background image

1/15 

 

B-EX700-RFID-H3-QM-R Installation Manual

 

 

 

Thank you for purchasing TOSHIBA TEC HF RFID kit, B-EX700-RFID-H3-QM-R. 
The B-EX700-RFID-H3-QM-R is exclusively for the B-EX4T1-GS12/TS12-QM-R. 
This unit must come together with B-EX904-R-QM-R Ribbon Saving Module during installation. 
This RFID kit complies with radio laws of all applicable countries. 
As this product is a wireless communication device, please be sure to read the following 
precautions carefully. 

 

WARNING!

 

1. 

Do not use a printer embedded with this product near medical equipment. Radio wave emitted 
from this  product may affect the operation of medical equipment, such as an implanted 
cardiac pacemaker and  implantable cardioverter-defibrillator.

 

If a use of this product should be likely to have affected medical equipment, immediately 
turn  off  the  product and contact your TOSHIBA TEC sales agent.

 

Keep a printer embedded with this product at least 23cm away from a person with an implanted 
cardiac pacemaker or implantable cardioverter-defibrillator.

 

2. 

Do not export a printer embedded with this product to the countries or areas where a use of this 
product is  not allowed, without permission.    Doing so is against the law, and you may be 
punished.

 

When exporting this product, check the laws and regulations of a destination country and take 
necessary procedures.

 

3. 

Follow all manual instructions.    Failure to do so could create safety hazards such as fire or 

electrocution.

 

 

Manual instructions must be followed when installing option kits or adding cables to avoid 
system  failures and to insure proper performance and operation.

 

 

Failure to follow manual instructions or any unauthorized modifications, substitution or 
change to this  product will void the limited product warranty.

 

4. 

Turn the power OFF and disconnect the power cord before installing the RFID module.

 

5. 

Be careful not to pinch your fingers or hands with the covers.

 

6. 

The print head and stepping motor becomes very hot immediately after printing.    Do not touch 

the print  head, stepping motor and around it right after printing, or you may get burned.

 

7. 

When opening the top cover, it must be fully opened.    Failure to do this may cause the top cover 

to close  under its own weight, resulting in an injury.

 

 
 

2/15 

 

1. 

APPLICABLE MODEL 

(1) 

This optional device is intended for the following 

models: B-EX4T1-GS/TS12-QM-R 
Be careful not to install this product in any other models than above. 

(2) 

The countries where the use of this device is allowed are as follows: 

 

Module Name

Frequency Band

Applicable Countries 

TRW-HFM-01 

HF 13.56 MHz 

Korea 

 
 

2. 

PACKING LIST 

All the following parts are supplied with the kit.  Make sure you have all items shown below.  
If any part is missing, please contact your TOSHIBA TEC sales agent.

 

 

 

Antenna Unit (1 pc.)

 

 RFID R/W Module (1 pc.) 

 

 Ribbon Guide (1 pc.) 

 

 

 Interface Cable (1 pc.) 

 

 

 Cord Bush (1 pc.) 

 

 Antenna Cable (1 pc.) 

 

 

 Double-Sems Screw  

SMW-3x6 (1 pc.) 

 

 

 

 Tapping Screw  

PT-3x6 (5 pcs.) 

 

 R/W Module Attachment Plate 

(2 pcs.) 

 
 



 

Earth Plate (1 pc.)

 

 

 



 Installation Manual (1 copy) 

Содержание B-EX700-RFID-H3-QM-R

Страница 1: ...e safety hazards such as fire or electrocution Manual instructions must be followed when installing option kits or adding cables to avoid system failures and to insure proper performance and operation Failure to follow manual instructions or any unauthorized modifications substitution or change to this product will void the limited product warranty 4 Turn the power OFF and disconnect the power cor...

Страница 2: ... the Side Panel L backward and raise it to remove from the printer B 4x5 Screw Side Panel L B 4x5 Screw 4 Fully open the Top Cover 4 15 Head Lever 5 Release the tab on the right end by pushing it then remove the Front Panel 3 2 Attaching the Ribbon Guide 1 Turn the Head Lever to the FREE position and gently open the Ribbon Shaft Holder Plate Front Panel Tab Ribbon Shaft Holder Plate ...

Страница 3: ...ing 4 Disconnect the Ribbon End Sensor Harness from the Ribbon End Sensor NOTE Keep the removed Ribbon Guide Shaft for future use Ribbon Guide Shaft Ribbon End Sensor Sensor Harness 6 15 5 Separate the Sensor PCB from the Sensor Frame 6 Fit the Sensor PCB into the Ribbon Guide 7 Connect the Ribbon End Sensor Harness to the Sensor PCB Sensor PCB Ribbon End Sensor Harness Ribbon Guide Sensor PCB Sen...

Страница 4: ...Antenna Unit Hook Ribbon Guide Shaft Antenna Cable Insert the front side first Ribbon Guide 8 15 Tip Align the four corners of the Antenna Unit to the notches indicated by the circles Platen Holder 2 As shown in the figure below hold the Antenna Unit so that the Antenna comes to the lower side and the antenna attachment position comes to the right hand side Then fit the Antenna Unit into the botto...

Страница 5: ...nd pass it through the inside of the Cable Guard Cable Guard Antenna Cable Main Frame Cord Bush Cord Bush 10 15 Interface Cable Screw PT 3x6 4 Secure two R W Module Attachment Plates with one screw PT 3x6 respectively 5 Connect the Interface Cable to the RFID R W Module and install it in the attachment plate with three screws PT 3x6 Screw PT 3x6 R W Module Attachment Plate RFID R W Module Screw PT...

Страница 6: ...NTER Contents of the RFID Menu Menu Sub menu Parameter RFID TEST ID READ MODULE MODULE TYPE COUNTRY TAG RF CHANNEL RETRY ADJ RETRY POSITION ISSUE RETRY LABELS READ RETRY WRITE RETRY UHF SETTING POWER LEVEL Q VALUE AGC THRESHOLD WRITE AGC THRESHOLD WRITE RETRY MIN AGC OTHER TAG CHECK MULTI WRITE CARRIER SENSE These items cannot be set in this kit Key functions in the system mode Key Function MODE R...

Страница 7: ... U4 US EU R U4 module preinstall model B EX4T1 EX4T2 GS18 TS18 CN R Tip This setting will become effective after the printer power is turned off and then back on 2 COUNTRY This is not available Do not use this module ID READ TAG 1 1 00010203 04050607 The number of the tag is being read The total number of tags d The data of the read tag are displayed in hex 14 15 3 TAG None ISO15693 4 CHANNEL This...

Страница 8: ...e data onto an RFID tag The printer retries to write data onto an RFID tag for up to the specified number of times If the timeout period expired before the maximum number of retries have been done the printer stops the retries at this time Default value 5 times Write retry timeout Set the timeout period during which RFID tag write retries are allowed with the UP or DOWN key If the printer has retr...

Отзывы: