V3 0 X X X X V3 1 X X X X V3 2 X X X X V3 3 X X X X V3 3A X X X X V4 1 X X X X V4 2 X X X X V4 2A X X X X V4 4 X X Note2 X Note2 X V4 4A X X X X V4 4C X4 4C C4 4C X X X X X X X X X X X X X X X X X X X X X V4 5 X4 5 C4 5 X X X X X X X X X X X X X X X X X X X X X V4 6 X4 6 C4 6 X X X X X X X X X X X X X X X X X X X X X V4 6A X4 6A C4 6A X X X X X X X X X X X X X X X X X X X X ...

Страница 7: ... MAIN3 R or earlier PC board The MAIN4 R or greater is required Be careful of the combination Main PC board MAIN4 R or greater MAIN3 R or earlier Boot program V3 0 or greater Downloaded normally When the boot program is sent to the printer by the downloader the printer shows MODEL TYPE ERROR on the LCD and results in an error When the COM is used as the interface the downloader shows Check Sum Err...

Страница 8: ...e printer is restarted it starts up in the previous status Downloaded normally Main program earlier than V5 0 When the main program is sent to the printer by the downloader the printer writes the program shows FIRM VER INVALID on the LCD and results in an error When the COM is used as the interface the downloader shows Erase Error Then the printer is forcibly shut down After the printer restarted ...

Страница 9: ... band for EU None Option None RFID module UHF band for CN None None Option RFID module UHF band for AU Option None None RFID module HF band for QM None Option None Model B SX4T GS20 QM R B SX4T GS20 CN R Firmware version V5 0 or greater Flash ROM 8 MB 1 8 MB Memory Whole 16 MB 1 16 MB SDRAM Image buffer of whole SDRAM 1 2 MB Label length 1500 mm Bitmap Kanji ROM Mincho None Bitmap Kanji ROM Gothic...

Страница 10: ...None Option RFID module UHF band for AU Option None None RFID module HF band for QM None Option None Model B SX5T TS22 QM R B SX5T TS22 CN R Firmware version V5 0 or greater Flash ROM 8 MB 1 8 MB Memory Whole 32 MB 1 32 MB SDRAM Image buffer of whole SDRAM 3 3 MB Label length 1500 mm Bitmap Kanji ROM Mincho None Bitmap Kanji ROM Gothic None Standard from V5 1 Chinese ROM None Standard RS 232C Stan...

Страница 11: ...cturer s Code Operation 1 MB Maxell EF 1M TB AA D0H 1CH Read only Mitsubishi MF81M1 GBDAT01 4 MB Maxell EF 4M TB CC 88H B0H Read Write Maxell EF 4M TB DC ADH 04H Centennial Technologies INC FL04M 15 11119 03 01H INTEL IMC004FLSA A2H 89H Read only Simple TECNOLOGY STI FL 4A Mitsubishi MF84M1 G7DAT01 PC Card KING MAX FJN 004M6C Centennial Technologies INC FL04M 20 11138 67 PC Card FJP 004M6R A0H Mit...

Страница 12: ...Bit 1 bit 2 bits 7 Data Length 7 bits 8 bits 8 Parity None Even Odd 9 Error Detection Parity error Vertical parity error check Framing error This error occurs if no stop bit is found in the frame specified starting with the start bit 10 Protocol No procedure method 11 Data Input Code ASCII code European character set 8 bit code Graphics 8 bit code 12 Receive Buffer For B SX4T 1 MB For B SX5T 6 MB ...

Страница 13: ...ust stop transmission before the printer receive buffer becomes full z The printer sends an XOFF code 13H when the power is off Transmission or non transmission of the XOFF code is selectable by means of the parameter setting z The DTR signal is always High READY z The RTS signal is always High d READY BUSY DTR Protocol z When initialized after the power is turned on this printer becomes ready to ...

Страница 14: ... RTS Protocol z When initialized after the power is turned on this printer turns the RTS signal to High READY z The printer turns the RTS signal to Low BUSY when the blank positions in the receive buffer become 10 Kbytes or less z The printer turns the RTS signal to High READY when the blank positions in the receive buffer become 512 Kbytes or more z When there are no blank positions in the receiv...

Страница 15: ...5 RTS z Output signal to the host For the READY BUSY RTS protocol z It indicates the ready state for the received data z It is at Low when the receive buffer is nearly full and at High when nearly empty For protocol other than the READY BUSY RTS protocol z After the power is turned on it is always at High level Printer 6 DTR z Output signal to the host For the READY BUSY DTR protocol or XON XOFF D...

Страница 16: ...12 RD CTS DSR SN75189 or equivalent SN75188 or equivalent TD RTS DTR 16 Interface Circuit z Input Circuit z Output Circuit z Signal Levels Input Voltage H 3 15 V L 3 15 V Output Voltage H 6 13 V L 6 13 V ...

Страница 17: ... HostClk HostClk nAck PrtClk PeriphClk Busy PtrBusy PeriphAck PError AckDataReq nAckReverse Select Xflag XFlag nAutoFd HostBusy HostAck nInit nInit nReverseRequest nFault nDataAvail nPeriphRequest nSelectIn IEEE1284Active IEEE1284Active 5 Data Input Code ASCII code European character set 8 bit code Graphics 8 bit code 6 Receive Buffer For B SX4T 1 MB For B SX5T 6 MB The use of the receive buffer i...

Страница 18: ... 1 2 5 V 0 0 0 4 V Outpu t Busy PtrBusy PeriphAck nFault nDataAvail nPeriphRequest nAck PtrClk PeriphClk Select Xflag XFlag PError AckDataReq nAckReverse Logic level Input 1 2 4 5 V 0 0 0 4 V 8 Connector Printer Amp Japan 552742 1 or equivalent DDK 57RE 40360 73B or equivalent Cable Amp Japan 552470 1 or equivalent DDK 57E 30360 or equivalent 1K SN74LS245 or equivalent 5V 100P 5V 1K SN74LS14 or eq...

Страница 19: ... PIN3 TWISTED PAIR GND PIN3 TWISTED PAIR GND PIN3 22 TWISTED PAIR GND PIN4 TWISTED PAIR GND PIN4 TWISTED PAIR GND PIN4 23 TWISTED PAIR GND PIN5 TWISTED PAIR GND PIN5 TWISTED PAIR GND PIN5 24 TWISTED PAIR GND PIN6 TWISTED PAIR GND PIN6 TWISTED PAIR GND PIN6 25 TWISTED PAIR GND PIN7 TWISTED PAIR GND PIN7 TWISTED PAIR GND PIN7 26 TWISTED PAIR GND PIN8 TWISTED PAIR GND PIN8 TWISTED PAIR GND PIN8 27 TW...

Страница 20: ...conds when data is set from the host to extend the data read interval z When there are no blank positions in the receive buffer the printer stops reading data Then it keeps the signal at High level in a Busy state until there are blank positions in the receive buffer when data is set from the host z The signal is kept at High level in a Busy state until the current state one of the following state...

Страница 21: ...evel while the printer is in a Pause state z The signal is kept at Low level in a Pause state until the current state one of the following states is reset Pause state caused by the PAUSE key Paper end state Ribbon end state Head open state Printer error state Initialization in progress upon power on or receipt of the nInit signal i nFault Printer Host z Output signal indicating that the printer is...

Страница 22: ...ansfer Data bit 5 is used for the second transfer g HostBusy Printer Host z Reverse data transfer phase It indicates that the host can receive data from the printer by setting the signal to low Then the host sets the signal to high and sends the Ack indicating that the nibble data is received When the signal is set to low after the reverse channel data transfer is performed the interface phase cha...

Страница 23: ...ate the bidirectional data signal h XFlag Printer Host z i nPeriphRequest Printer Host z In the ECP mode peripheral equipment can make this signal LOW for requesting communications with the host The request is just only a Hint for the host The host ultimately controls the transfer direction This signal provides the peer to peer communication mechanism This signal is usually used for generating an ...

Страница 24: ...been installed b Timing 2 Data 1 8 Host Printer nStrobe Host Printer Busy Host Printer nAck Host Printer Approx 5 µsec Min 1 µsec Min 1 µsec Min 0 5 µsec Data 1 8 Host Printer nStrobe Host Printer Busy Host Printer nAck Host Printer Min 1 µsec Min 1 µsec Min 0 5 µsec Approx 1 µsec Data 1 8 Host Printer nStrobe Host Printer Busy Host Printer nAck Host Printer Approx 10 µsec Min 1 µsec Min 1 µsec Mi...

Страница 25: ... SPP When the Compatibility mode is selected for the printer setting the printer does not respond to the ECP negotiation from the host When the ECP mode is selected for the printer setting the Busy signal does not become HIGH even if an error occurs SPP mode operations include support for the Nibble mode When SPP mode is selected for the printer setting the printer returns 13 bytes of status descr...

Страница 26: ... status block STX 02H Status 3XH Printer status 3XH For details see section 9 1 1 STATUS FORMAT Status type 33H Indicates that the status includes the receive buffer free space information Remaining 3XH Remaining issue count count 3XH For details see section 9 1 1 STATUS FORMAT 3XH 3XH Length 3XH Total number of bytes of this status block 3XH Free space 3XH Free space of the receive buffer of rece...

Страница 27: ...3 Data transfer in ECP mode of section 3 2 PARALLEL INTERFACE 3 4 NETWORK INTERFACE 1 Configuration c PCMCIA board LAN card d 100BASE LAN board e PCMCIA board Wireless LAN card 2 Protocol TCP IP 3 Network Specifications c LPR server function d WEB printer function e Socket communication function f FTP server function g Mail transmission reception function For more details on the network refer to t...

Страница 28: ...d feed standby action Head up operation in cut issue mode or the use of the rewinder in batch issue mode Installed solenoid type setting Use of ribbon saving system Control code Peel off wait status selection FEED key function Kanji code selection Euro code setting Automatic head broken dots check Centronics ACK BUSY timing setting Web printer function setting Reset process when the nInit signal i...

Страница 29: ...tout Non printing Line printout for the assembly process Automatic printout for the assembly process Transmissive sensor Automatic printout for the assembly process Reflective sensor 5 Sensor display adjustment Thermal head temperature sensor display Open air temperature sensor display Heat sink sensor display Reflective sensor display adjustment Transmissive sensor display adjustment Reflective s...

Страница 30: ...eter Initial Value Label distance covered 0 km Printed distance 0 km Cut count 0 Head up down count 0 Ribbon motor drive time 0 hour Head up solenoid drive time 0 hour RS 232C hardware error count 0 System error count 0 Momentary power interruption count 0 Initial values after parameter clear Parameter Initial Value Feed fine adjustment PC 0 mm Cut position or strip position fine adjustment PC 0 m...

Страница 31: ...pe READY BUSY DTR protocol CN type XON XOFF READY BUSY DTR protocol XON output when the power is on XOFF output when the power is off Language for LCD messages QP type English QQ type English CN type English Forward feed standby after an issue OFF Forward feed standby action MODE 1 Head up operation in cut issue mode or use of the rewinder OFF Head up operation is not operated the rewinder is not ...

Страница 32: ...ule type selection None RFID tag type selection None RFID module s destination code setting Depends on the module setting RFID error tag detection OFF Password to protect error tag detection OFF 0000 Access password setting 00000000 Automatic unlock function setting OFF Max number of RFID issue retries 3 Max number of RFID read retries 5 RFID read retry timeout 4 0 sec Max number of RFID write ret...

Страница 33: ...ing and automatic unlock function setting are not cleared by RAM clear The values in the table are the factory default 4 2 ONLINE MODE FUNCTIONS The online mode provides the following functions for issuing labels and setting the threshold For details refer to Key Operation Specification TAA 1379 1 Issuing labels by external equipment interface commands 2 Paper feed by the FEED key 3 Pause Halts is...

Страница 34: ...el issue operation is performed after storing writable characters or logos the image buffer will be cleared automatically 4 If another storing operation does not take place after storing writable characters or logos the printer automatically enters the online mode label issue operation after about 10 seconds In this case when the flash memory card is used the image buffer will be cleared automatic...

Страница 35: ...ll be cleared automatically Power ON New Format Command Bit Map Font Data Command No Yes Add change ESC J1 Formats the flash memory card or ESC JA Formats the ATA card Completion of all storing z Storing writable characters or logos z Label issue operation No Yes ESC XO ESC XV Declares the start of saving PC interface commands Save Start Command Label Size Set Command Position Fine Adjust Command ...

Страница 36: ... Fine Adjust Command Print Density Fine Adjust Command Image Buffer Clear Command Line Format Command Bit Map Font Format Command Outline Font Format Command Bar Code Format Command ESC D Sets the label size ESC AX Adjusts the feed length cut position and back feed length ESC AY Adjusts the print density ESC C Clears the image buffer ESC LC Sets the line format and draws it ESC PC Sets the bit map...

Страница 37: ... Print data in XML format can be sent to the printer For details refer to the XML Data Print Specification TAA 1320 Power ON Bit Map Font Data Command Change data issue Yes Place paper Saved Data Call Command ESC XQ Calls the label format stored in the flash memory card or ESC XT Calls the label format stored in the ATA card ESC RC Draws bit map font data Feed Command ESC T Feeds one sheet of pape...

Страница 38: ...positions before being transmitted Term Explains the term s used in the format 0 to 999 described in the entry range indicates that up to 3 digit variable length entry is allowed Entry of 001 or 009 is also possible 000 to 999 indicates that the entry must be fixed as 3 digits Explanation Explains the command in detail Note Supplementary explanation of the command Refer to Related commands Example...

Страница 39: ... Commands related to issue and feed Issue Command ESC XS 164 Feed Command ESC T 180 Eject Command ESC IB 187 Forward Reverse Feed Command ESC U1 ESC U2 189 7 Commands related to writable characters Storage Area Allocate Command ESC XF 191 Flash Memory Format Command ESC J1 195 ATA Card Format Command ESC JA 196 2 byte Writable Character Code Range Command ESC XE 197 Bit Map Writable Character Comm...

Страница 40: ...232 Printer Option Status Acquire Command ESC WN 233 14 Commands related to TCP IP setting IP Address Set Command ESC IP 234 Socket Communication Port Set Command ESC IS 235 DHCP Function Set Command ESC IH 236 15 Commands related to internal serial interface Pass through Command ESC 002 237 Internal Serial Interface Parameter Set Command ESC IZ 238 16 Commands related to parameter setting Paramet...

Страница 41: ... in 0 1 mm units 4 digits 0060 6 0 mm to 9999 999 9 mm 5 digits 00060 6 0 mm to 14980 1498 0 mm dddd Backing paper width Omissible If omitted the initial value is the effective print width Fixed as 4 digits in 0 1 mm units B SX4T 0300 30 0 mm to 1120 112 0 mm B SX5T 0300 30 0 mm to 1400 140 0 mm Explanation 0 X Y Label Paper feed direction Label pitch Backing paper Origin of coordinates 0 0 Effect...

Страница 42: ... Origin d Cut position Origin of coordinates 0 0 Tags Tag Paper feed direction 0 X Y Tag pitch Black mark Back side of print Origin of coordinates 0 0 Effective print length Effective print width Print direction Printing bottom first Tag Paper feed direction Tag pitch Effective print length Effective print width 0 X Y Printing direction Printing top first Black mark Back side of ...

Страница 43: ...in 8 0 23 4 25 0 3 6 ips 2 93 0 6 ips 32 0 8 0 23 4 25 0 7 5 ips 5 89 0 5 ips 25 0 10 ips NOTE 1 10 ips NOTE 1 8 ips 6 100 0 8 ips 25 0 Max 1498 0 1494 0 1498 0 1494 0 Min 30 0 50 0 30 0 30 0 50 0 30 0 C Backing paper width Tag width Max 112 0 140 0 112 0 D Label width Min 27 0 27 0 Max 109 0 137 0 109 0 E Label to label gap Min 2 0 6 0 2 0 6 0 Max 20 0 20 0 F Black mark length Min 2 0 2 0 Max 10 ...

Страница 44: ...ormed at 3 ips by using the rotary cutter label length B should be as follows Label length B 91 0 mm 5 When a cut issue is performed at 5 ips by using the rotary cutter label length Bshould be as follows Label length B 99 0 mm 6 When a cut issue is performed at 8 ips by using the rotary cutter label length Bshould be as follows Label length B 110 0 mm 7 When a cut issue is performed by using the s...

Страница 45: ...op and cut position are adjustable by the Fine Adjust Commands and according to the fine adjustment settings in the system mode 7 The tag rotation designation of the Issue Command ESC XS causes the origin of drawing coordinates to be origin c in the case of printing bottom first and to be origin d in the case of printing top first as shown in the figure 8 The parameters must be as shown in the fig...

Страница 46: ...8 0760 0468 0820 LF NUL ESC D0762 0996 0722 LF NUL ESC T20C30 LF NUL ESC T10C30 LF NUL 46 8 mm 50 8 mm 76 0 mm Effective print area Label Backing paper 72 2 mm 76 2 mm 99 6 mm Effective print area Tag Black mark Back side of print 82 0 mm ...

Страница 47: ... the home position after cutting or adjusts the value for feeding the label back to the home position after stripping Format ESC AX abbb cddd eff LF NUL Term a Indicates the direction forward or backward in which a fine adjustment is to be made Backward Forward bbb Feed value to be finely adjusted 000 to 500 in 0 1 mm units c Indicates the direction forward or backward in which a cut position or s...

Страница 48: ... Position Fine Adjustment To finely adjust the cut position for shifting backward or forward 0 0 mm 3 0 mm 3 0 mm First print position Paper feed direction One label One label One label First print position First print position 0 0 mm 3 0 mm Cut position Cut position Cut position 3 0 mm Paper feed direction ...

Страница 49: ...ion fine adjust function When the label to label gap is 5 mm or more the effective print length should be set to the maximum label pitch 2 mm Then the print stop position should be adjusted using the strip position fine adjust function Back Feed Fine Adjustment To finely adjust the back feed for shifting backward or forward 0 0 mm 3 0 mm 3 0 mm 0 0 mm 3 0 mm First print position home position afte...

Страница 50: ...so that the label is correctly fed back to the position placed before the forward feed is performed 5 The cut position or the strip position fine adjustment and the back feed fine adjustment are effective only when the printer is in cut issue or strip issue mode 6 Procedure for label having label pitch of less than 38 mm when the swing cutter is used The minimum label pitch of the label which can ...

Страница 51: ...els are left between the head and the cutter Therefore these labels should be removed by an issue or a label feed a Cut position fine adjustment value calculation The cut position fine adjustment value can be calculated using the following method If a back feed to the proper home position cannot be performed using this value the cut position should be adjusted with any value Ex Label pitch 30 0 mm...

Страница 52: ... of label C B C 2 Completes printing the first label A 3 Feeds the label to the cut position then cuts the gap at the front of label A 8 To eject label B feeds the third label C 10 Feeds back to the home position B C C A B A 4 Feeds back to the home position B C B 6 Feeds the label to the cut position then cuts the gap at the front of label B A A B 7 Feeds back to the home position C A B C A B C C...

Страница 53: ...nstalled the head up down operations are not performed See NOTES below NOTES 1 If the head is being lifted when the edge of the label which is being ejected passes the paper feed roller the sensor may not be able to detect an error even if it occurs a feed cannot be performed more 2 If the head up solenoid temperature is high when a cut issue is about to be performed with the head lifted the head ...

Страница 54: ...mm 3 5 mm 3 0 mm Cut Paper feed direction Preprinted z Finely adjust the print position by 2 0 mm z Finely adjust the cut position by 3 5 mm z Finely adjust the back feed value by 1 0 mm 3 0 2 0 1 0 1 0 mm 3 0 mm A B C 1 0 mm Paper feed direction A B C z Finely adjust the strip position by 2 0 mm z Finely adjust the print position by 1 0 mm ...

Страница 55: ...ent values in thermal transfer print mode and direct thermal print mode can be set independently 4 The Print Density Fine Adjust Command is protected in memory even if the power is turned off 5 The fine adjustment value for both the fine adjust command and the system mode fine adjustment is 00 at shipment from the factory 6 The maximum value for each print speed is as follows When the value exceed...

Страница 56: ...rive voltage fine adjustment value is protected in memory even if the power is turned off 4 If the ribbon motor drive voltage fine adjustment value has been set in the system mode key operation on the printer the fine adjustment value will be the sum of the system mode and the ribbon rewind motor adjustments or the system mode and the ribbon back tension motor adjustments The max fine adjustment v...

Страница 57: ...on described later is valid until the Image Buffer Clear Command is transmitted 3 The link field designation described later is effective until the Image Buffer Clear Command is sent 4 The RFID format and data are cleared 5 RFID tag position adjustment value set in the RFID Tag Position Adjustment Command 003 is cleared Examples ESC D0508 0760 0468 LF NUL ESC T20C51 LF NUL ESC C LF NUL ESC RC000 A...

Страница 58: ...verses the white black dot pattern in the designated area Explanation Print direction Printing bottom first Print direction Printing top first Notes 1 The result is the same even if the start and end point coordinates are reversed 2 The result is the same even if the start and end point coordinates are set to an upper right and a lower left points respectively 3 The start and end point coordinates...

Страница 59: ... 23 0 6 ips 91 0 6 ips 30 0 6 0 21 4 23 0 5 ips 87 0 5 ips 23 0 10 ips NOTE 1 10 ips NOTE 1 8 ips 98 0 8 ips 23 0 Max 1496 0 1492 0 1496 0 1492 0 3 ips 28 0 3 ips 28 0 Tag Min 8 0 23 4 6 ips 28 0 8 0 23 4 5 ips 28 0 10 ips NOTE 1 8 ips 36 0 Max 1498 0 1498 0 1498 0 1498 0 NOTE 1 The use of the rotary cutter at 10 ips is not supported for the B SX4T Examples ESC XR 0345 0100 0762 0585 A LF NUL ESC ...

Страница 60: ...horizontal vertical slant 1 Rectangle f No of line width dots 1 to 9 in 0 1 mm units ggg Radius of rounded corners of rectangles Omissible If omitted the chamfering process for rectangle corners is not performed Fixed as 3 digits in 0 1 mm units Explanation Print direction Printing bottom first Print direction Printing top first Backing paper Label Paper feed direction 0 X Y Backing paper Effectiv...

Страница 61: ...of Y2 Y1 0 2 Vertical line In the case of X2 X1 0 3 Slant line A X2 X1 Y2 Y1 4 Slant line B X2 X1 Y2 Y1 X1 Y1 X2 Y2 Line width X1 Y1 X2 Y2 Line width X1 Y1 X2 Y2 X1 Y1 X2 Y2 Line width Line width X1 Y1 X2 Y2 X1 Y1 X2 Y2 Line width Line width ...

Страница 62: ...g to the start and end point coordinates 2 The result is the same even if the start and end point coordinates are reversed 3 The start and end point coordinates must be set so that the result of line drawing will be within the effective print area set by the Label Size Set Command ESC D X1 Y1 X2 Y2 X1 Y1 X2 Y2 Line width Line width Line width Line width Radius X2 Y2 Line width Line width X1 Y1 ...

Страница 63: ...ration performed Effective print width Min 10 0 10 0 Max 104 0 128 0 Effective print length 3 ips 79 0 3 ips 30 0 3 ips 79 0 3 ips 23 0 Label Min 6 0 21 4 23 0 6 ips 91 0 6 ips 30 0 6 0 21 4 23 0 5 ips 87 0 5 ips 23 0 10 ips NOTE 1 10 ips NOTE 1 8 ips 98 0 8 ips 23 0 Max 1496 0 1492 0 1496 0 1492 0 3 ips 28 0 3 ips 28 0 Tag Min 8 0 23 4 6 ips 28 0 8 0 23 4 5 ips 28 0 10 ips NOTE 1 8 ips 36 0 Max 1...

Страница 64: ... 1 06 09 0 6 to 0 9 magnifications d d Designation in 0 5 magnification units 0 or 5 5 to 9 up to 1 magnification Designation in magnifications 0 to 9 e Character vertical magnification 1 to 9 in magnifications Two digit designation enables magnifications in 0 5 units 05 95 0 5 to 9 5 magnifications The magnification can be designated in 0 1 units between 0 5 and 1 06 09 0 6 to 0 9 magnifications ...

Страница 65: ...1 a Writable character 1 1 1 dot to 720 720 dots to 40 a Writable character 40 1 1 dot to 720 720 dots 51 a 2 byte code set writable character 1 1 1 dot to 720 720 dots to 55 a 2 byte code set writable character 5 1 1 dot to 720 720 dots a Drive Omissible If omitted flash ROM on the CPU board is selected 0 Flash ROM on the CPU board 1 Slot 1 on the PCMCIA board Option 2 Slot 2 on the PCMCIA board ...

Страница 66: ... box in the horizontal direction bb No of dots from the character string area to the box in the vertical direction aa 01 to 99 in units of dots bb 01 to 99 in units of dots C aa Stroked out character aa No of dots from the character string area to the end of the stroke aa 01 to 99 in units of dots Descriptions in parentheses are omissible If omitted it is the character magnification the larger one...

Страница 67: ... to the left q Designates the character position 1 Left 2 Center 3 Right 4aaaa Equal space aaaa X direction of character string area 0050 to 1040 in 0 1 mm units B SX4 0050 to 1280 in 0 1 mm units B SX5 5aaaabbbcc Automatic line feed aaaa X direction of character string area 0050 to 1040 in 0 1 mm units B SX4 0050 to 1280 in 0 1 mm units B SX5 bbb Line feed length 010 to 500 in 0 1 mm units cc Num...

Страница 68: ...he print origin of coordinates must be set so that the character drawing result will be within the effective print area set by the Label Size Set Command ESC D Label Paper feed direction 0 X Y Paper feed direction 0 X Y Backing paper Effective print length Effective print width Effective print width Origin of coordinates 0 0 Origin of coordinates 0 0 Print origin of coordinates Print origin of coo...

Страница 69: ... 0 3 ips 30 0 3 ips 79 0 3 ips 23 0 Label Min 6 0 21 4 23 0 6 ips 91 0 6 ips 30 0 6 0 21 4 23 0 5 ips 87 0 5 ips 23 0 10 ips NOTE 1 10 ips NOTE 1 8 ips 98 0 8 ips 23 0 Max 1496 0 1492 0 1496 0 1492 0 3 ips 28 0 3 ips 28 0 Tag Min 8 0 23 4 6 ips 28 0 8 0 23 4 5 ips 28 0 10 ips NOTE 1 8 ips 36 0 Max 1498 0 1498 0 1498 0 1498 0 NOTE 1 The use of the rotary cutter at 10 ips is not supported for the B ...

Страница 70: ... proportional spacing Horizontal magnification Point of origin Point of origin of next char Relationship between drawing coordinates and magnification 4 Type of font A Times Roman B Times Roman C Times Roman D Times Roman E Times Roman F Times Roman G Helvetica H Helvetica I Helvetica J Helvetica K Helvetica L Helvetica M Presentation N Letter Gothic O Prestige Elite P Prestige Elite Q Courier R C...

Страница 71: ... to character space is specified drawing will take place according to the value obtained by adding the character spacing proportional spacing to the specified value 6 Rotational angles of a character and character string 01 12 23 and 30 are available only when the font type is r Specifying any font other than r results in an error Point of origin Horizontal spacing proportional spacing Horizontal ...

Страница 72: ...check digit of a data row is calculated and only the check digit is drawn When the data includes any data other than the numerals drawing is not performed When the font type is r the check digit cannot be added DBP Modulus 10 is Modulus 10 for Deutsche Bundespost Postdienst only 0 90 Horizontally bold Vertically bold Vertically horizontally bold Horizontally bold Vertically bold Vertically horizon...

Страница 73: ...s are selected and calculated for incrementing decrementing and then are returned to the previous position to draw the data Example of increment decrement calculation Initial value 00000 A0A0A 7A8 9 A2A0A INC DEC 1 1 3 3 1st label 00000 A0A0A 7A8 9 A2A0A 2nd label 00001 A0A1A 7A9 2 A1A7A 3rd label 00002 A0A2A 7A9 5 A1A4A 4th label 00003 A0A3A 7A9 8 A1A1A 5th label 00004 A0A4A 8A0 1 A0A8A 11 Zero s...

Страница 74: ...acter to character space is set to 0 the field is not drawn The same previous field is not drawn When 01 12 23 or 30 is specified for the rotational angles of a character and character string the alignment setting Center Right Equal space or Automatic line feed is ignored 13 Data string to be printed Drawing data can be programmed by designating the number of digits after the symbol Up to 255 digi...

Страница 75: ... field No 1 is designated ESC PC02 03 LF NUL Link field No 3 is designated ESC PC03 04 LF NUL Link field No 4 is designated ESC XB01 03 04 LF NUL Link fields No 3 and No 4 are designated ESC PC04 02 LF NUL Link field No 2 is designated ESC PC05 03 LF NUL Link field No 3 is designated ESC PC06 04 LF NUL Link field No 4 is designated ESC XB02 03 04 LF NUL Link fields No 3 and No 4 are designated Des...

Страница 76: ...crement fields exceeds 32 drawing will take place without incrementing decrementing any excessive field The field to be incremented or decremented is incremented or decremented until the Image Buffer Clear Command ESC C is transmitted Example 1 Format Command Increment character string No 001 1 2 Format Command No incrementing for character string No 002 3 Format Command Increment character string...

Страница 77: ...matic field clear is not performed between the Clear Command ESC C and Issue Command ESC XS the fixed data may be drawn using the same character string number In this case the Format Command and Data Command should be sent alternately After the Issue Command is sent the fields with the same character string number are automatically cleared until the Clear Command is sent 5 The link field designati...

Страница 78: ...LF NUL ESC PC001 0200 0125 1 1 C 00 B LF NUL ESC PC002 0650 0550 2 2 G 33 B 0000000001 LF NUL ESC RC001 Sample LF NUL ESC RC002 001 LF NUL ESC XS I 0002 0002C3000 LF NUL 12 5 mm S a m p l e 55 0 mm 20 0 mm 65 0 mm Effective print area Origin 0 0 1 A B C D 30 0 mm ...

Страница 79: ... B 01 02 LF NUL ESC PV01 0650 0550 0200 0150 B 33 B 02 LF NUL ESC XB01 0200 0550 3 1 03 03 08 08 03 0 0150 01 02 LF NUL ESC RC S LF 001 LF NUL ESC XS I 0002 0002C3000 LF NUL 30 0 mm 55 0 mm 20 0 mm 65 0 mm Effective print area Origin 0 0 2 S 0 0 1 ...

Страница 80: ...LF NUL ESC PC000 0200 0125 1 1 W 00 B LF NUL ESC PC001 0200 0300 1 1 W 01 B LF NUL ESC RC000 AB LF NUL ESC RC001 AB LF NUL ESC XS I 0002 0002C3000 LF NUL 12 5 mm 30 0 mm 20 0 mm Effective print area Origin 0 0 3 ...

Страница 81: ... mm units dddd D Character width 0020 to 0850 in 0 1 mm units eeee D Height of the character 0020 to 0850 in 0 1 mm units f Type of font A TEC FONT1 Helvetica bold B TEC FONT1 Helvetica bold proportional E Price Font 1 F Price Font 2 G Price Font 3 H DUTCH801 Bold Times Roman Proportional I BRUSH738 Regular Pop Proportional J GOTHIC725 Black Proportional ghhh Fine adjustment of character to charac...

Страница 82: ...aracter aa No of dots from the character string area to the end of the stroke aa 01 to 99 in units of dots Descriptions in parentheses are omissible If omitted it is character size the larger character width or height 8 dots Mk Type of the check digit to be attached Omissible If omitted the check digit is not drawn k Type of check digit 0 Modulus 10 Draws data and check digit 1 Modulus 43 Draws da...

Страница 83: ...er 3 Right 4aaaa Equal space aaaa X direction of character string area 0050 to 1040 in 0 1 mm units B SX4 0050 to 1280 in 0 1 mm units B SX5 ppp ppp Data string to be printed Omissible Max 255 digits qq1 qq2 qq3 qq20 Link field No Omissible 01 to 99 1 to 99 can also be used Up to 20 fields can be designated using commas ...

Страница 84: ... name Gdyhp_rg ttf 11 GilliesGotDBol File name Gilli_bd ttf 12 GilliesGotLig File name Gilli_lt ttf 13 NimbusSanNovTUltLigCon File name Nsnct_ul ttf 14 Ryahd File name ryahd ttf 15 Ryahd Bold File name ryahdbd ttf 16 CG Triumvirate File name Trium ttf 17 CG Triumvirate Condensed Bold File name Triumcb ttf 18 Univers Medium File name Tec_uni ttf 19 Univers Bold File name Tec_unib ttf 20 Univers Med...

Страница 85: ...etween characters 000 to 512 in dots jj Rotational angles of a character and character string 00 0 char 0 char string 11 90 char 90 char string 22 180 char 180 char string 33 270 char 270 char string k Character attribution B Black character ppp ppp Data string to be printed Omissible Max 255 digits TrueType fonts are not included in the standard character generator data Therefore they must be ins...

Страница 86: ...t will be within the effective print area set by the Label Size Set Command ESC D Label Paper feed direction 0 X Y Paper feed direction 0 X Y Backing paper Origin of coordinates 0 0 Effective print length Effective print width Effective print length Effective print width Origin of coordinates 0 0 Print direction Printing bottom first Print direction Printing top first Print origin of coordinates P...

Страница 87: ...3 ips 79 0 3 ips 30 0 3 ips 79 0 3 ips 23 0 Label Min 6 0 21 4 23 0 6 ips 91 0 6 ips 30 0 6 0 21 4 23 0 5 ips 87 0 5 ips 23 0 10 ips NOTE 1 10 ips NOTE 1 8 ips 98 0 8 ips 23 0 Max 1496 0 1492 0 1496 0 1492 0 3 ips 28 0 3 ips 28 0 Tag Min 8 0 23 4 6 ips 28 0 8 0 23 4 5 ips 28 0 10 ips NOTE 1 8 ips 36 0 Max 1498 0 1498 0 1498 0 1498 0 NOTE 1 The use of the rotary cutter at 10 ips is not supported fo...

Страница 88: ... 84 4 Type of font A TEC FONT1 Helvetica bold B TEC FONT1 Helvetica bold proportional E Price font 1 POP font ...

Страница 89: ... 85 F Price font 2 POP font G Price font 3 POP font H DUTCH801 Bold Times Roman Proportional ...

Страница 90: ...izontal spacing proportional spacing determined for each character If character to character space is specified drawing will take place according to the value obtained by adding the character spacing proportional spacing to the specified value When equal space is selected for the alignment the character to character space setting is invalid The horizontal spacing proportional spacing are increased...

Страница 91: ...ter other than CODE39 the drawing is not performed When DBP Modulus 10 is selected the check digit of a data row is calculated and only the check digit is drawn When the data includes any data other than the numerals drawing is not performed DBP Modulus 10 is Modulus 10 for Deutsche Bundespost Postdienst only Origin 0 00 90 11 180 22 270 33 Sample Black characters B A No of dots in the horizontal ...

Страница 92: ...A0A3A 7A9 8 A1A1A 5th label 00004 A0A4A 8A0 1 A0A8A 10 Zero suppression No of zeros to be suppressed 0 1 2 2 3 4 5 Data 0000 0000 0000 0A12 0123 0123 0123 Print 0000 0 00 A12 123 0123 0123 The leading zero s in a data row is replaced by a space s according to the designated number of digits However if the number of digits to be suppressed is greater than the data row the data row will be drawn wit...

Страница 93: ...d Designating the link field No Data Command ESC RV A LF B LF ABCD LF 001 LF NUL Link field No 4 Link field No 3 Link field No 2 Link field No 1 Notes 1 The check digit attachment increment decrement and zero suppress processes are performed according to the following priority If any of the conditions are improper no drawing will take place For example the zero s is replaced by a space s as a resu...

Страница 94: ... AB 7 Data Command Character string No 03 0100 8 Issue Command 2 labels 9 Issue Command 1 label 10 Image Buffer Clear Command 11 Data Command Character string No 02 00000 12 Issue Command 1 label 3 The Outline Font Format Command may be connected to the Bit Map Font Format Command when transmitted ESC PC001 0100 0150 1 1 A 00 B LF C002 0350 0180 1 1 A 00 B LF C005 0200 0300 25 2 C 05 00 B 00000000...

Страница 95: ...fine adjustment the outline font is not painted properly Program the fine adjustment value so that characters will not overlap Also when drawings such as lines or characters are on the outline font drawing position the outline font is not painted properly For font types A and B the fine adjustment value should be set so that other drawings do not overlap the area in which the outline font is to be...

Страница 96: ...F NUL ESC PV01 0200 0125 0100 0100 B 00 B LF NUL ESC PV02 0650 0550 0200 0150 B 33 B 0000000001 LF NUL ESC RV01 Sample LF NUL ESC RV02 001 LF NUL ESC XS I 0002 0002C3000 LF NUL Origin 0 0 12 5 mm S a m p l e 55 0 mm 20 0 mm 65 0 mm Effective print area 1 A B C D 30 0 mm ...

Страница 97: ... B 01 02 LF NUL ESC PV01 0650 0550 0200 0150 B 33 B 02 LF NUL ESC XB01 0200 0550 3 1 03 03 08 08 03 0 0150 01 02 LF NUL ESC RV S LF 001 LF NUL ESC XS I 0002 0002C3000 LF NUL 2 30 0 mm 55 0 mm 20 0 mm 65 0 mm Effective print area Origin 0 0 S 0 0 1 ...

Страница 98: ...mber 00 to 31 bbbb Print origin of X coordinate of the bar code Fixed as 4 digits in 0 1 mm units cccc Print origin of Y coordinate of the bar code 4 or 5 digits in 0 1 mm units d Type of bar code 0 JAN8 EAN8 5 JAN13 EAN13 6 UPC E 7 EAN13 2 digits 8 EAN13 5 digits 9 CODE128 with auto code selection A CODE128 without auto code selection C CODE93 G UPC E 2 digits H UPC E 5 digits I EAN8 2 digits J E...

Страница 99: ... digit auto attachment 1 is effective ff 1 module width 01 to 15 in dots k Rotational angle of bar code 0 0 1 90 2 180 3 270 llll Height of the bar code 0000 to 1000 in 0 1 mm units For the Customer bar code POSTNET RMC4SCC KIX CODE the height of the long bar is specified mnnnnnnnnnn Increment decrement Omissible If omitted incrementing decrementing is not performed m Indicates whether to incremen...

Страница 100: ...ries depending on the type of bar code tt1 tt2 tt3 tt20 Link field No Omissible 01 to 99 1 to 99 can also be used Up to 20 fields can be designated using commas Omissible parameters such as Increment decrement Selection of print or non print of numerals under bars and No of zeros to be suppressed cannot be set when the postal code Customer bar code POSTNET RM4SCC KIX CODE is selected ...

Страница 101: ... Industrial 2 of 5 a MATRIX 2 of 5 for NEC e Type of check digit 1 Without attaching check digit 2 Check digit check CODE39 Modulus 43 MSI IBM modulus 10 ITF Modulus 10 Industrial 2 of 5 Modulus check character MATRIX 2 of 5 for NEC Modulus check character 3 Check digit auto attachment 1 CODE39 Modulus 43 MSI IBM modulus 10 ITF Modulus 10 Industrial 2 of 5 Modulus check character MATRIX 2 of 5 for...

Страница 102: ...000000 to 9999999999 p Selection of print or non print of numerals under bars Omissible If omitted the numerals under the bars are not printed 0 Non print 1 Print qq No of zeros to be suppressed Omissible If omitted the zero suppression process is not performed 00 to 20 r Designates the attachment of start stop code Omissible If omitted the start stop code is automatically attached T Attachment of...

Страница 103: ...dth 01 to 15 in dots g Rotational angle of bar code 0 0 1 90 2 180 3 270 hhhh Height of the bar code 0000 to 1000 in 0 1 mm units In the case of GS1 DataBar Truncated set a value obtained by multiplying one module width by 13 ijjjjjjjjjj Increment decrement Omissible If omitted incrementing decrementing is not performed i Indicates whether to increment or decrement Increment Decrement jjjjjjjjjj S...

Страница 104: ...string to be printed Omissible Max 126 digits However it varies depending on the type of bar code tt1 tt2 tt3 tt20 Link field No Omissible 01 to 99 1 to 99 can also be used Up to 20 fields can be designated using commas ...

Страница 105: ...code 4 or 5 digits in 0 1 mm units d Type of bar code Q Data Matrix Two dimensional code ee ECC type 00 ECC0 01 ECC50 04 ECC50 05 ECC50 06 ECC80 07 ECC80 08 ECC80 09 ECC100 10 ECC100 11 ECC140 12 ECC140 13 ECC140 14 ECC140 20 ECC200 ff 1 cell width 00 to 99 in dots gg Format ID 01 Format ID 1 02 Format ID 2 03 Format ID 3 04 Format ID 4 05 Format ID 5 06 Format ID 6 When ECC200 is designated as EC...

Страница 106: ...8 26 12 36 12 36 16 48 16 When this parameter is omitted the number of cells is automatically set Also when any data other than the above values are designated for the number of cells in the X and Y directions the number of cells are automatically set Jkkllmmmnnn Connection setting Omissible No connection if this parameter is omitted kk Code number 01 to 16 ll No of divided codes 02 to 16 mmm ID n...

Страница 107: ...or 5 digits in 0 1 mm units d Type of bar code P PDF417 Two dimensional code ee Security level 00 Level 0 01 Level 1 02 Level 2 03 Level 3 04 Level 4 05 Level 5 06 Level 6 07 Level 7 08 Level 8 ff 1 module width 01 to 10 in dots gg No of columns strings 01 to 30 h Rotational angle of bar code 0 0 1 90 2 180 3 270 iiii Bar height 0000 to 0100 in 0 1 mm units jjj jjj Data string to be printed Omissi...

Страница 108: ... Print origin of Y coordinate of the bar code 4 or 5 digits in 0 1 mm units d Type of bar code X MicroPDF417 Two dimensional code ee Security level 00 Fixed ff 1 module width 01 to 10 in dots gg No of columns rows 00 to 38 h Rotational angle of bar code 0 0 1 90 2 180 3 270 iiii Bar height 0000 to 0100 in 0 1 mm units jjj jjj Data string to be printed Omissible Max 366 digits kk1 kk2 kk3 kk20 Link...

Страница 109: ...15 20 33 56 82 16 23 38 64 93 17 26 43 72 105 18 6 6 10 14 19 8 10 18 26 20 10 15 26 38 21 12 20 34 49 22 3 15 27 46 67 23 20 39 66 96 24 26 54 90 132 25 32 68 114 167 26 38 82 138 202 27 44 97 162 237 28 4 8 14 20 29 6 13 22 32 30 8 20 34 49 31 10 27 46 67 32 12 34 58 85 33 4 15 45 76 111 34 20 63 106 155 35 26 85 142 208 36 32 106 178 261 37 38 128 214 313 38 44 150 250 366 for parameter 00 to 0...

Страница 110: ...to 52 in dots g Selection of mode M Manual mode A Automatic mode h Rotational angle of the bar code 0 0 1 90 2 180 3 270 Mi Selection of model Omissible If omitted Model 1 is automatically selected i 1 Model 1 2 Model 2 Kj Mask number Omissible If omitted the number is automatically set j 0 to 7 Mask number 0 to 7 8 No mask Jkkllmm Connection setting Omissible No connection if this parameter is om...

Страница 111: ...fication setting is set to TYPE2 Special specification in the system mode Omitted Mode 2 or Mode 3 0 Mode 2 or Mode 3 1 Mode 4 2 Mode 2 3 Mode 3 4 Mode 4 5 Mode 2 or Mode 3 6 Mode 6 7 Mode 2 or Mode 3 8 Mode 2 or MODE 3 9 Mode 2 or MODE 3 Mode 2 or Mode 3 should be determined depending on the country code of the data command When the country code is 840 Mode 2 should be selected For other codes th...

Страница 112: ...blank code areas created after the characters are encoded should all be filled with ECC characters ff 1 cell width 00 to 99 in dots g No of character bits 0 Set automatically A 8 bits Designates how many bits are used for representing a character When 0 is designated the optimal value is automatically set according to data h Rotational angle of the bar code 0 0 1 90 2 180 3 270 Ciijj No of code ch...

Страница 113: ... 1 mm units d Type of bar code r RFID data write Aeee Address where the data is written Omissible 000 to 999 Designates the address where data starts to be written When omitted this parameter will be set to 18 for ISO18000 6B tag or 0 for other tag types Mg Format of U Code V1 19 Omissible 0 SGTIN 96 format 1 SSCC96 format 2 Reserved When the format of U Code V1 19 is designated the specified addr...

Страница 114: ...4 SGLN 195 25 GRAI 170 26 GIAI 202 Gk Data type Omissible 0 No conversion of data When omitted 1 Conversion to binary 2 Conversion to hexadecimal 3 No conversion of data with separator 4 Conversion to binary with separator 5 Conversion to hexadecimal with separator When a separator is to be used use a colon 3AH a separator between the blocks in the data For example RB00 UII Code0123 TIDx0123 0000 ...

Страница 115: ... 02 Unlocked Locked Unlocked Unlocked Unlocked 03 Locked Locked Unlocked Unlocked Unlocked 04 Unlocked Unlocked Locked Unlocked Unlocked 05 Locked Unlocked Locked Unlocked Unlocked 06 Unlocked Locked Locked Unlocked Unlocked 07 Locked Locked Locked Unlocked Unlocked 08 Unlocked Unlocked Unlocked Locked Unlocked 09 Locked Unlocked Unlocked Locked Unlocked 10 Unlocked Locked Unlocked Locked Unlocked...

Страница 116: ...57 Permanent lock Unlocked Unlocked Permanent lock Permanent lock 58 Unlocked Permanent lock Unlocked Permanent lock Permanent lock 59 Permanent lock Permanent lock Unlocked Permanent lock Permanent lock 60 Unlocked Unlocked Permanent lock Permanent lock Permanent lock 61 Permanent lock Unlocked Permanent lock Permanent lock Permanent lock 62 Unlocked Permanent lock Permanent lock Permanent lock P...

Страница 117: ...ck designation Effective only when the Hibiki tag is used for the B SX704 RFID U2 R Designates an area lock type Area lock type can be specified for up to eight areas continuously For example Q1100000 Q4101010 Q5100010 which indicates Bank1 Read lock Bank4 Read lock Write lock Password read write lock Bank5 Read lock Password read write lock z Area bank designation 1 to 8 1 Bank1 EPC UII bank 2 Ba...

Страница 118: ...password to access and write a tag of which user block is write locked Up to five user blocks can be specified continuously For example X4AABBCCDD X5BBCCDDEE X6CCDDEEFF g Designates a user area bank 4 to 8 4 Bank4 User block 1 5 Bank5 User block 2 6 Bank6 User block 3 7 Bank7 User block 4 8 Bank8 User block 5 hhhhhhhh User block access password Fixed to 8 digit hexadecimal number 00000000 to FFFFF...

Страница 119: ...D data read Neee Number of bytes to be read Omissible 0001 to 4096 When omitted the number of bytes specified for the tag type being used will be designated Afff Address where the data is read Omissible 000 to 999 Designates the address where data starts to be read When omitted this parameter will be set to 18 for ISO18000 6B tag or 0 for other tag types Tgg Tag type Omissible 00 None 11 I Code 12...

Страница 120: ...is parameter is effective only for EPC Class 1 Generation 2 tag type Xjkkkkkkkk User block access password execution setting Effective only when the Hibiki tag is used for the B SX704 RFID U2 R Designates a password to access and read a tag of which user block is read locked Up to five user blocks can be specified continuously For example X4AABBCCDD X5BBCCDDEE X6CCDDEEFF j Designates a user area b...

Страница 121: ...rinter status Status type 34H Indicates the end of an RFID read and issue 3XH 3XH 3XH Remaining count 3XH Remaining issue count XXH Tag type XXH 30H30H RFID read failed 31H31H I Code 31H32H Tag it 31H33H C220 31H34H ISO15693 31H35H C210 31H36H C240 31H37H C320 32H31H EPC Class 0 32H32H EPC Class 1 32H33H ISO18000 6B 32H34H EPC Class 1 Generation 2 XXH Length XXH RFID data length XXH XXH XXH RFID d...

Страница 122: ...10 0 Max 104 0 128 0 Effective print length 3 ips 79 0 3 ips 30 0 3 ips 79 0 3 ips 23 0 Label Min 6 0 21 4 23 0 6 ips 91 0 6 ips 30 0 6 0 21 4 23 0 5 ips 87 0 5 ips 23 0 10 ips NOTE 1 10 ips NOTE 1 8 ips 98 0 8 ips 23 0 Max 1496 0 1492 0 1496 0 1492 0 3 ips 28 0 3 ips 28 0 Tag Min 8 0 23 4 6 ips 28 0 8 0 23 4 5 ips 28 0 10 ips NOTE 1 8 ips 36 0 Max 1498 0 1498 0 1498 0 1498 0 NOTE 1 The use of the...

Страница 123: ...1 MSI 2 Interleaved 2 of 5 3 CODE39 standard 4 NW7 5 JAN13 EAN13 6 UPC E 7 EAN13 2 digits 8 EAN13 5 digits 9 A CODE128 B CODE39 Full ASCII C CODE93 G UPC E 2 digits H UPC E 5 digits I EAN8 2 digits J EAN8 5 digits K UPC A L UPC A 2 digits ...

Страница 124: ... M UPC A 5 digits N UCC EAN128 O Industrial 2 of 5 P PDF417 Q Data Matrix R Customer bar code S Highest priority customer bar code T QR code U POSTNET V RM4SCC W KIX code X MicroPDF417 Y CP Code Z MaxiCode ...

Страница 125: ...CODE93 CODE128 with auto code selection or UCC EAN128 the check digit will always be attached regardless of the designation of the type of check digit g If the type of bar code is JAN EAN or UPC the designation of no check digit attachment automatically assumes the check digit check h DBP Modulus 10 is Modulus 10 for Deutsche Bundespost Postdienst only 5 Bar width space width and character to char...

Страница 126: ...s 6 modules Bar Space Bar Space Bar Space Bar Space Bar Space Bar Space JAN EAN UPC 4 8 12 16 CODE93 3 6 9 12 CODE128 EAN128 3 6 9 12 PDF417 3 6 9 12 15 18 MicroPDF417 2 4 6 8 10 12 Type of bar code Narrow Wide Character to character Bar Space Bar Space space MSI 3 3 8 8 0 ITF 3 3 8 8 0 CODE39 3 3 8 8 3 NW7 3 3 8 8 3 Industrial 2 of 5 3 3 8 0 3 MATRIX 2 of 5 3 3 8 8 3 When NW7 is used transmission...

Страница 127: ...a two dimensional code is not drawn However the bar code printed on the previous label is cleared In the case of a postal code 6 Rotational angle of bar code 0 90 180 270 0 90 180 270 1 cell width 1 cell width 1 module width Point of origin Point of origin ...

Страница 128: ...idirectional GS1 DataBar Truncated GS1 DataBar Stacked GS1 DataBar Stacked Omnidirectional Height Height Height Height Height The height of the bottom row is the same as the specified height Height Height Height The height of the bottom row is 7 5 of the specified height ...

Страница 129: ...umerals are are not provided under bars according to the parameter for print non print of numerals under bars The contents of numerals under bars to be printed vary according to the type of bar code The character set of numerals under bars is OCR B Such numerals are enlarged or reduced only horizontally according to the width of the bar code They are drawn vertically in the fixed one magnification...

Страница 130: ...ype of bar code is CODE39 and NW7 y Where the parameter is designated the program will not check if the stop code and the start code are attached to the print data to be sent y When the parameter is omitted in the case of CODE39 and NW7 a start stop code will be attached The code to be added is in the case of CODE39 and a in the case of NW7 y For details refer to chapter 15 AUTOMATIC ADDING OF STA...

Страница 131: ...d Up to 40 digits including letters numerals and symbols are possible Only the numerals are selected and calculated for incrementing decrementing and then are returned to the previous position to draw the data Example of increment decrement calculation Initial value 00000 A0A0A 7A8 9 A2A0A INC DEC 1 1 3 3 1st label 00000 A0A0A 7A8 9 A2A0A 2nd label 00001 A0A1A 7A9 2 A1A7A 3rd label 00002 A0A2A 7A9...

Страница 132: ...ating the number of digits after the symbol The maximum number of digits to be printed varies according to the types of bar codes For codes refer chapter 13 BAR CODE TABLE 14 Link field No The link field No can be programmed by designating it after the symbol After the link field No is designated using the Format Command the data string are linked by the Link Field Data Command to draw an image Up...

Страница 133: ...ever it may vary according to the error conditions ECC type Error Correction Ability Overhead by ECC ECC0 0 ECC50 25 ECC80 33 ECC100 50 ECC140 75 ECC200 Approx 30 d Format ID Data Matrix can handle all codes including alphanumerics symbols and Kanji Since data compression rate varies according to codes a code to be used is designated using the format ID Format ID Code Details 1 Numerics 0 to 9 spa...

Страница 134: ...of digits in cell units see the next page f Connection setting The connection setting is used to comprise data with a set of two dimensional codes when the data cannot be expressed with a two dimensional code When three two dimensional codes are used to comprise data identification information of 1 3 2 3 and 3 3 is inserted into each two dimensional code The ID number is programmed to include a pr...

Страница 135: ... 115 76 50 78 52 34 65 43 28 47 31 20 17 11 7 25 25 140 93 61 97 65 42 82 54 36 60 40 26 24 16 10 27 27 168 112 73 118 78 51 100 67 44 73 49 32 30 20 13 29 29 197 131 86 140 93 61 120 80 52 88 59 38 38 25 16 31 31 229 153 100 164 109 72 141 94 62 104 69 45 46 30 20 33 33 264 176 115 190 126 83 164 109 72 121 81 53 54 36 24 35 35 300 200 131 217 145 95 188 125 82 140 93 61 64 42 28 37 37 339 226 14...

Страница 136: ...27 84 40 40 228 169 112 44 44 288 214 142 48 48 348 259 172 52 52 408 304 202 64 64 560 418 278 72 72 736 550 366 80 80 912 682 454 88 88 1152 862 574 96 96 1392 1042 694 104 104 1632 1222 814 120 120 2000 1573 1048 132 132 2000 1954 1302 144 144 2000 2000 1556 Rectangular code ECC200 Symbol size Numeric capacity Alphanum capacity 8 bit byte Row Col capacity 8 18 10 6 3 8 32 20 13 8 12 26 32 22 14...

Страница 137: ...cause the number of rows exceeds 90 when the number of columns becomes small When the PDF417 is used the number of rows of symbols is limited from 3 to 90 For the MicroPDF417 not only the number of columns data strings but also the number of rows data lines can be designated When these are to be designated see the table on page 100 Note that the max number of digits for the set parameter gg varies...

Страница 138: ...g pattern for the mask number upon the module pattern When the mask number is set to 8 masking is not performed When the parameter is omitted the most appropriate mask number is automatically selected to perform masking h Connection setting For QR code data can be divided into several codes Even though there is only a narrow print space the code can be entered in the space by dividing the code The...

Страница 139: ...used for one block and the block set forms the CP code The numbers of characters in the X and Y directions can be set by the user If 0 is specified the printer automatically sets the smallest code size in which data set by the user can be contained The rectangular code can be specified The value for the Y direction must be smaller than the X direction The number of cells for the code is as follows...

Страница 140: ...y issue is enabled it may take much time to issue RFID tag paper because the printer will feed the paper backward when an error occurs Therefore the total throughput could be higher when the print condition is set so that the on the fly issue is not performed RFID data is written prior to printing and print speed is 10 inches sec g U Code V1 19 and EPC format When U Code V1 19 or EPC format is des...

Страница 141: ...etting may not be effective for some of the EPC Class 1 Generation 2 tags k Access to the password protected tags When Access to the password protected tags is designated for an RFID write the printer prints the void pattern if an access password for the RFID write does not match with the access password designated Note that data can be written even onto password protected tags when a designation ...

Страница 142: ...ted can be drawn If the total bit map font outline font and bar code increment decrement fields exceeds 32 drawing will take place without incrementing decrementing any excessive field The field to be incremented or decremented is incremented or decremented until the Image Buffer Clear Command ESC C is transmitted Example c Format Command Increment bar code No 01 1 d Format Command Increment bar c...

Страница 143: ...rmed between the Clear Command ESC C and Issue Command ESC XS the fixed data may be drawn using the same bar code number In this case the Format Command and Data Command should be sent alternately After the Issue Command is sent the fields with the same bar code number are automatically cleared until the Clear Command is sent 5 The link field designation is cleared by omitting the link field desig...

Страница 144: ...25 3 1 03 03 08 08 03 0 0150 12345 LF NUL ESC XB02 0830 0550 3 1 02 04 07 08 04 3 0150 0000000000 1 00 N LF NUL ESC RB02 ABC LF NUL ESC XS I 0002 0002C3000 LF NUL 12 5 mm 55 0 mm 20 0 mm 83 0 mm Effective print area Origin 0 0 15 0 mm 15 0 mm 1 ...

Страница 145: ... B 01 02 LF NUL ESC PV01 0650 0550 0200 0150 B 33 B 02 LF NUL ESC XB01 0200 0550 3 1 03 03 08 08 03 0 0150 01 02 LF NUL ESC RB S LF 001 LF NUL ESC XS I 0002 0002C3000 LF NUL Effective print area 30 0 mm 55 0 mm 20 0 mm 65 0 mm Origin 0 0 2 S 0 0 1 ...

Страница 146: ...B01 0200 0125 P 04 02 03 0 0010 LF NUL ESC XB02 0830 0550 Q 08 03 05 3 LF NUL ESC RB01 PDF417 LF NUL ESC RB02 Data Matrix LF NUL ESC XS I 0002 0002C3000 LF NUL Effective print area 20 0 mm Origin 0 0 3 12 5 mm 55 0 mm 83 0 mm ...

Страница 147: ...e example is deleted Explanation 1 Link field data string After the link field No is designated in the Format Command data strings are linked using the Link Field Data Command to draw an image Up to 255 digits of data strings can be linked However when the font type is r 51 52 53 54 or 55 only up to 127 digits can be linked When the number of digits exceeds the maximum value excess data will be di...

Страница 148: ...er 1 23ABC 31h 32h 33h 41h 42h 43h 1 2 3 A B C 4 To mix Kanji and writable characters on the same field The character code should be specified in the manner described below c GB18030 Chinese characters 20h to A0h Half width character Other codes GB18030 A Kanji Writable character D6h D0h B9h FAh FAh A1h Writable character B Kanji Half width character ABC abc Writable character D6h D0h 41h 42h 43h ...

Страница 149: ... PC001 0200 0125 1 1 C 00 B LF NUL ESC PC002 0650 0550 2 2 G 33 B 0000000001 LF NUL ESC RC001 Sample LF NUL ESC RC002 001 LF NUL ESC XS I 0002 0002C3000 LF NUL 55 0 mm 12 5 mm 20 0 mm 65 0 mm Origin 0 0 Effective print area Sample 1 ...

Страница 150: ... B 01 02 LF NUL ESC PV01 0650 0550 0200 0150 B 33 B 02 LF NUL ESC XB01 0200 0550 3 1 03 03 08 08 03 0 0150 01 02 LF NUL ESC RC S LF 001 LF NUL ESC XS I 0002 0002C3000 LF NUL Effective print area 2 30 0 mm 55 0 mm 20 0 mm 65 0 mm Origin 0 0 S 0 0 1 ...

Страница 151: ... LF NUL ESC PC000 0200 0125 1 1 X 00 B LF NUL ESC PC001 0200 0300 1 1 X 01 B LF NUL ESC RC000 AB LF NUL ESC RC001 AB LF NUL ESC XS I 0002 0002C3000 LF NUL 12 5 mm 30 0 mm 20 0 mm Effective print area Origin 0 0 3 ...

Страница 152: ...eted Explanation 1 Link field data string After the link field No is designated in the Format Command data strings are linked using the Link Field Data Command to draw an image Up to 255 digits of data strings can be linked Data exceeding the max number of digits will be discarded Up to 99 data strings can be linked Up to 2048 bytes can be used as the command length ESC to NUL of the Link Field Da...

Страница 153: ...1 0200 0125 0100 0100 B 00 B LF NUL ESC PV02 0650 0550 0200 0150 B 33 B 0000000001 LF NUL ESC RV01 Sample LF NUL ESC RV02 001 LF NUL ESC XS I 0002 0002C3000 LF NUL 55 0 mm 12 5 mm 20 0 mm 65 0 mm Origin 0 0 Effective print area Sample 1 ...

Страница 154: ... B 01 02 LF NUL ESC PV01 0650 0550 0200 0150 B 33 B 02 LF NUL ESC XB01 0200 0550 3 1 02 02 06 06 02 0 0150 01 02 LF NUL ESC RC S LF 001 LF NUL ESC XS I 0002 0002C3000 LF NUL 30 0 mm 55 0 mm 20 0 mm 65 0 mm Effective print area Origin 0 0 2 S 0 0 1 ...

Страница 155: ...pecified bar code number e g ESC RB00 LF NUL the previous data string of the same bar code number No 00 in the case of the above example is deleted In the case of the bar code type of which data length is specified e g Binary mode of QR code the previously drawn bar code cannot be deleted just by setting the data length to zero To delete the previous bar code be sure to send the command without en...

Страница 156: ...it byte Numeric capacity Alphanum capacity 8 bit byte Row Col capacity capacity capacity capacity capacity 9 9 3 2 1 11 11 12 8 5 1 1 13 13 24 16 10 10 6 4 4 3 2 1 1 15 15 37 25 16 20 13 9 13 9 6 8 5 3 17 17 53 35 23 32 21 14 24 16 10 16 11 7 2 1 1 19 19 72 48 31 46 30 20 36 24 16 25 17 11 6 4 3 21 21 92 61 40 61 41 27 50 33 22 36 24 15 12 8 5 23 23 115 76 50 78 52 34 65 43 28 47 31 20 17 11 7 25 ...

Страница 157: ...27 84 40 40 228 169 112 44 44 288 214 142 48 48 348 259 172 52 52 408 304 202 64 64 560 418 278 72 72 736 550 366 80 80 912 682 454 88 88 1152 862 574 96 96 1392 1042 694 104 104 1632 1222 814 120 120 2000 1573 1048 132 132 2000 1954 1302 144 144 2000 2000 1556 Rectangular code ECC200 Symbol size Numeric capacity Alphanum capacity 8 bit byte Row Col capacity 8 18 10 6 3 8 32 20 13 8 12 26 32 22 14...

Страница 158: ...mber of the code words exceeds 928 or when the number of rows exceeds 90 the symbols are not drawn For the MicroPDF417 the numbers of rows and columns can be specified The maximum number of digits varies according to the setting In the case of PDF417 Extended Alphanumeric Compaction EXC mode 1850 digits Binary ASCII Plus mode 1108 digits Numeric compaction mode 2000 digits In the case of MicroPDF4...

Страница 159: ...6 8 06 14 7 12 17 07 1 17 10 18 26 08 20 13 22 32 09 24 18 30 44 10 28 22 38 55 11 8 8 14 20 12 11 14 24 35 13 14 21 36 52 14 2 17 27 46 67 15 20 33 56 82 16 23 38 64 93 17 26 43 72 105 18 6 6 10 14 19 8 10 18 26 20 10 15 26 38 21 12 20 34 49 22 3 15 27 46 67 23 20 39 66 96 24 26 54 90 132 25 32 68 114 167 26 38 82 138 202 27 44 97 162 237 28 4 8 14 20 29 6 13 22 32 30 8 20 34 49 31 10 27 46 67 32...

Страница 160: ...ric data continue in CODE A or CODE B a When the numeric data is an even number of digits insert the CODE C character just before the first numeric data b When the numeric data is an odd number of digits insert the CODE C character immediately after the first numeric data f If a control character appears in CODE B a In the subsequent data when a small letter appears before the next control charact...

Страница 161: ...mmand data strings are linked using the Link Field Data Command to draw an image Up to 2000 digits of data strings of Data Matrix and PDF417 can be linked For other bar codes up to 126 digits can be linked The value varies according to the type of bar code When the number of digits exceeds the maximum value excess data will be discarded Up to 99 data strings can be linked Up to 2048 bytes can be u...

Страница 162: ...te varies according to codes the code to be used is designated when the mode is selected Mode Code Details N Numerals 0 to 9 A Alphanumerics symbols A to Z 0 to 9 space B Binary 8 bit 00H to FFH K Kanji Shift JIS JIS hexadecimal If mixed mode is selected up to 200 modes can be selected in a QR code 8 When the automatic mode is selected in the Format Command for a QR code Data to be printed 9 How t...

Страница 163: ...amples of data designation c Alphanumeric mode ABC123 A A B C 1 2 3 Data to be printed Designation of mode d Binary mode 01H 03H 05H B 0 0 0 6 A C E Data to be printed No of data strings Designation of mode e Mixed mode Numeric mode 123456 Kanji mode Kanji data Binary mode a i u e o Alphanumeric mode ABC N 1 2 3 4 5 6 K Kanji data B 0 0 1 0 a i u e o A A B C Designation of mode f Automatic mode Wh...

Страница 164: ...when mode 2 or 3 is selected the printer adds a CR 000000 at the end of the data and the remaining digits will be padded with FSs 011100 When message data exceeding 84 digits is received the excess data will be discarded before drawing a MaxiCode 3 If the message data is less than 93 digits 9 digits 84 digits when mode 4 or 6 is selected the printer adds a CR 000000 at the end of the data and the ...

Страница 165: ...2 02 06 06 02 0 0150 LF NUL ESC XB02 0830 0550 3 1 02 04 07 08 04 3 0150 0000000000 1 00 N LF NUL ESC RB01 12345 LF NUL ESC RB02 ABC LF NUL ESC XS I 0002 0002C3000 LF NUL 20 0 mm 15 0 mm 55 0 mm 12 5 mm 63 0 mm 15 0 mm Origin 0 0 Effective print area 1 ...

Страница 166: ... B 01 02 LF NUL ESC PV01 0650 0550 0200 0150 B 33 B 02 LF NUL ESC XB01 0200 0550 3 1 02 02 06 06 02 0 0150 01 02 LF NUL ESC RB S LF 001 LF NUL ESC XS I 0002 0002C3000 LF NUL Effective print area 30 0 mm 55 0 mm 20 0 mm 65 0 mm Origin 0 0 2 S 0 0 1 ...

Страница 167: ...B01 0200 0125 P 04 02 03 0 0010 LF NUL ESC XB02 0830 0550 Q 08 03 05 3 LF NUL ESC RB01 PDF417 LF NUL ESC RB02 Data Matrix LF NUL ESC XS I 0002 0002C3000 LF NUL Effective print area 20 0 mm Origin 0 0 3 12 5 mm 55 0 mm 83 0 mm ...

Страница 168: ...s 4 Reflective sensor when using a manual threshold value d Issue mode C Batch mode D Strip mode with back feed the strip sensor is valid E Strip mode with back feed the strip sensor is ignored the applicator supports this mode e Issue speed B SX4T B SX5T 3 3 ips 3 3 ips 6 6 ips 5 5 ips A 10 ips 8 8 ips f With without ribbon 0 Without ribbon 1 With ribbon with ribbon saving function 2 With ribbon ...

Страница 169: ...s sent The power should not be turned off then on or the printer should not be placed in a pause reset state before the automatic forward feed since the automatic forward feed is not performed when the paper is fed by turning the power off then on or by pressing the FEED key of the printer in the pause reset state If the paper is fed by pressing the FEED key of the printer during the forward feed ...

Страница 170: ...n 4 Issue mode C Batch mode Cut interval 0 Issue count 3 Automatic forward feed standby is set to OFF in the system mode C Batch mode Cut interval 0 Issue count 3 Automatic forward feed standby is set to ON in the system mode Head position A A B A B C 1 Idling at the home position 2 Prints the 1st label A 3 Prints the 2nd label B 4 Prints the 3rd label C Head position A A B 1 Idling during the for...

Страница 171: ...s used 1 Idling A A A B Head position Cut position 2 Completes printing the 1st label A 3 Feeds the 1st label A to the cut position 4 Cuts the 1st label A 6 Completes printing the 2nd label B 7 Feeds the 2nd label B to the cut position 8 Cuts the 2nd label B B B 9 Feeds back to the home position 5 Feeds back to the home position ...

Страница 172: ...sition Cut position 3 Completes printing the 1st label A 4 Feeds the 1st label A to the cut position 5 Cuts the 1st label A 7 Completes printing the 2nd label B 8 Feeds the 2nd label B to the cut position 9 Cuts the 2nd label B B B 10 Feeds back to the home position 6 Feeds back to the home position 2 Feeds back to the home position 11 After 1 second performs 13 7 mm automatic forward feed ...

Страница 173: ...Cut position 2 Completes printing the 1st label A 3 Starts printing the 2nd label B 4 The 1st label A reaches the cut position and is cut 5 Completes printing the 2nd label B 6 Feeds the 2nd label B to the cut position 7 The 2nd label B reaches the cut position and is cut B B 9 Feeds back to the home position 8 Since non stop cutting is performed paper is fed and stopped over the cut position ...

Страница 174: ...label A 4 Starts printing the 2nd label B 5 The 1st label A reaches the cut position and is cut 6 Completes printing the 2nd label B 7 Feeds the 2nd label B to the cut position 8 The 2nd label B reaches the cut position and is cut B B 10 Feeds back to the home position 2 Feeds back to the home position 11 After 1 second performs 13 7 mm automatic forward feed 9 Since non stop cutting is performed ...

Страница 175: ...1st label A 4 Remove the 1st label A 6 Completes printing the 2nd label B 7 Remove the 2nd label B 9 Completes printing the 3rd label C The next label is not printed until the printed label is removed 2 Feeds back to the home position 5 Feeds back to the home position 8 Feeds back to the home position ...

Страница 176: ...A The PAUSE signal generated from the expansion I O is turned OFF 6 Completes printing the 2nd label B The PAUSE signal generated from the expansion I O is turned ON 7 Remove the 2nd label B The PAUSE signal generated from the expansion I O is turned OFF 9 Completes printing the 3rd label C The PAUSE signal generated from the expansion I O is turned ON When the PAUSE signal generated from the expa...

Страница 177: ...on I O has been installed the printer issues the specified number of labels while the PAUSE signal generated from the expansion I O is off 4 If the issue count is set to 2 or more to issue labels when the expansion I O has not been installed the specified number of labels is issued A B C Head position Strip position 1 Idling 3 Completes printing the 1st label A 5 Completes printing the 2nd label B...

Страница 178: ...s When the parameter in the Issue Command is set to Without ribbon saving function or the ribbon saving system is set in the system mode so that it is not used no ribbon saving will take place NOTES 1 To use the ribbon saving function it is necessary to select the parameter depending on the head lever position This selection is performed by the parameter settings in the system mode Head lever posi...

Страница 179: ...head is lowered to at least 50 of the label pitch length Solenoid OFF Correction Ribbon saving area Paper feed direction Ribbon saving area Correction Paper feed direction A B C D E Printing area Correct so that the head is lowered to at least 50 of the label pitch length Solenoid OFF Ribbon saving area A B C D E Printing area Ribbon saving area ...

Страница 180: ...g Paper feed direction 0 X Y S a m p l e Effective print length Origin of coordinates 0 0 Label Backing paper Effective print width Label pitch Paper feed direction 0 X Y Labels Tags S a m p l e Black mark Back side of print Effective print length Effective print width Tag pitch Tag Paper feed direction 0 X Y Effective print length Origin of coordinates 0 0 Label Backing paper Effective print widt...

Страница 181: ...ck side of print Label Backing paper Effective print width Label pitch Paper feed direction 0 X Y Effective print length Labels Tags Black mark Back side of print Effective print length Origin of coordinates 0 0 Label Backing paper Effective print width Label pitch Paper feed direction Labels 0 X Y Effective print length Effective print width Tag pitch Tag Paper feed direction Origin of coordinate...

Страница 182: ...ne label Do not change the parameter for status response no status response during printing Otherwise the status response may not be performed properly Examples ESC D0762 0820 0732 LF NUL ESC T11C30 LF NUL ESC C LF NUL ESC PC001 0150 0410 1 1 A 00 B LF NUL ESC RC001 Sample LF NUL ESC XS I 0004 0011C8201 LF NUL Issue count 4 pieces Cut interval 1 piece Paper Tag paper Reflective sensor used Issue m...

Страница 183: ...tected the value to stop at the home position of each label between the head and the sensor is set again The paper is moved in the above state Stop position after feeding one label However an error will result when feed jam conditions are met Sensor A B C Stop position Paper feed direction A B C Stop position Sensor D 15 mm after detection of gap between B and C A B C Stop position 77 mm 92 mm Sen...

Страница 184: ... ips 8 8 ips e With without ribbon 0 Without ribbon 1 With ribbon with ribbon saving function 2 With ribbon without ribbon saving function Explanation 1 Type of sensor c No sensor Feeding takes place according to the parameter designated by the Label Size Set Command d Reflective sensor Feeding takes place according to the parameter designated by the Label Size Set Command However the black mark p...

Страница 185: ... feed mode only Non cut is selected in the strip mode If no subsequent command is received from the PC for 1 second when the automatic forward feed is set to ON the printer automatically performs an approximately 13 7 mm forward feed When the Feed Command is received in the forward feed standby state the printer performs a reverse feed to the original position For notes refer to the section regard...

Страница 186: ...paper Head position Cut position 1 Place paper 3 Feeds to the cut position 4 Cuts unnecessary paper 5 Feeds back to the home position 6 After 1 second performs 13 7 mm automatic forward feed 2 Completes a feed Completes feeding to the top of paper Head position Cut position 1 Place paper 3 Feeds to the cut position 4 Cuts unnecessary paper 5 Since non stop cutting is performed paper is fed and sto...

Страница 187: ...feed is performed 3 Starts a feed 4 Completes a feed Completes feeding to the top of form and stops 2 Completes a feed Completes feeding to the top of paper Head position Cut position 1 Place paper 3 Feeds to the cut position 4 Cuts unnecessary paper 6 Feeds back to the home position 7 After 1 second performs 13 7 mm automatic forward feed 5 Since non stop cutting is performed paper is fed and sto...

Страница 188: ... peripheral device such as an applicator must control the PAUSE signal generated from the expansion I O Head position Strip position 1 Place paper 2 Feeds back to the home position 3 Completes feeding to the top of form and stops Head position Strip position 1 Place paper The PAUSE signal generated from the expansion I O is turned ON 2 Remove the label The PAUSE signal generated from the expansion...

Страница 189: ...es according to types and sizes of the paper supply For details refer to the Supply Specification Model B SX4T B SX5T Parameter Rotary cutter not installed Rotary cutter installed 1 2 3 ips 3 ips 3 ips 3 4 5 5 ips 6 6 ips 7 6 ips 8 9 10 ips 8 ips A 5 With without ribbon Without ribbon The ribbon motor is not operated at feed With ribbon The ribbon motor is operated at feed With ribbon saving When ...

Страница 190: ...position refer to the section regarding the Issue Command 5 If no subsequent command is received from the PC for 1 second after the last label has been fed the printer automatically performs an approximately 13 7 mm forward feed when Automatic forward feed standby is set to ON in the system mode When the Feed Command is received during the forward feed standby the printer feeds the label in revers...

Страница 191: ...tandby is set to ON in the system mode When the Eject Command is received in the forward feed standby state the printer feeds the label in reverse to the original position and then ejects it For notes refer to the section regarding the Issue Command Examples The swing cutter is used Head position 1 Idling 2 Completes printing the 1st label A Cut position 3 Completes printing the 2nd label B 4 Comp...

Страница 192: ...C XS I 0001 0001C3001 LF NUL ESC IB LF NUL Head position 1 Idling 2 Completes printing the 1st label A Cut position 3 Completes printing the 2nd label B 4 Completes printing the 3rd label C 5 Feeds to the cut position by the Eject Command A A A A A B B B B C C C 6 Completes cutting labels 7 Since non stop cutting is performed paper is fed and stopped over the cut position 8 Feeds back to home posi...

Страница 193: ... power is turned off 3 The Forward Reverse Feed Command is ignored in the strip mode and the cut issue mode 4 The Forward Reverse Feed Command feeds the label without ribbon saving even if the ribbon saving issue is designated 5 The forward feed is performed at the speed designated by the Issue Command or Feed Command The reverse feed is performed at 3 ips This reverse feed speed can be changed fr...

Страница 194: ...UL Head position 2 Feeds one label Cut position 3 Feeds to the position at which a label can be cut manually 4 Cut manually 5 Standby 6 Feeds back to the home position 7 Prints three A labels 1 Idling 8 Feeds to the position at which labels can be cut manually 9 Cut manually 10 Standby 11 Feeds back to home position 12 Prints one B label 13 Feeds to the position at which a label can be cut manuall...

Страница 195: ...C file storage area specified by this command is 896 KB the TrueType font storage area the bit map writable character storage area and the BASIC file storage area are allocated as specified respectively In this case however there is no PC save area 6 If the sum of TrueType font storage area the bit map writable character storage area and the BASIC file storage area specified by this command exceed...

Страница 196: ... area specified by this command exceeds the size of 896 KB minus the BASIC file storage area size the TrueType font storage area is allocated as specified with the highest priority Then the remaining area is allocated to the bit map writable character storage area There is no PC save area 14 When 00 0 KB is specified for each of the TrueType font storage area and the bit map writable character sto...

Страница 197: ... this command is 3072 KB the TrueType font storage area the bit map writable character storage area and the BASIC file storage area are allocated as specified respectively In this case however there is no PC save area 6 If the sum of TrueType font storage area the bit map writable character storage area and the BASIC file storage area specified by this command exceeds 3072 KB the TrueType font sto...

Страница 198: ...rea specified by this command exceeds the size of 3072 KB minus the BASIC file storage area size the TrueType font storage area is allocated as specified with the highest priority Then the remaining area is allocated to the bit map writable character storage area There is no PC save area 14 When 00 0 KB is specified for each of the TrueType font storage area and the bit map writable character stor...

Страница 199: ...tialized before the PC interface command is saved or writable characters are stored 4 After the flash memory card is formatted the remaining memory is the PC save area 895 Kbytes and writable character storage area 3147 Kbytes The remaining memory is displayed on the LCD 5 When the flash memory card is used and the already stored data PC interface commands writable characters logos is stored again...

Страница 200: ... performed after the ATA Card Format Command is sent the image buffer is automatically cleared 3 When storing of writable characters logos or PC interface commands is not continued the printer automatically enters the online mode label issue operation after about 10 seconds In this case the image buffer is automatically cleared 4 Before the ATA card is formatted the Web printer function should be ...

Страница 201: ...n be deleted by designating the character code range and the capacity of flash memory is not wasted 2 The total number of characters for each range must not exceed 0x4000 16384 characters 3 Up to 2700 can be designated for the range 4 A character code which is not appropriate for the setting for this command cannot be stored 5 The first character code for each area to be set p should be sent in th...

Страница 202: ...1 to 40 41 16 16 dots 42 24 24 dots 43 32 32 dots 44 48 48 dots 51 2 byte code character b b Writable character code 20H to FFH Set in hex 40H to 7EH 80H to FCH When the writable character set is 41 to 44 2020H to FFFFH When the writable character is 51 ccc Left offset 000 to 719 in dots ddd Top offset 000 to 719 in dots eee Character width 001 to 720 in dots fff Character height 001 to 720 in dot...

Страница 203: ... When the writable character set is 51 to 55 ccc c Left offset B SX4T 000 to 831 in dots B SX5T 000 to 1535 in dots ddd d Top offset B SX4T and B SX5T 000 to 5460 in dots eee e Character width B SX4T 000 to 832 in dots B SX5T 000 to 1536 in dots fff f Character height B SX4T and B SX5T 000 to 5460 in dots ggg g Horizontal spacing proportional spacing B SX4T 000 to 832 in dots B SX5T 000 to 1536 in...

Страница 204: ...s of 2 bytes In this case up to 188 characters can be stored per character set 3 Only a 4 MB flash memory card can be used for storing a writable character 4 The configuration of the writable character file stored in the ATA card is as follows 1st byte No of dots for left offset 2nd byte from upper to lower 3rd byte No of dots for top offset 4th byte from upper to lower 5th byte No of dots for cha...

Страница 205: ...e writable character 0200 02002020 UDF W C file for character code 2020H Writable character 51 02002021 UDF W C file for character code 2021H 0201 Each W C file 02002022 UDF W C file for character code 2022H Writable character 52 0202 Each W C file 0200FFFD UDF W C file for character code FFFDH Writable character 53 0200FFFE UDF W C file for character code FFFEH 0203 Each W C file 0200FFFF UDF W C...

Страница 206: ...H 244 3CH 245 30H 246 30H 247 30H 248 30H Hex mode 1 00H 2 0FH 3 C0H 4 00H 5 FCH 6 7FH 120 00H 121 FFH 122 FCH 123 00H 124 00H Top offset 22 dots Char height 31 dots Reference point Char width 26 dots Horizontal spacing proportional spacing 30 dots Left offset Base line Reference point of next char 8 4 4 4 4 4 4 4 4 Char height 31 dots Char width 26 dots 8 8 8 ...

Страница 207: ...be stored is 00H to FFH 3 The minimum unit in the X direction is 8 dots Dots with no data are transmitted as data 0 4 The data count of writable characters to be stored must be as follows Data count of writable characters to be stored No of char width dots 7 8 No of char height dots The value in the brackets is rounded down to the nearest whole number Notes 1 With the same writable character set d...

Страница 208: ...1 64 High order digit 3 2 The data of writable characters to be stored is 30H to 3FH 3 The data count of writable characters to be stored should be 64 bytes Hex mode 1 The writable character data to be stored is separated into eight dot units and sent in the following order 1 32 2 The data of writable characters to be stored is 00H to FFH 3 The data count of writable characters to be stored should...

Страница 209: ...er 1 144 High order digit 3 2 The data of writable characters to be stored is 30H to 3FH 3 The data count of writable characters to be stored should be 144 bytes Hex mode 1 The writable character data to be stored is separated into eight dot units and sent in the following order 1 72 2 The data of writable characters to be stored is 00H to FFH 3 The data count of writable characters to be stored s...

Страница 210: ...the following order 1 256 High order digit 3 2 The data of writable characters to be stored is 30H to 3FH 3 The data count of writable characters to be stored should be 256 bytes Hex mode 1 The writable character data to be stored is separated into eight dot units and sent in the following order 1 128 2 The data of writable characters to be stored is 00H to FFH 3 The data count of writable charact...

Страница 211: ...n the following order 1 576 High order digit 3 2 The data of writable characters to be stored is 30H to 3FH 3 The data count of writable characters to be stored should be 576 bytes Hex mode 1 The writable character data to be stored is separated into eight dot units and sent in the following order 1 288 2 The data of writable characters to be stored is 00H to FFH 3 The data count of writable chara...

Страница 212: ...lash Memory Format Command ESC J1 before storing 4 If a flash memory card is used and a label issue operation is performed after sending the Bit Map Writable Character Command ESC XD the image buffer is cleared automatically 5 When the storing operation is not continued after storing the writable character and logos the printer automatically enters the online mode label issue operation after about...

Страница 213: ... 0001 01 0001 01 0001 01 0003 01 0003801 0007801 800 001 01 001 07 001 001 7 8001 0 0001 0000001 0000001 0000001 000000 0000 0000 0000 LF NUL Top offset 22 dots Char height 31 dots Reference point Char width 26 dots Horizontal spacing proportional spacing 30 dots Left offset 2 dots Base line Reference point of next char 30H 0 31H 1 32H 2 33H 3 34H 4 35H 5 36H 6 37H 7 38H 8 39H 9 3AH 3BH 3CH 3DH 3E...

Страница 214: ...n of the graphic width is contained in the graphic data dddd No of graphic height dots 4 or 5 digits in dots However when the graphic data 2 BMP file or 6 PCX file is selected this designation is ignored The information of the graphic width is contained in the graphic data When 3 TOPIX compression mode is selected for the type of graphic data Resolution of graphic data only two types 0150 150 DPI ...

Страница 215: ...e graphic data 4 or 5 is selected the graphic data is drawn by carrying out OR between the graphic data and the data in the image buffer Effective print width Print direction Printing top first Paper feed direction 0 Y X Print origin of coordinates Origin of coordinates 0 0 Graphic height dots Effective print length Graphic width dots Print direction Printing bottom first Effective print width Pap...

Страница 216: ...t be as follows Graphic data count No of graphic width dots 7 8 No of graphic height dots 2 The value in the brackets is rounded down to the nearest whole number Hex mode 1 The graphic data is separated into eight dot units and sent in the following order 1 66 2 The graphic data is 00H to FFH 3 The minimum unit in the X direction is 8 dots Dots with no data are transmitted as data 0 4 The graphic ...

Страница 217: ...rrent image data and the image data one line previous Only the changed bit is set to ON 1 The alignment of dots is MSB left dots and LSB right dots The graphic width for only the smaller value of either the designated value or the max buffer size 512 KB is drawn The minimum unit of the data drawing is 8 dots 1 byte If the graphic width is set to 3 dots it will be reset to 8 dots 1 byte L1 L1 Lengt...

Страница 218: ... m should not exceed 127 and 126 respectively If it exceeds the range it should be divided into blocks of repetition When the same contents as the data for 1 line appear repeatedly in the next line and after the number of lines in which the same contents appear is encoded in 2 bytes The first byte is fixed as 127 The second byte indicates N times that the same contents are repeated Its range is be...

Страница 219: ... data at high speed the data is directly developed in the image buffer without applying correction to each bit with respect to the designated X coordinate Consequently an error of up to 4 bits occurs Effective print area mm Model B SX4T B SX5T Cut Cut Swing Rotary cutter Swing Rotary cutter Issue mode Item Batch Strip cutter Head up operation not performed Head up operation performed Batch Strip c...

Страница 220: ...0033800031 00030 00030 00030600030 00030 00031 00033800 33003 0007 000 000 000 0007 0003 0000 LF NUL ESC XS I 0001 0002C3000 LF NUL 30H 0 38H 8 31H 1 39H 9 32H 2 3AH 33H 3 3BH 34H 4 3CH 35H 5 3DH 36H 6 3EH 37H 7 3FH Origin 0 0 Graphic width 19 dots Graphic height 22 dots 24 0 mm 10 0 mm ...

Страница 221: ... 40 01 80 80 20 20 6th line 7th line 8th line 9th line 80 80 20 80 80 80 20 80 80 80 20 20 80 80 40 01 10th line 11th line 12th line 13th line 80 80 60 02 40 80 80 A0 0F 80 80 80 C0 30 C3 80 80 80 40 14th line 15th line 16th line 17th line 80 80 80 80 80 80 40 10 00 80 80 C0 80 20 80 80 C0 40 C0 LF NUL 18th line 19th line 20th line 21st line 22nd line Origin 0 0 Graphic width 19 dots Graphic heigh...

Страница 222: ...e 1 Status response made Notes 1 After sending the Save Start Command ESC XO any command other than the following will be saved into flash memory without being analyzed Save Start Command ESC XO Save Terminate Command ESC XP Saved Data Call Command ESC XQ ESC XT Bit Map Writable Character Command ESC XD ESC XA Reset Command ESC WR Status Request Command ESC WS Flash Memory Format Command ESC J1 AT...

Страница 223: ...AVE is created and then the directory Specified file name PCS is created under the PCSAVE directory level 2 Up to about 1 MB can be saved per a save Notes 1 After sending the Save Start Command ESC XV any command other than the following will be saved into the ATA card without being analyzed Save Start Command ESC XO Save Terminate Command ESC XP Saved Data Call Command ESC XQ ESC XT Bit Map Writa...

Страница 224: ... commands Format ESC XP LF NUL Note If the storing operation is not continued after the PC interface command is stored the printer enters the online mode label issue operation after about 10 seconds In this case the image buffer will be cleared automatically Refer to Save Start Command ESC XO ESC XV ...

Страница 225: ...ve identification number is not found an error will result 2 However if no save identification number subject to auto call is found with the option for auto call at power on time selected the option for no auto call will be selected causing no error 3 If a command error is found in the PC interface command in auto call at power on time by the Saved Data Call Command a command error will result Aft...

Страница 226: ...wever if no save number subject to auto call is found with the option for auto call at power on time selected the option for no auto call will be selected causing no error 3 If a command error is found in the PC interface command in auto call at power on time by the Saved Data Call Command a command error will result After an error has occurred the power must be turned off The option for no auto c...

Страница 227: ...er or not the status is sent when an error occurs is determined according to the setting for the status response specified by the Issue Command If the check result is found to be normal when the check result status response is set a head broken dots check normal end status is sent and then the next command is processed If the check result is found to be abnormal the head broken dots error status i...

Страница 228: ...ollowing the Message Display Command Notes 1 16 characters are displayed When the display data is less than 16 characters the blank data is processed as spaces When the display data exceeds 16 characters the excess data is discarded 2 During a pause a halt due to an error or a head open state the Message Display Command is not processed even if it is received In this case the command is processed ...

Страница 229: ... T11C30 LF NUL ESC C LF NUL ESC PC001 0150 0410 1 1 A 00 B LF NUL ESC RC001 Sample LF NUL ESC XS I 0004 0011C3001 LF NUL ESC XJ Please set Tag LF NUL ESC D0600 0500 0570 LF NUL ESC T11C30 LF NUL ESC C LF NUL ESC XB01 0200 0100 3 1 03 03 08 08 03 0 0150 LF NUL ESC RB01 12345 LF NUL ESC XS I 0002 0011C3001 LF NUL S a m p l e 73 2 mm 41 0 mm 76 2 mm 15 0 mm 82 0 mm 57 0 mm 10 0 mm 60 0 mm 20 0 mm 50 ...

Страница 230: ...ocessing after this command is transmitted Notes 1 When the printer receives a command in the system mode only the Reset Command can be processed and any other commands cannot be processed 2 If a command error or communication error occurs when receiving the Reset Command the error message is displayed in the online mode However it is not displayed in the system mode 3 After the code of the Bit Ma...

Страница 231: ...status to the Nibble mode negotiation immediately after this command is received When ECP mode of Centronics is selected the printer returns a status to the reverse request immediately after this command is received 2 The status is returned only to the interface which sent this command 3 After the code of the Bit Map Writable Character Command ESC XD or Graphic Command ESC SG is received the Statu...

Страница 232: ...ces and socket communications However when SPP mode of Centronics is selected the printer returns a status to the Nibble mode negotiation immediately after this command is received When ECP mode of Centronics is selected the printer returns a status to the reverse request immediately after this command is received 2 The printer returns the status only for the interface which sent this command to t...

Страница 233: ...04H CR 0DH LF 0AH 2 This command is one of the command types that are processed as they are received Processing takes place starting from the ones received first Until the process of the command previously sent is completed the next command is not processed Therefore if the printer is not in the idle state when this command is sent the program version data may not be returned immediately Notes 1 T...

Страница 234: ...0 1 0 1 03H 04H 0DH 0AH If only one writable character is stored information of the writable character No is set to 1 Stored The storage information of a specified character code can be acquired by using the ATA Card Writable Character Information Acquire Command ESC WG The storage information of the writable character has a total of 55 bytes The writable character No is assigned from 01 to 44 and...

Страница 235: ...slot 2 This command is one of the command types that are processed as they are received Processing takes place starting from the ones received first Until the process of the command previously sent is completed this command is not processed Therefore if the printer is not in the idle state when this command is sent the information data may not be returned immediately Note 1 This command is effecti...

Страница 236: ...cter set Character code Storage ETX EOT CR LF 01H 02H 44H 3xH 3xH 3xH xxH xxH 0 1 03H 04H 0DH 0AH When the ATA card is not inserted in a specified slot 00H is returned for all information from Writable Character Set to Storage 5 bytes Example When the following information in the ATA card in Slot 1 is acquired Writable character set 44 writable character code 41H ESC WG 1 44 0x00 0x41 LF NUL 0x00 ...

Страница 237: ...ETX EOT CR LF 01H 02H 45H 30H 30H 30H 30H 30H 30H 30H 30H 30H 03H 04H 0DH 0AH Reserved A B and C Internal serial port 30H Not installed 31H RFID module H1 32H RFID module U1 33H RFID module H2 34H RFID module U2 Cutter 30H Not installed 31H Swing cutter 32H Rotary Cutter USB board 30H Not installed 31H Installed 100Base LAN board 30H Not installed 31H Installed PCMCIA Slot2 30H Not installed 31H A...

Страница 238: ...ress setting can also be made in the system mode The setting which was last made takes effect Example Sets the printer IP address to 157 69 9 78 ESC IP 2 157 069 009 078 LF NUL Function Enables or disables the socket communication and sets the communication port number to be used Format ESC IS a bbbbb LF NUL Term a 0 Socket communication is disabled 1 Socket communication is enabled bbbbb Port num...

Страница 239: ...mat ESC IS a bbbbb LF NUL Term a 0 Socket communication is disabled 1 Socket communication is enabled bbbbb Port number It must be set in 5 digits 00000 to 65535 Explanation These settings can also be made in the system mode The setting which was last made takes effect Example To enable the socket communication and set the port number to 8000 ESC IS 1 08000 LF NUL ...

Страница 240: ...es in Hex Explanation These settings can also be made in the system mode The setting which was last made takes effect FFH in the client ID is assumed as a terminator Therefore FFH must not be used in data If FFH is specified as the first byte of the DHCP client ID the printer assumes the DHCP client ID is not specified and uses the MAC address of the LAN board installed on the printer as the DHCP ...

Страница 241: ...to be passed through 001 to 999 bbb bbb Binary data to be passed through Explanation This command is used for making a serial communication with the RF ID module The number of bytes of data specified by this command is output to the internal serial interface CN14 RF ID without being processed Data received from the internal serial interface CN14 RF ID is output to the serial interface ...

Страница 242: ...by this command take effect immediately after this command is analyzed A restart of the printer is not required This command is saved into memory and is kept even if the power is turned OFF When a communication error occurs in the internal serial interface the ON LINE LED goes off and the ERROR LED goes ON INTERNAL COM ERR is displayed on the upper LCD and then the printer stops due to an error Ex...

Страница 243: ... 1 PC 852 2 PC 857 3 PC 8 4 PC 851 5 PC 855 6 PC 1250 7 PC 1251 8 PC 1252 9 PC 1253 A PC 1254 B PC 1257 C LATIN9 D Arabic E UTF 8 Supported by V4 4A or Xx x only b Font 0 selection 0 0 without slash 1 0 with slash c RS 232C communication speed 0 2400 bps 1 4800 bps 2 9600 bps 3 19200 bps 4 38400 bps 5 115200 bps d RS 232C data length 0 7 bits 1 8 bits e Stop bit length 0 1 bit 1 2 bits f RS 232C p...

Страница 244: ...AN 2 FRENCH 3 DUTCH 4 SPANISH 5 JAPANESE 6 ITALIAN i Forward feed standby after an issue 0 OFF Not performed 1 ON Performed j Fine adjustment direction for the stop position of the forward feed standby Increase the length of the forward feed Decrease the length of the forward feed kk Fine adjustment value for the stop position of the forward feed standby 00 to 50 in units of 0 1 mm in steps of 0 5...

Страница 245: ...ASCII code 3 v Automatic head broken dots check 0 OFF When the power is turned on the broken dots check is not automatically performed 1 ON When the power is turned on the broken dots check is automatically performed w Centronics ACK BUSY timing setting 0 TYPE1 1 TYPE2 x Web printer function setting 0 OFF Web printer function is disabled 1 ON Web printer function is enabled y Reset process when th...

Страница 246: ... specification setting Supported by V4 4A or Xx x only 0 STD 1 ORACLE Explanation 1 This command is not executed until the printer enters an idle state 2 With some exceptions the parameters set by this command take effect when the power is turned on or the printer is reset 1 The value can be set in units of 0 1 mm However the value which is actually set on the printer is in units of 0 5 mm When a ...

Страница 247: ...adjustment value 00 to 95 in units of 0 1 mm in steps of 0 5 mm 1 g Indicates the direction positive or negative in which the X coordinate fine adjustment is to be made Positive direction Negative direction hhh X coordinate fine adjustment value 000 to 995 in units of 0 1 mm in steps of 0 5 mm 1 i Indicates whether to increase or decrease the density in the thermal transfer print mode Increase dar...

Страница 248: ...stment value 00 to 40 in units of 0 1 V Explanation 1 This command is not executed until the printer enters an idle state 2 With some exceptions the parameters set by this command take effect when the power is turned on or the printer is reset 1 The value can be set in units of 0 1 mm However the value which is actually set on the printer is in units of 0 5 mm When a value from 0 0 mm to 0 4 mm is...

Страница 249: ...on 2 c RFID error tag detection Invalid from firmware V4 7 This is programmed in the printer system mode 0 Not detected 1 Detected ddd Max number of RFID issue retries 000 to 255 eee Max number of RFID read retries 000 to 255 ff RFID read retry time out 00 to 99 In units of 0 1 sec 0 0 sec to 9 9 sec ggg Max number of RFID write retries 000 to 255 hh RFID write retry time out 00 to 99 In units of ...

Страница 250: ...threshold for data write 00 to 15 pp AGC threshold lower limit for retry 00 to 15 q Hibiki tag multi word write setting 0 Disabled 1 Enabled Explanation 1 This command is not executed until the printer enters an idle state 2 With some exceptions the parameters set by this command take effect when the power is turned on or the printer is reset ...

Страница 251: ...ot executed until the printer enters an idle state Some values in the Parameter Set Command ESC Z2 1 and the Fine Adjustment Value Set Command ESC Z2 2 will take effect when the printer is initialized This command should be sent after the Parameter Set Command ESC Z2 1 or Fine Adjustment Value Set Command ESC Z2 2 is sent ...

Страница 252: ...xplanation 1 The printer automatically feeds paper forward or backward before writing data onto the RFID tag as specified in this command After that the printer returns the paper to the print start position for printing 2 Only the value of 30 or less or 30 or more becomes effective 3 When the head up function has been enabled it will be performed when the feed amount is set to 50 or less or 50 or ...

Страница 253: ...direction for the amount specified by 003 command This feed is to adjust the position of Label 2 so that it is positioned just above the antenna when Label 1 is at the print start position When the feed amount is set to 0 the printer does not feed the labels 2 Data is written onto the tag of Label 2 3 The printer feeds one label in the forward direction 4 Data is written onto the tag of Label 3 5 ...

Страница 254: ... 22 EPC Class 1 23 ISO18000 6B 24 EPC Class 1 Generation 2 Designates the type of RFID tag from which data is to be read When omitted the tag type set in system mode will be designated In accordance with the tag type designated by this setting the tag type set in system mode changes When 00 NONE is designated the backed up tag type will be set and the system mode setting will not be changed Id RFI...

Страница 255: ...r is intended for reading user data When reading tag ID this parameter is ignored 2 When the value exceeding the maximum number of bytes storable in a tag is designated for Number of bytes to be read a read error results 3 When the number of bytes to be read is omitted the user data and the ID bytes of the specified data bytes will be returned in accordance with the tag types as shown in the table...

Страница 256: ...area is read write protected In the case of HITACHI s Gen2 tag Hibiki 8 byte TID area is readable writable and 30 byte user area is readable writable 4 The format of information to be returned to the host is as follows SOH 01H STX 02H Start of the status block F 46H 30H Tag type 30H 30H30H Reading failed 31H31H I Code 31H32H Tag it 31H33H C220 31H34H ISO15693 31H35H C210 31H36H C240 31H37H C320 32...

Страница 257: ...H 42H 43H xxH xxH 44H 45H 46H 03H 04H 0DH 0AH When a reading succeeded When RFID read mode 2 Header F Tag type Tag ID 8 bytes Footer 01H 02H 46H 32H 33H 31H 32H 33H 34H 35H 36H 37H 38H 03H 04H 0DH 0AH When a reading succeeded When RFID read mode 3 Header F Tag type Tag ID User data 8 bytes 32 bytes Footer 01H 02H 46H 32H 32H 31H 32H xxH xxH xxH 44H 45H 46H 03H 04H 0DH 0AH Reading has failed Read d...

Страница 258: ...aulty 4 Usually the void pattern is automatically printed if writing data onto the RFID tag results in an error therefore this command does not need to be transmitted This command is intended to be used if writing data onto the RFID tag failed while the BASIC interpreter or the Pass Through Command is used and the RFID module is manually controlled to issue RFID labels 5 The paper printed by this ...

Страница 259: ...id This parameter is effective only when the tag type is ISO18000 6B When omitted the U Code V1 19 format is not used When 2 Reserved is selected operations are not guaranteed Pd Partition number Omissible 0 to 6 This parameter is effective only when U Code V1 19 or EPC format is designated When omitted 5 will be set Fe Filter number Omissible 0 to 7 This parameter is effective only when U Code V1...

Страница 260: ...Lock unlock setting Omissible Kill password Access password EPC code TID User data 00 Unlocked Unlocked Unlocked Unlocked Unlocked 01 Locked Unlocked Unlocked Unlocked Unlocked 02 Unlocked Locked Unlocked Unlocked Unlocked 03 Locked Locked Unlocked Unlocked Unlocked 04 Unlocked Unlocked Locked Unlocked Unlocked 05 Locked Unlocked Locked Unlocked Unlocked 06 Unlocked Locked Locked Unlocked Unlocked...

Страница 261: ...ent lock 50 Unlocked Permanent lock Unlocked Unlocked Permanent lock 51 Permanent lock Permanent lock Unlocked Unlocked Permanent lock 52 Unlocked Unlocked Permanent lock Unlocked Permanent lock 53 Permanent lock Unlocked Permanent lock Unlocked Permanent lock 54 Unlocked Permanent lock Permanent lock Unlocked Permanent lock 55 Permanent lock Permanent lock Permanent lock Unlocked Permanent lock 5...

Страница 262: ...designated this parameter is ignored When the RFID module type is the U1 the EPC area and user area are effective Hopppppppp User block password setting Effective only when the Hibiki tag is used for the B SX704 RFID U2 R Designates a password to lock certain user blocks Up to five user blocks can be specified continuously For example H4AABBCCDD H5BBCCDDEE H6CCDDEEFF o Designates a user area bank ...

Страница 263: ...on 0 Disabled 1 Enabled t Write lock designation Effective to Bank4 to Bank8 only 0 Disabled 1 Enabled u Write permanent lock designation Effective to Bank4 to Bank8 only 0 Disabled 1 Enabled v User block password read write lock designation Effective to Bank4 to Bank8 only 0 Disabled 1 Enabled w User block password read write permanent lock designation Effective to Bank4 to Bank8 only 0 Disabled ...

Страница 264: ...k7 User block 4 8 Bank8 User block 5 yyyyyyyy User block access password Fixed to 8 digit hexadecimal number 00000000 to FFFFFFFF ooo ooo Print data string Omissible Max 512 digits but the number of digits to be written is different depending on the tag types The result of a data write is returned in the following format SOH 01H STX 02H Indicates the start of the status block 30H 30H 36H33H Writin...

Страница 265: ... in the data of the Data Command or the Message Display Command 2 Manual Selection ESC LF NUL The control code of the command is ESC 1BH LF 0AH NUL 00H and the control code selection is not performed 3 Manual Selection The control code of the command is 7BH 7CH 7DH and the control code selection is not performed Data of 00H to 1FH is ignored and discarded in this mode However data of 00H to 1FH be...

Страница 266: ...ware error occurs the printer shows the error message and makes status response before stopping The Status Request Command and Reset Command only can be processed and other commands are not processed When the printer is restored by the RESTART key the printer enters the initial state which is obtained after the power is turned on 8 2 ERRORS IN ISSUING OR FEEDING 1 Paper Jam c When the relation bet...

Страница 267: ...lf finished label and then an error will result when the next label is at the home position d When an issue a feed or an ejection is attempted in a printer stop state while the transmissive sensor or the reflective sensor detects the label end state an error will result 4 Ribbon End Error processing differs depending on the setting of label end ribbon end process in the system mode When TYP1 is se...

Страница 268: ...hen the heat sink sensor detects an excessively high temperature 91 C or more an error will result 8 Ribbon Error c When the ribbon rewind motor sensor and ribbon back tension motor sensor do not perform detection if twice the prescribed time has passed an error will result An abnormal condition has occurred in the sensor for determining the torque for the ribbon motor A ribbon jam has occurred Th...

Страница 269: ...ed from an odd address Word data has been accessed from a place other than the boundary of the word data Long word data has been accessed from a place other than the boundary of the long word data 3 General invalid command exception An undefined command in a place other than the delay slot has been decoded 4 Slot invalid exception An undefined command in the delay slot has been decoded A command w...

Страница 270: ...de When an error has occurred the printer shows an error message sends a status response and then stops Only the Status Request Command and the Reset Command can be processed Other commands are not processed Restoration using the RESTART key is possible The printer resumes printing the label at which the error had occurred 2 RFID Error If a problem has occurred when the printer communicates with t...

Страница 271: ...waiting to be printed is transmitted This command is not stored in the receive buffer and executed immediately when it is received 3 Receive buffer free space status transmission function by status request Receive Buffer Free Space Status Request Command This function is available for the RS 232C USB Centronics interfaces and socket communications Upon request to send status by the Receive Buffer ...

Страница 272: ... status block 3XH Printer status Status 3XH Details are described above Status type 33H Indicates the status for the ECP mode Remaining 3XH Remaining issue count count 3XH Details are described above 3XH 3XH Length 3XH Total number of bytes of this status block 3XH Free space 3XH Free space of the receive buffer of receive buffer 3XH 00000 0 Kbyte to 99999 99999 Kbytes 3XH 3XH 3XH However the maxi...

Страница 273: ...n the thermal head 17 17 EXCESS HEAD TEMP The thermal head temperature has become excessively high 18 18 RIBBON ERROR An abnormal condition occurred in the sensor for determining the torque for the ribbon motor 21 21 REWIND FULL An overflow error has occurred in the rewinder 22 22 ON LINE Ribbon near end state Online 27 PAUSE Ribbon near end state In a pause state 28 ON LINE Ribbon near end state ...

Страница 274: ...tomatically retries according to the setting for the maximum number of RFID write retries When the void pattern printing is completed the printer sends this status 60 RFID WRITE ERROR When writing data onto the RFID tag continuously failed for the maximum number of RFID write retries the printer enters an error state and sends this status 61 61 RFID ERROR When the printer cannot communicate with t...

Страница 275: ...es Nibble mode negotiation immediately after ESC WB LF NUL is received 23 bytes ECP Automatic status transmission N A Reverse request immediately after ESC WS LF NUL is received 13 bytes Reverse request immediately after ESC WB LF NUL is received 23 bytes USB Automatic status transmission N A Reception of ESC WS LF NUL 13 bytes Reception of ESC WB LF NUL 23 bytes Socket communications Automatic st...

Страница 276: ...n out H L L H HEAD OPEN A feed or an issue was attempted with the head opened except the FEED key H L L L HEAD ERROR A broken dot error has occurred in the thermal head H L L L EXCESS HEAD TEMP The thermal head temperature has become excessively high H L L L RIBBON ERROR An abnormal condition occurred in the sensor for determining the torque for the ribbon motor H L L L REWIND FULL An overflow err...

Страница 277: ... which rewrites the data in the delay slot has been decoded H L L L RFID WRITE ERROR Writing data onto the RFID tag continuously failed for the maximum number of RFID write retries H L L L RFID ERROR The printer cannot communicate with the RFID module H L L L INPUT PASSWORD The printer is waiting for a password to be entered H L L L PASSWORD INVALID Password entered was not correct consecutively f...

Страница 278: ... Yes Yes 9 HEAD OPEN z A feed or an issue was attempted with the head opened except the FEED key Yes Yes 10 HEAD ERROR z A broken dot error has occurred in the thermal head Yes Yes 11 EXCESS HEAD TEMP z The thermal head temperature has become excessively high No Yes 12 RIBBON ERROR z An abnormal condition occurred in the sensor for determining the torque for the ribbon motor Yes Yes 13 REWIND FULL...

Страница 279: ...rror occurs a Command fetch from an odd address b Access to the word data from a place other than the boundary of the word data c Access to the long word data from a place other than the boundary of the long word data d Access to the area of 80000000H to FFFFFFFFH in the logic space in the user mode e Undefined command placed in other than the delay slot has been decoded f Undefined command in the...

Страница 280: ...ect consecutively for three times No No 29 RFID CONFIG ERR z z B SX704 RFID U2 US R only RFID module s destination code is not specified No No NOTE 1 When a command error is found in the command sent 16 bytes of the command code of the error command are displayed on the upper line of the LCD However LF and NUL are not displayed Example 1 ESC PC001 0A00 0300 2 2 A 00 B LF NUL Command error LCD disp...

Страница 281: ... memory capacity of writable character storage area for the flash memory card 0 to 3147 in K bytes Firmware V5 0 or greater MAIN4 R PC board or greater Remaining memory capacity of PC save area of the flash memory card 0 to 3072 in K bytes Remaining memory capacity of writable character storage area for the flash memory card 0 to 3072 in K bytes NOTE 4 If the ribbon near end detection setting is s...

Страница 282: ... FEHLER 12 ERREUR RUBAN 13 REWIND FULL 13 AUFWI VOLL 13 ERR REMB 14 SAVING 14 SP MOD 14 MEM LIB SAVING SP MOD MEM LIB 15 FLASH WRITE ERR 15 FLASH FEHLER 15 ERREUR MEM FLASH 16 FORMAT ERROR 16 FORMATFEHLER 16 ERREUR DE FORMAT 17 FLASH CARD FULL 17 FLASH ZU KLEIN 17 MEM INSUFFISANTE 18 POWER FAILURE 18 POWER FAILURE 18 POWER FAILURE 19 INITIALIZING 19 INITIALIZING 19 INITIALIZING 20 EEPROM ERROR 20 ...

Страница 283: ...UT 12 ERROR CINTA 12 13 OPROL VOL 13 REBOBI LLENO 13 14 MEM 14 SALVAR 14 MEM SALVAR 15 FLASH MEM FOUT 15 ERROR ESCRITURA 15 16 FORMAAT FOUT 16 ERROR DE FORMATO 16 17 GEHEUGEN VOL 17 MEMORIA INSUFICI 17 18 POWER FAILURE 18 POWER FAILURE 18 19 INITIALIZING 19 INITIALIZING 19 20 EEPROM ERROR 20 EEPROM ERROR 20 21 SYSTEM ERROR 21 SYSTEM ERROR 21 22 RFID WRITE ERROR 22 RFID WRITE ERROR 22 23 RFID ERROR...

Страница 284: ...ASTRO 9 TESTA APERTA 10 ERROR TESTA 11 TEMP TESTA ALTA 12 ERR NASTRO 13 RIAVV PIENO 14 SALVA SALVA 15 ERR SCRITT CARD 16 ERR FORMATTAZ 17 MEM CARD PIENA 18 POWER FAILURE 19 INITIALIZING 20 EEPROM ERROR 21 SYSTEM ERROR 22 RFID WRITE ERROR 23 RFID ERROR 24 INPUT PASSWORD 25 PASSWORD INVALID 26 RFID CONFIG ERR ...

Страница 285: ...Ã Î þ 8 8 H X h x ê ÿ Ï Þ 9 9 I Y i y ë Ö Ú A J Z j z è Ü Û B K k ï ø Ù C L l î ý D M m ì Ø Ý E N n Ä Ì g F O _ o Å ƒ 2 PC 8 0 1 2 3 4 5 6 7 8 9 A B C D E F 0 0 P p Ç É á C α 1 1 A Q a q ü æ í β 2 2 B R b r é Æ ó Γ 3 3 C S c s â ô ú π 4 4 D T d t ä ö ñ Σ 5 5 E U e u à ò Ñ σ 6 6 F V f v å û ª µ 7 7 G W g w ç ù º τ 8 8 H X h x ê ÿ Φ 9 9 I Y i y ë Ö Θ A J Z j z è Ü Ω B K k ï δ C L l î n D M m ì 2 E N...

Страница 286: ... æ í ª ß 2 2 B R b r é Æ ó Ê Ô 3 3 C S c s â ô ú Ë Ò 4 4 D T d t ä ö ñ È õ 5 5 E U e u à ò Ñ Á Õ 6 6 F V f v å û Â ã Í µ 7 7 G W g w ç ù À Ã Î 8 8 H X h x ê Ï 9 9 I Y i y ë Ö Ú A J Z j z è Ü Û B K k ï ø Ù C L l î ì D M m Ø ÿ E N n Ä Ì g F O _ o Å When Japanese message is selected in the system mode code 5CH indicates The Euro code B0H can be changed in the parameter setting in the system mode When...

Страница 287: ... 9 A B C D E F 0 0 P p C 1 1 A Q a q 2 2 B R b r 3 3 C S c s 4 4 D T d t 5 5 E U e u 6 6 F V f v 7 7 G W g w 8 8 H X h x 9 9 I Y i y A J Z j z B K k C L l D M m E N n g F O _ o When Japanese message is selected in the system mode code 5CH indicates The Euro code B0H can be changed in the parameter setting in the system mode When Japanese message is selected in the system mode code 5CH indicates Th...

Страница 288: ...3 4 5 6 7 8 9 A B C D E F 0 0 P p C 1 1 A Q a q 2 2 B R b r 3 3 C S c s 4 4 D T d t 5 5 E U e u µ 6 6 F V f v 7 7 G W g w 8 8 H X h x 9 9 I Y i y A J Z j z B K k C L l D M m E N n F O _ o When Japanese message is selected in the system mode code 5CH indicates The Euro code B0H can be changed in the parameter setting in the system mode When Japanese message is selected in the system mode code 5CH i...

Страница 289: ... F O _ o Ï ß ï ÿ 10 PC 1253 0 1 2 3 4 5 6 7 8 9 A B C D E F 0 0 P p C 1 1 A Q a q 2 2 B R b r 3 3 C S c s ƒ 4 4 D T d t 5 5 E U e u µ 6 6 F V f v 7 7 G W g w 8 8 H X h x 9 9 I Y i y A J Z j z ª B K k C L l D M m E N n F O _ o When Japanese message is selected in the system mode code 5CH indicates The Euro code B0H can be changed in the parameter setting in the system mode When Japanese message is ...

Страница 290: ... 1257 0 1 2 3 4 5 6 7 8 9 A B C D E F 0 0 P p C 1 1 A Q a q 2 2 B R b r 3 3 C S c s Ó ó 4 4 D T d t Ä ä 5 5 E U e u µ Å Õ å õ 6 6 F V f v Ö ö 7 7 G W g w 8 8 H X h x Ø ø 9 9 I Y i y É é A J Z j z B K k C L l Ü ü D M m E N n F O _ o Æ æ ß When Japanese message is selected in the system mode code 5CH indicates The Euro code B0H can be changed in the parameter setting in the system mode When Japanese...

Страница 291: ... î þ F O _ o Ï ß ï ÿ 14 Arabic 0 1 2 3 4 5 6 7 8 9 A B C D E F 0 0 P p C 1 1 A Q a q 2 2 B R b r 3 3 C S c s 4 4 D T d t 5 5 E U e u 6 6 F V f v 7 7 G W g w 8 8 H X h x 9 9 I Y i y A J Z j z B K k C L l D M m E N n F O _ o When Japanese message is selected in the system mode code 5CH indicates The Euro code B0H can be changed in the parameter setting in the system mode When Japanese message is sel...

Страница 292: ... 8 9 A B C D E F 0 0 P P C 1 1 A Q A Q 2 2 B R B R 3 3 C S C S 4 4 D T D T 5 5 E U E U 6 6 F V F V 7 7 G W G W 8 8 H X H X 9 9 I Y I Y A J Z J Z B K K C L L D M M E N N F O _ O When Japanese message is selected in the system mode code 5CH indicates The Euro code B0H can be changed in the parameter setting in the system mode When Japanese message is selected in the system mode code 5CH indicates Th...

Страница 293: ... 9 A B C D E F 0 0 P P C 1 1 A Q A Q 2 2 B R B R 3 3 C S C S 4 4 D T D T 5 5 E U E U 6 6 F V F V 7 7 G W G W 8 8 H X H X 9 9 I Y I Y A J Z J Z B K K C L L D M M E N N F O _ O When Japanese message is selected in the system mode code 5CH indicates The Euro code B0H can be changed in the parameter setting in the system mode When Japanese message is selected in the system mode code 5CH indicates The ...

Страница 294: ... 0 0 P P C 1 1 A Q A Q 2 2 B R B R 3 3 C S C S 4 4 D T D T 5 5 E U E U 6 6 F V F V 7 7 G W G W 8 8 H X H X 9 9 I Y I Y A J Z J Z B K K C L L D M M E N N F O _ O When Japanese message is selected in the system mode code 5CH indicates The Euro code B0H can be changed in the parameter setting in the system mode When Japanese message is selected in the system mode code 5CH indicates The Euro code B0H ...

Страница 295: ... R 3 3 C S C S 4 4 D T D T C 5 5 E U E U 6 6 F V F V 7 7 G W G W 8 8 H X H X 9 9 I Y I Y A J Z J Z B K K C L L D M M E N N F O _ O When Japanese message is selected in the system mode code 5CH indicates The Euro code B0H can be changed in the parameter setting in the system mode ...

Страница 296: ... Y A J Z B K C L D M E N F O d B SX5T 0 1 2 3 4 5 6 7 8 9 A B C D E F 0 0 P p 1 1 A Q a q 2 2 B R b r 3 3 C S c s 4 4 D T d t 5 5 E U e u 6 6 F V f v 7 7 G W g w 8 8 H X h x 9 9 I Y i y A J Z j z B K k C L l D M m E N n F O o When Japanese message is selected in the system mode code 5CH indicates When Japanese message is selected in the system mode code 5CH indicates ...

Страница 297: ... E N F O d B SX5T 0 1 2 3 4 5 6 7 8 9 A B C D E F 0 0 P p 1 1 A Q a q 2 2 B R b r 3 3 C S c s 4 4 D T d t 5 5 E U e u 6 6 F V f v 7 7 G W g w 8 8 H X h x 9 9 I Y i y A J Z j z B K k C L l D M m E N n F O o When Japanese message is selected in the system mode code 5CH indicates When Japanese message is selected in the system mode code 5CH indicates ...

Страница 298: ...M E N F O d B SX5T 0 1 2 3 4 5 6 7 8 9 A B C D E F 0 0 P p 1 1 A Q a q 2 2 B R b r 3 3 C S c s 4 4 D T d t 5 5 E U e u 6 6 F V f v 7 7 G W g w 8 8 H X h x 9 9 I Y i y A J Z j z B K k C L l D M m E N n F O o When Japanese message is selected in the system mode code 5CH indicates When Japanese message is selected in the system mode code 5CH indicates ...

Страница 299: ... Y A J Z B K C L D M E N F O d B SX5T 0 1 2 3 4 5 6 7 8 9 A B C D E F 0 0 P p 1 1 A Q a q 2 2 B R b r 3 3 C S c s 4 4 D T d t 5 5 E U e u 6 6 F V f v 7 7 G W g w 8 8 H X h x 9 9 I Y i y A J Z j z B K k C L l D M m E N n F O o When Japanese message is selected in the system mode code 5CH indicates When Japanese message is selected in the system mode code 5CH indicates ...

Страница 300: ... L D M E N F O d B SX5T 0 1 2 3 4 5 6 7 8 9 A B C D E F 0 0 P p 1 1 A Q a q 2 2 B R b r 3 3 C S c s 4 4 D T d t 5 5 E U e u 6 6 F V f v 7 7 G W g w 8 8 H X h x 9 9 I Y i y A J Z j z B K k C L l D M m E N n F O o When Japanese message is selected in the system mode code 5CH indicates When Japanese message is selected in the system mode code 5CH indicates ...

Страница 301: ... M E N F O d B SX5T 0 1 2 3 4 5 6 7 8 9 A B C D E F 0 0 P p 1 1 A Q a q 2 2 B R b r 3 3 C S c s 4 4 D T d t 5 5 E U e u 6 6 F V f v 7 7 G W g w 8 8 H X h x 9 9 I Y i y A J Z j z B K k C L l D M m E N n F O o When Japanese message is selected in the system mode code 5CH indicates When Japanese message is selected in the system mode code 5CH indicates ...

Страница 302: ...M E N F O d B SX5T 0 1 2 3 4 5 6 7 8 9 A B C D E F 0 0 P p 1 1 A Q a q 2 2 B R b r 3 3 C S c s 4 4 D T d t 5 5 E U e u 6 6 F V f v 7 7 G W g w 8 8 H X h x 9 9 I Y i y A J Z j z B K k C L l D M m E N n F O o When Japanese message is selected in the system mode code 5CH indicates When Japanese message is selected in the system mode code 5CH indicates ...

Страница 303: ...s 80h 89h are reduced to 80 d B SX5T 0 1 2 3 4 5 6 7 8 9 A B C D E F 0 0 P p 0 1 1 A Q a q 1 2 2 B R b r 2 3 3 C S c s 3 4 4 D T d t 4 5 5 E U e u 5 6 6 F V f v 6 7 7 G W g w 7 8 8 H X h x 8 9 9 I Y i y 9 A J Z j z B K k C L l D M m E N n F O _ o The size of the numerals of codes 80h 89h are reduced to 80 When Japanese message is selected in the system mode code 5CH indicates When Japanese message...

Страница 304: ...d to 80 d B SX5T 0 1 2 3 4 5 6 7 8 9 A B C D E F 0 0 P p 0 1 1 A Q a q 1 2 2 B R b r 2 3 3 C S c s 3 4 4 D T d t 4 5 5 E U e u 5 6 6 F V f v 6 7 7 G W g w 7 8 8 H X h x 8 9 9 I Y i y 9 A J Z j z B K k C L l D M m E N n F O _ o The size of the numerals of codes 80h 89h are reduced to 80 When Japanese message is selected in the system mode code 5CH indicates When Japanese message is selected in the ...

Страница 305: ...ed to 80 d B SX5T 0 1 2 3 4 5 6 7 8 9 A B C D E F 0 0 P p 0 1 1 A Q a q 1 2 2 B R b r 2 3 3 C S c s 3 4 4 D T d t 4 5 5 E U e u 5 6 6 F V f v 6 7 7 G W g w 7 8 8 H X h x 8 9 9 I Y i y 9 A J Z j z B K k C L l D M m E N n F O _ o The size of the numerals of codes 80h 89h are reduced to 80 When Japanese message is selected in the system mode code 5CH indicates When Japanese message is selected in the...

Страница 306: ...s 80h 89h are reduced to 80 d B SX5T 0 1 2 3 4 5 6 7 8 9 A B C D E F 0 0 P p 0 1 1 A Q a q 1 2 2 B R b r 2 3 3 C S c s 3 4 4 D T d t 4 5 5 E U e u 5 6 6 F V f v 6 7 7 G W g w 7 8 8 H X h x 8 9 9 I Y i y 9 A J Z j z B K k C L l D M m E N n F O _ o The size of the numerals of codes 80h 89h are reduced to 80 When Japanese message is selected in the system mode code 5CH indicates When Japanese message...

Страница 307: ...re reduced to 80 d B SX5T 0 1 2 3 4 5 6 7 8 9 A B C D E F 0 0 P p 0 1 1 A Q a q 1 2 2 B R b r 2 3 3 C S c s 3 4 4 D T d t 4 5 5 E U e u 5 6 6 F V f v 6 7 7 G W g w 7 8 8 H X h x 8 9 9 I Y i y 9 A J Z j z B K k C L l D M m E N n F O _ o The size of the numerals of codes 80h 89h are reduced to 80 When Japanese message is selected in the system mode code 5CH indicates When Japanese message is selecte...

Страница 308: ...ced to 80 d B SX5T 0 1 2 3 4 5 6 7 8 9 A B C D E F 0 0 P p 0 1 1 A Q a q 1 2 2 B R b r 2 3 3 C S c s 3 4 4 D T d t 4 5 5 E U e u 5 6 6 F V f v 6 7 7 G W g w 7 8 8 H X h x 8 9 9 I Y i y 9 A J Z j z B K k C L l D M m E N n F O _ o The size of the numerals of codes 80h 89h are reduced to 80 When Japanese message is selected in the system mode code 5CH indicates When Japanese message is selected in th...

Страница 309: ... C L l î D M m ì Ø E N n Ä g F O _ o Å ƒ 2 PC 8 0 1 2 3 4 5 6 7 8 9 A B C D E F 0 0 P p Ç É á C α 1 1 A Q a q ü æ í C β 2 2 B R b r é Æ ó Γ 3 3 C S c s â ô ú π 4 4 D T d t ä ö ñ Σ 5 5 E U e u à ò Ñ σ 6 6 F V f v å û ª µ 7 7 G W g w ç ù º τ 8 8 H X h x ê ÿ Φ 9 9 I Y i y ë Ö Θ A J Z j z è Ü Ω B K k ï δ C L l î n D M m ì 2 E N n Ä Pt ε g F O _ o Å The Euro code B0H can be changed in the parameter set...

Страница 310: ..._ o 4 PC 857 0 1 2 3 4 5 6 7 8 9 A B C D E F 0 0 P p Ç É á C º 1 1 A Q a q ü æ í C ª ß 2 2 B R b r é Æ ó 3 3 C S c s â ô ú 4 4 D T d t ä ö ñ õ 5 5 E U e u à ò Ñ 6 6 F V f v å û ã µ 7 7 G W g w ç ù 8 8 H X h x ê 9 9 I Y i y ë Ö A J Z j z è Ü B K k ï ø C L l î ì D M m Ø ÿ 2 E N n Ä g F O _ o Å The Euro code B0H can be changed in the parameter setting in the system mode The Euro code B0H can be chang...

Страница 311: ...z è Ü B K k Ï C L l î D M m E N n Ä g F O _ o 6 PC 855 0 1 2 3 4 5 6 7 8 9 A B C D E F 0 0 P p C 1 1 A Q a q C 2 2 B R b r 3 3 C S c s 4 4 D T d t 5 5 E U e u 6 6 F V f v 7 7 G W g w 8 8 H X h x 9 9 I Y i y A J Z j z B K k C L l D M m E N n g F O _ o The Euro code B0H can be changed in the parameter setting in the system mode The Euro code B0H can be changed in the parameter setting in the system ...

Страница 312: ...ú B K k ë C L l Ü ü D M m Í E N n Î F O _ o ß 8 PC 1251 0 1 2 3 4 5 6 7 8 9 A B C D E F 0 0 P p C 1 1 A Q a q C 2 2 B R b r 3 3 C S c s 4 4 D T d t 5 5 E U e u µ 6 6 F V f v 7 7 G W g w 8 8 H X h x 9 9 I Y i y A J Z j z B K k C L l D M m E N n F O _ o The Euro code B0H can be changed in the parameter setting in the system mode The Euro code B0H can be changed in the parameter setting in the system...

Страница 313: ... j z ª ê ú B K k ë û C L l Ü ì ü D M m Í E N n î F O _ o ß ï ÿ 10 PC 1253 0 1 2 3 4 5 6 7 8 9 A B C D E F 0 0 P p C 1 1 A Q a q C 2 2 B R b r 3 3 C S c s ƒ 4 4 D T d t 5 5 E U e u µ 6 6 F V f v 7 7 G W g w 8 8 H X h x 9 9 I Y i y A J Z j z ª B K k C L l D M m E N n F O _ o The Euro code B0H can be changed in the parameter setting in the system mode The Euro code B0H can be changed in the parameter...

Страница 314: ... K k ë û C L l Ü ì ü D M m Í E N n î F O _ o ß Ï ÿ 12 PC 1257 0 1 2 3 4 5 6 7 8 9 A B C D E F 0 0 P p C 1 1 A Q a q C 2 2 B R b r 3 3 C S c s ó 4 4 D T d t Ä ä 5 5 E U e u µ Å å õ 6 6 F V f v Ö ö 7 7 G W g w 8 8 H X h x Ø ø 9 9 I Y i y É é A J Z j z B K k C L l Ü ü D M m E N n F O _ o Æ æ ß The Euro code B0H can be changed in the parameter setting in the system mode The Euro code B0H can be change...

Страница 315: ...J Z j z ª º ê ú B K k ë û C L l Ü ì ü D M m Í E N n î F O _ o ß Ï ÿ 14 Arabic 0 1 2 3 4 5 6 7 8 9 A B C D E F 0 0 P p C 1 1 A Q a q C 2 2 B R b r 3 3 C S c s 4 4 D T d t 5 5 E U e u 6 6 F V f v 7 7 G W g w 8 8 H X h x 9 9 I Y i y A J Z j z B K k C L l D M m E N n F O _ o The Euro code B0H can be changed in the parameter setting in the system mode The Euro code B0H can be changed in the parameter s...

Страница 316: ... 312 12 6 PRICE FONT 1 2 3 Outline font type E F G 1 All types of character codes 0 1 2 3 4 5 6 7 8 9 A B C D E F 0 0 1 1 2 2 3 3 4 4 5 5 6 6 7 7 8 8 9 9 A B C D E F ...

Страница 317: ... Ä Ì g F O _ o Å ƒ 2 PC 8 0 1 2 3 4 5 6 7 8 9 A B C D E F 0 0 P p Ç É á C 1 1 A Q a q ü æ í 2 2 B R b r é Æ ó 3 3 C S c s â ô ú 4 4 D T d t ä ö ñ 5 5 E U e u à ò Ñ 6 6 F V f v å û ª µ 7 7 G W g w ç ù º 8 8 H X h x ê ÿ 9 9 I Y i y ë Ö A J Z j z è Ü B K k ï C L l î D M m ì E N ˆ n Ä g F O _ o Å ƒ When Japanese message is selected in the system mode code 5CH indicates The Euro code B0H can be changed...

Страница 318: ...857 0 1 2 3 4 5 6 7 8 9 A B C D E F 0 0 P p Ç É á C º Ó 1 1 A Q a q ü æ í ª ß 2 2 B R b r é Æ ó Ê Ô 3 3 C S c s â ô ú Ë Ò 4 4 D T d t ä ö ñ È õ 5 5 E U e u à ò Ñ Á Õ 6 6 F V f v å û G Â ã Í µ 7 7 G W g w ç ù g À Ã Î 8 8 H X h x ê I Ï 9 9 I Y i y ë Ö Ú A J Z j z è Ü Û B K k ï ø Ù C L l î ì D M m Ø ÿ E N ˆ n Ä S Ì g F O _ o Å s When Japanese message is selected in the system mode code 5CH indicates ...

Страница 319: ... 9 A B C D E F 0 0 P p C 1 1 A Q a q 2 2 B R b r 3 3 C S c s 4 4 D T d t 5 5 E U e u 6 6 F V f v 7 7 G W g w 8 8 H X h x 9 9 I Y i y A J Z j z B K k C L l D M m E N ˆ n g F O _ o When Japanese message is selected in the system mode code 5CH indicates The Euro code B0H can be changed in the parameter setting in the system mode When Japanese message is selected in the system mode code 5CH indicates ...

Страница 320: ... M m Í Ý í ý E N n Z z I Î T î t F O _ o Z Z z z D ß 8 PC 1251 0 1 2 3 4 5 6 7 8 9 A B C D E F 0 0 P p C 1 1 A Q a q 2 2 B R b r 3 3 C S c s 4 4 D T d t 5 5 E U e u µ 6 6 F V f v 7 7 G W g w 8 8 H X h x 9 9 I Y i y A J Z j z B K k C L l D M m E N n F O _ o When Japanese message is selected in the system mode code 5CH indicates The Euro code B0H can be changed in the parameter setting in the system...

Страница 321: ...Î î F O _ o Ï ß ï ÿ 10 PC 1253 0 1 2 3 4 5 6 7 8 9 A B C D E F 0 0 P p C 1 1 A Q a q 2 2 B R b r 3 3 C S c s ƒ 4 4 D T d t 5 5 E U e u µ 6 6 F V f v 7 7 G W g w 8 8 H X h x 9 9 I Y i y A J Z j z ª B K k C L l D M m E N n F O _ o When Japanese message is selected in the system mode code 5CH indicates The Euro code B0H can be changed in the parameter setting in the system mode When Japanese message ...

Страница 322: ...3 4 5 6 7 8 9 A B C D E F 0 0 P p C A S a s 1 1 A Q a q N n 2 2 B R b r 3 3 C S c s C Ó c ó 4 4 D T d t Ä ä 5 5 E U e u µ Å Õ å õ 6 6 F V f v E Ö e ö 7 7 G W g w 8 8 H X h x Ø ø C c 9 9 I Y i y É L é l A J Z j z Z S z s B K k C L l Ü ü D M m Z z E N n Z z F O _ o Æ æ ß When Japanese message is selected in the system mode code 5CH indicates The Euro code B0H can be changed in the parameter setting ...

Страница 323: ...n Î î ÿ F O _ o Ï ß ï 14 Arabic 0 1 2 3 4 5 6 7 8 9 A B C D E F 0 0 P p C 1 1 A Q a q 2 2 B R b r 3 3 C S c s 4 4 D T d t 5 5 E U e u 6 6 F V f v 7 7 G W g w 8 8 H X h x 9 9 I Y i y A J Z j z B K k C L l D M m E N n F O _ o When Japanese message is selected in the system mode code 5CH indicates The Euro code B0H can be changed in the parameter setting in the system mode When Japanese message is se...

Страница 324: ...SE KANJI 1 GB18030 Chinese Kanji 0 1 2 3 4 5 6 7 8 9 A B C D E F 0 0 P p 1 1 A Q a q 2 2 B R b r 3 3 C S c s 4 4 D T d t 5 5 E U e u 6 6 F V f v 7 7 G W g w 8 8 H X h x 9 9 I Y i y A J Z j z B K k C L l D M m E N ˆ n F O _ o ...

Страница 325: ... 321 2 GB18030 code tables TBD ...

Страница 326: ... 322 TBD ...

Страница 327: ... 323 TBD ...

Страница 328: ... 324 TBD ...

Страница 329: ... 325 12 9 TrueType FONT 1 PC 850 2 PC 8 ...

Страница 330: ... 326 3 PC 852 4 PC 857 ...

Страница 331: ... 327 5 PC 851 6 PC 855 ...

Страница 332: ... 328 7 PC 1250 8 PC 1251 ...

Страница 333: ... 329 9 PC 1252 10 PC 1253 ...

Страница 334: ... 330 11 PC 1254 12 PC 1257 ...

Страница 335: ...Ñ á ñ 2 2 B R b r Â Ò â ò 3 3 C S c s Ã Ó ã ó 4 4 D T d t C Z Ä Ô ä ô 5 5 E U e u µ Å Õ å õ 6 6 F V f v S Æ Ö æ ö 7 7 G W g w Ç ç 8 8 H X h x s z È Ø è ø 9 9 I Y i y É Ù é ù A J Z j z ª º Ê Ú ê ú B K k Ë Û ë û C L l Œ Ì Ü ì ü D M m œ Í Ý í ý E N n Ÿ Î Þ î þ F O _ o Ï ß ï ÿ 14 Arabic ...

Страница 336: ... V 7 7 7 7 G W 8 8 8 8 H X 9 9 9 9 I Y A A J Z B B K C C L D D M E E N F F O 3 CODE39 Full ASCII Transfer code Drawing code 2 3 4 5 6 7 2 3 4 5 6 7 0 SP 0 P p 0 SP 0 V P W P 1 1 A Q a q 1 A 1 A Q A Q 2 2 B R b r 2 B 2 B R B R 3 3 C S c s 3 C 3 C S C S 4 4 D T d t 4 D 4 D T D T 5 5 E U e u 5 E 5 E U E U 6 6 F V f v 6 F 6 F V F V 7 7 G W g w 7 G 7 G W G W 8 8 H X h x 8 H 8 H X H X 9 9 I Y i y 9 I 9 ...

Страница 337: ...P p 0 SP 0 V P W P 1 1 A Q a q 1 A 1 A Q A Q 2 2 B R b r 2 B 2 B R B R 3 3 C S c s 3 C 3 C S C S 4 4 D T d t 4 D 4 D T D T 5 5 E U e u 5 E 5 E U E U 6 6 F V f v 6 F 6 F V F V 7 7 G W g w 7 G 7 G W G W 8 8 H X h x 8 H 8 H X H X 9 9 I Y i y 9 I 9 I Y I Y A J Z j z A J Z J Z J Z B K k B F K K K P C L l C L G L L L Q D M m D H M M M R E N n E I N N N S F O _ o F J O O O T ...

Страница 338: ... 9 I Y i y A LF SUB J Z j z B VT ESC K k C FF FS L l D CR GS M m E SO RS N n F SI US O _ o c How to transmit control code data NUL 00H 3EH 40H SOH 01H A 3EH 41H STX 02H B 3EH 42H to GS 1DH 3EH 5DH RS 1EH 3EH 5EH US 1FH _ 3EH 5FH d How to transmit special codes Value 30 Character 0 95 1 96 2 97 3 98 4 99 5 100 6 101 7 102 8 e Designation of start code START CODE A 7 START CODE B 6 START CODE C 5 Dr...

Страница 339: ...50 R R 50 86 SYN v 86 15 15 51 S S 51 87 ETB w 87 16 0 0 16 52 T T 52 88 CAN x 88 17 1 1 17 53 U U 53 89 EM y 89 18 2 2 18 54 V V 54 90 SUB z 90 19 3 3 19 55 W W 55 91 ESC 91 20 4 4 20 56 X X 56 92 FS 92 21 5 5 21 57 Y Y 57 93 GS 93 22 6 6 22 58 Z Z 58 94 RS 94 23 7 7 23 59 59 95 US DEL 95 24 8 8 24 60 60 96 FNC3 FNC3 96 25 9 9 25 61 61 97 FNC2 FNC2 97 26 26 62 62 98 SHIFT SHIFT 98 27 27 63 _ _ 63...

Страница 340: ...OH DC1 1 A Q a q 2 STX DC2 2 B R b r 3 ETX DC3 3 C S c s 4 EOT DC4 4 D T d t 5 ENQ NAK 5 E U e u 6 ACK SYN 6 F V f v 7 BEL ETB 7 G W g w 8 BS CAN 8 H X h x 9 HT EM 9 I Y i y A LF SUB J Z j z B VT ESC K k C FF FS L l D CR GS M m E SO RS N n F SI US O _ o c How to send control code data NUL 00H 3EH 40H SOH 01H A 3EH 41H STX 02H B 3EH 42H to GS 1DH 3EH 5DH RS 1EH 3EH 5EH US 1FH _ 3EH 5FH d How to sen...

Страница 341: ...p 1 SOH DC1 1 A Q a q 2 STX DC2 2 B R b r 3 ETX DC3 3 C S c s 4 EOT DC4 4 D T d t 5 ENQ NAK 5 E U e u 6 ACK SYN 6 F V f v 7 BEL ETB 7 G W g w 8 BS CAN 8 H X h x 9 HT EM 9 I Y i y A LF SUB J Z j z B VT ESC K k C FF FS L l D CR GS M m E SO RS N n F SI US O _ o c How to send control code data NUL 00H 3EH 40H SOH 01H A 3EH 41H STX 02H B 3EH 42H to GS 1DH 3EH 5DH RS 1EH 3EH 5EH US 1FH _ 3EH 5FH d How t...

Страница 342: ... b r 3 ETX DC3 3 C S c s 4 EOT DC4 4 D T d t 5 ENQ NAK 5 E U e u 6 ACK SYN 6 F V f v 7 BEL ETB 7 G W g w 8 BS CAN 8 H X h x 9 HT EM 9 I Y i y A LF SUB J Z j z B VT ESC K k C FF FS L l D CR GS M m E SO RS N n F SI US O _ o c How to send control code data NUL 00H 3EH 40H SOH 01H A 3EH 41H STX 02H B 3EH 42H to GS 1DH 3EH 5DH RS 1EH 3EH 5EH US 1FH _ 3EH 5FH d How to send a special code 3EH 0 3EH 30H e...

Страница 343: ...de Details N Numerals 0 to 9 A Alphanumerics symbols A to Z 0 to 9 space B Binary 8 bit 00H to FFH K Kanji Shift JIS JIS hexadecimal If mixed mode is selected up to 200 modes can be selected in a QR code When the automatic mode is selected in the Format Command for a QR code Data to be printed Transfer code for QR code 0 1 2 3 4 5 6 7 8 9 A B C D E F 0 NUL DLE SP 0 P p 1 SOH DC1 1 A Q a q 2 STX DC...

Страница 344: ... A B C 1 2 3 Data to be printed Designation of mode d Binary mode 01H 03H 05H B 0 0 0 6 A C E Data to be printed No of data strings Designation of mode e Mixed mode Numeric mode 123456 Kanji mode Kanji data Binary mode a i u e o Alphanumeric and symbol mode ABC N 1 2 3 4 5 6 K Kanji data B 0 0 1 0 a i u e o A A B C Designation of mode f Automatic mode When the same data as e above is designated in...

Страница 345: ...C KIX CODE 2 3 4 5 6 7 2 3 4 5 6 7 0 0 P 0 0 P p 1 1 A Q 1 1 A Q a q 2 2 B R 2 2 B R b r 3 3 C S 3 3 C S c s 4 4 D T 4 4 D T d t 5 5 E U 5 5 E U e u 6 6 F V 6 6 F V f v 7 7 G W 7 7 G W g w 8 8 H X 8 8 H X h x 9 9 I Y 9 9 I Y i y A J Z A J Z j z B K B K k C L C L l D M D M m E N E N n F O F O o or can be designated only as a start stop code These should not be entered in data If these are entered b...

Страница 346: ...011 EC EC EC EC EC 28 011100 FS 28 FS 28 FS 28 FS 28 Pad 29 011101 GS 29 GS 29 GS 29 GS 29 Pad 30 011110 RS 30 RS 30 RS 30 RS 30 ESC 27 31 011111 NS NS NS NS NS 32 100000 Space 32 123 Û 219 û 251 FS 28 33 100001 Pad Pad Ü 220 ü 252 GS 29 34 100010 34 125 Ý 221 ý 253 RS 30 35 100011 35 126 Þ 222 þ 254 US 31 36 100100 36 DEL 127 ß 223 ÿ 255 C159 159 37 100101 37 59 ª 170 161 NBSP 160 38 100110 38 60...

Страница 347: ...pecial specification in the system mode Transfer code for MaxiCode 0 1 2 3 4 5 6 7 8 9 A B C D E F 0 NUL DLE SP 0 P p 1 SOH DC1 1 A Q a q 2 STX DC2 2 B R b r 3 ETX DC3 3 C S c s 4 EOT DC4 4 D T d t 5 ENQ NAK 5 E U e u 6 ACK SYN 6 F V f v 7 BEL ETB 7 G W g w 8 BS CAN 8 H X h x 9 HT EM 9 I Y i y A LF Note1 SUB J Z j z B VT ESC K k C FF FS L l D CR GS M m E SO RS N n F SI US O _ o DEL Note2 The all c...

Страница 348: ... W g w 8 BS CAN 8 H X h x 9 HT EM 9 I Y i y A LF SUB J Z j z B VT ESC K k C FF FS L l D CR GS M m E SO RS N n F SI US O _ o c How to send control code data NUL 00H 3EH 40H SOH 01H A 3EH 41H STX 02H B 3EH 42H to GS 1DH 3EH 5DH RS 1EH 3EH 5EH US 1FH _ 3EH 5FH d How to send a special code 3EH 0 3EH 30H e How to send a Kanji code Shift JIS JIS hexadecimal For details refer to the section for the Bar C...

Страница 349: ...d between the stacked bar codes The height varies depending on the versions of bar code and fixed Height of the separator for the stacked bar code Version of bar code Height of separator GS1 DataBar Stacked Module width GS1 DataBar Stacked Omnidirectional Module width x 3 layers GS1 DataBar Expanded Stacked Module width x 3 layers Example d Recommended bar code height Bar code version Height 1 GS1...

Страница 350: ...aBar Expanded 74 digits Numeral only 1 41 digits Alphabet only GS1 DataBar Expanded Stacked 74 digits Numeral only 1 41 digits Alphabet only 1 Max 74 digits 41 digits including AI and FID In the following case the print results vary in spite of the same number of digits Non printable 1A2B3C4D5E6F7G8H9I0J1K2L3M4N5O6P7Q8R9S0T1U2V3W Printable ABCDEFGHIJKLMNOPQRSTUVW12345678901234567890123 g Check dig...

Страница 351: ... e u 6 ACK SYN 6 F V f v 7 BEL ETB 7 G W g w 8 BS CAN 8 H X h x 9 HT EM 9 I Y i y A LF SUB J Z j z B VT ESC K k C FF FS L l D CR GS M m E SO RS N n F SI US O _ o DEL All codes can be used 00H to FFH c How to send control code data NUL 00H 3EH 40H SOH 01H A 3EH 41H STX 02H B 3EH 42H to GS 1DH 3EH 5DH RS 1EH 3EH 5EH US 1FH _ 3EH 5FH d How to send a special code 3EH 0 3EH 30H ...

Страница 352: ...ulus 10 C D Drawing Data Other than 8 digits Not to be drawn 2 Modulus 10 check No of Input Digits 8 digits Input Data To be checked as modulus 10 C D Drawing Data Other than 8 digits Not to be drawn 3 Auto affix of modulus 10 No of Input Digits Input Data 7 digits Drawing Data Affix a modulus 10 C D Other than 7 digits Not to be drawn D8 D7 D6 D5 D4 D3 D2 D1 D8 D7 D6 D5 D4 D3 D2 D1 D8 D7 D6 D5 D4...

Страница 353: ... Digits Input Data 11 digits Drawing Data Affix a modulus 10 C D Affix price C D 4 digits Other than 11 digits Not to be drawn 5 Auto affix of modulus 10 Price C D 5 digits No of Input Digits Input Data 11 digits Drawing Data Affix a modulus 10 C D Affix price C D 5 digits Other than 11 digits Not to be drawn D8 D7 D6 D5 D4 D3 D2 D1 D13 D12 D11 D10 D9 D8 D7 D6 D5 D4 D3 D2 D13 D12 D11 D10 D9 D8 D7 ...

Страница 354: ... of Input Digits Input Data 10 digits Drawing Data Affix a modulus 10 C D Affix price C D 4 digits Other than 10 digits Not to be drawn 5 Auto affix of modulus 10 Price C D 5 digits No of Input Digits Input Data 10 digits Drawing Data Affix a modulus 10 C D Affix price C D 5 digits Other than 10 digits Not to be drawn D8 D7 D6 D5 D4 D3 D2 D1 D12 D11 D10 D9 D8 D7 D6 D5 D4 D3 D2 D1 D12 D11 D10 D9 D8...

Страница 355: ...s 7 digits Input Data To be checked as modulus 10 C D Drawing Data Other than 7 digits Not to be drawn 3 Auto affix of modulus 10 No of Input Digits 6 digits Input Data Calculate and reflect modulus 10 in the bar code Drawing Data Other than 6 digits Not to be drawn D7 D6 D5 D4 D3 D2 D1 D7 D6 D5 D4 D3 D2 D1 0 D7 D6 D5 D4 D3 D2 D1 D7 D6 D5 D4 D3 D2 D1 0 D6 D5 D4 D3 D2 D1 C D D6 D5 D4 D3 D2 D1 0 ...

Страница 356: ...10 digits Input Data To be checked as modulus 10 C D Drawing Data Other than 10 digits Not to be drawn 3 Auto affix of modulus 10 No of Input Digits Input Data 9 digits Drawing Data Affix a modulus 10 C D Other than 9 digits Not to be drawn D8 D7 D6 D5 D4 D3 D2 D1 D10 D9 D8 D7 D6 D5 D4 D3 D2 D1 D10 D9 D8 D7 D6 D5 D4 D3 D2 D1 D10 D9 D8 D7 D6 D5 D4 D3 D2 D1 D10 D9 D8 D7 D6 D5 D4 D3 D2 D1 D9 C D D8 D...

Страница 357: ... modulus 10 C D Drawing Data Other than 13 digits Not to be drawn 3 Auto affix of modulus 10 No of Input Digits Input Data 12 digits Drawing Data Affix a modulus 10 C D Other than 12 digits Not to be drawn D8 D7 D6 D5 D4 D3 D2 D1 D10 D9 D11 D13 D12 D8 D7 D6 D5 D4 D3 D2 D1 D10 D9 D13 D12 D11 D8 D7 D6 D5 D4 D3 D2 D1 D10 D9 D11 D13 D12 D8 D7 D6 D5 D4 D3 D2 D1 D10 D9 D13 D12 D11 D8 D7 D6 D5 D4 D3 D2 D...

Страница 358: ...awing Data Affix a modulus 10 C D Affix price C D 4 digits Other than 13 digits Not to be drawn 5 Auto affix of modulus 10 Price C D 5 digits No of Input Digits Input Data 13 digits Drawing Data Affix a modulus 10 C D Affix price C D 5 digits Other than 13 digits Not to be drawn D8 P CD D7 D6 D5 D4 D3 D2 C D D11 D10 D9 D8 D7 D6 D5 D4 D3 D2 D1 D11 D10 D9 D13 D12 D13 D12 D8 D7 D6 D5 D4 D3 D2 D1 D13 ...

Страница 359: ...ther than 16 digits Not to be drawn 5 Auto affix of modulus 10 Price C D 5 digits No of Input Digits Input Data 16 digits Drawing Data Affix a modulus 10 C D Affix price C D 5 digits Other than 16 digits Not to be drawn D8 D7 D6 D5 D4 D3 D2 D1 D13 D12 D11 D10 D9 D8 D7 D6 D5 D4 D3 D2 C D D12 D11 D10 D9 D14 D14 D13 D16 D15 D17 D16 D15 D17 D8 D7 D6 D5 D4 D3 D2 D1 D13 D12 D11 D10 D9 D15 D14 D16 D18 D1...

Страница 360: ...ts Drawing Data Affix a modulus 10 C D Affix price C D 4 digits Other than 12 digits Not to be drawn 5 Auto affix of modulus 10 Price C D 5 digits No of Input Digits Input Data 12 digits Drawing Data Affix a modulus 10 C D Affix price C D 5 digits Other than 12 digits Not to be drawn D8 D7 D6 D5 D4 D3 D2 D1 D11 D10 D9 D13 D12 C D D8 D7 D6 D5 D4 D3 D2 D1 D11 D10 D9 D13 D12 D8 D7 D6 D5 D4 D3 D2 D1 D...

Страница 361: ...its Other than 15 digits Not to be drawn 5 Auto affix of modulus 10 Price C D 5 digits No of Input Digits Input Data 15 digits Drawing Data Affix a modulus 10 C D Affix price C D 5 digits Other than 15 digits Not to be drawn D8 D7 D6 D5 D4 D3 D2 D1 D12 D11 D10 D9 D14 D13 D15 D17 D16 D8 D7 D6 D5 D4 D3 D2 D1 D12 D11 D10 D9 D14 D13 D17 D16 D15 D8 D7 D6 D5 D4 D3 D2 D1 D12 D11 D10 D9 D14 D13 D15 D17 D1...

Страница 362: ...t Data To be checked as modulus 10 C D Drawing Data Other than 9 digits Not to be drawn 3 Auto affix of modulus 10 No of Input Digits Input Data 8 digits Drawing Data Other than 8 digits Not to be drawn D7 D6 D5 D4 D3 D2 D1 D9 D8 D7 D6 D5 D4 D3 D2 D1 0 D9 D8 D7 D6 D5 D4 D3 D2 D1 D9 D8 D7 D6 D5 D4 D3 D2 D1 0 D9 D8 Calculate and reflect modulus 10 C D in the bar code D6 D5 D4 D3 D2 D1 D8 D7 C D D6 D...

Страница 363: ...C D Drawing Data Other than 12 digits Not to be drawn 3 Auto affix of modulus 10 No of Input Digits Input Data 11 digits Drawing Data Other than 11 digits Not to be drawn D7 D6 D5 D4 D3 D2 D1 D9 D8 D10 D12 D11 D7 D6 D5 D4 D3 D2 D1 0 D9 D8 D11 D10 D12 D7 D6 D5 D4 D3 D2 D1 0 D9 D8 D11 D10 D12 D7 D6 D5 D4 D3 D2 D1 D9 D8 D10 D12 D11 Calculate and reflect modulus 10 C D in the bar code D6 D5 D4 D3 D2 D...

Страница 364: ... to be drawn 4 IBM modulus 10 Auto affix of IBM modulus 10 No of Input Digits Input Data Max 13 digits Drawing Data Affix IBM modulus 10 Affix IBM modulus 10 14 digits or more Not to be drawn 5 IBM modulus 11 Auto affix of IBM modulus 10 No of Input Digits Input Data Max 13 digits Drawing Data Affix IBM modulus 10 Affix IBM modulus 11 14 digits or more Not to be drawn D8 D7 D6 D5 D4 D3 D2 D1 D10 D...

Страница 365: ...e Not to be drawn 3 Auto affix of modulus 10 No of Input Digits Input Data Max 125 digits Drawing Data Affix a modulus 10 C D 126 digits or more Not to be drawn 4 Auto affix of DBP modulus 10 No of Input Digits Input Data Max 125 digits Drawing Data Affix a DBP modulus 10 C D 126 digits or more Not to be drawn D7 D6 D5 D4 D3 D2 D1 D9 D8 D7 D6 D5 D4 D3 D2 D1 C D D9 D6 D8 D7 D6 D5 D4 D3 D2 D1 D9 D7 ...

Страница 366: ... Input Data To be checked as a modulus check character including C D Drawing Data 1 digit 127 digits or more Not to be drawn 3 Auto affix of modulus check character No of Input Digits Input Data Max 125 digits Drawing Data Affix a modulus check character 126 digits or more Not to be drawn D7 D6 D5 D4 D3 D2 D1 D9 D8 D7 D6 D5 D4 D3 D2 D1 C D D9 D6 D8 D7 D6 D5 D4 D3 D2 D1 D9 D7 D6 D5 D4 D3 D2 D1 D8 D...

Страница 367: ...ode Stop code To be checked as modulus 43 C D including C D Drawing Data 1 digit 124 digits or more Not to be drawn 3 Auto affix of modulus 43 No of Input Digits Input Data Start code Stop code Max 122 digits Drawing Data Affix a modulus 43 C D 123 digits or more Not to be drawn D8 D7 D6 D5 D4 D3 D2 St D1 Sp D9 D8 D7 D6 D5 D4 D3 D2 St D1 Sp D9 D8 D7 D6 D5 D4 D3 D2 St D1 Sp D9 D8 D7 D6 D5 D4 D3 D2 ...

Страница 368: ...t code Stop code Max 60 digits Drawing Data Affix a modulus 43 C D 61 digits or more Not to be drawn NOTE Numerals under bars are not characters corresponding to the bars but the characters of the codes received are drawn Type of Bar Code NW7 1 No affix C D check Auto affix No of Input Digits Max 125 digits Input Data Start code Stop code Drawing Data 126 digits or more Not to be drawn D8 D7 D6 D5...

Страница 369: ...0H to US 1FH FNC1 FNC2 FNC3 SHIFT CODE A CODE B CODE C Type of Bar Code Auto selection of CODE128 1 No affix C D check Auto affix of C D No of Input Digits Input Data Max 60 digits Drawing Data Stop code Start code Selection code Affix PSEUDO103 C D 61 digits or more Not to be drawn NOTE The following characters are not drawn as numerals under bars NUL 00H to US 1FH FNC1 FNC2 FNC3 SHIFT CODE A COD...

Страница 370: ...corresponding to the bars but the characters of the codes received are drawn Type of Bar Code UCC EAN128 1 No affix C D check Auto affix of C D No of Input Digits Input Data 19 digits Drawing Data Start code Affix a modulus 10 C D Affix a modulus 11 C D Stop code Other than 19 digits Not to be drawn D8 D7 D6 D5 D4 D3 D2 D1 D9 D8 D7 D6 D5 D4 D3 D2 St D1 Sp C D2 C D1 D9 D6 D5 D4 D3 D2 D1 D14 D15 D16...

Страница 371: ...t code Stop code 12 digits Drawing Data Start code Stop code Dedicated check digit 13 digits or more Not to be drawn Type of Bar Code KIX CODE 1 No affix No of Input Digits 18 digits Input Data Drawing Data 19 digits or more Not to be drawn D5 D4 D3 D2 D1 Sp C D D5 D4 D3 D2 D1 St D5 D4 D3 D2 D1 Sp C D D5 D4 D3 D2 D1 St D9 D8 D7 D6 D9 D8 D7 D6 D5 D4 D3 D2 D1 D9 D8 D7 D6 D11 D10 D4 C D D5 D3 D2 D1 S...

Страница 372: ...edicated C D No of Input Digits 13 digits Input Data Drawing Data Dedicated check digit 14 digits or more Not to be drawn Type of Bar Code GS1 DataBar Expanded GS1 DataBar Expanded Stacked 1 Auto affix of dedicated C D No of Input Digits 74 digits Input Data Drawing Data Dedicated check digit 74 digits or more Not to be drawn NOTE Some data cannot be drawn even if the number of input digits is les...

Страница 373: ...345ABC Standard 12345ABC Full ASCII J12345ABC 12345ABC Standard 12345ABC Full ASCII 12345ABC 12345ABC Standard 12345ABC CODE 39 Add start code Full ASCII J12345ABC 12345 ABC Standard 12345 ABC Full ASCII 12345 JABC 12345ABC Standard 12345ABC Full ASCII J J12345ABC 12345ABC Standard 12345ABC Full ASCII J12345ABC J 12345 ABC Standard 12345 ABC Full ASCII J12345 JABC 12345ABC Standard 12345ABC Full A...

Страница 374: ...345678 a12345678a a12345678 a12345678 12345678c 12345678c Omit b12345678d b12345678d No designation 12345a678 a12345a678a ab12345678 ab12345678 a12345678bc a12345678bc d12345b678c d12345b678c 12345678 a12345678 a12345678 aa12345678 12345678c a12345678c Add start code b12345678d ab12345678d 12345a678 a12345a678 ab12345678 aab12345678 a12345678bc aa12345678bc d12345b678c ad12345b678c NW7 12345678 12...

Отзывы: