background image

1129850201

OWNER’S MANUAL

AIR CONDITIONER (SPLIT TYPE)

For general public use

Indoor unit

RAS-B10, 13, 16N4KVRG-E

Outdoor unit

RAS-10, 13, 16J2AVSG-E1

ENGLISH

ENGLISH

R32 or R410A

Содержание 16J2AVSG-E1

Страница 1: ...1129850201 OWNER S MANUAL AIR CONDITIONER SPLIT TYPE For general public use Indoor unit RAS B10 13 16N4KVRG E Outdoor unit RAS 10 13 16J2AVSG E1 ENGLISH ENGLISH R32 or R410A ...

Страница 2: ...losion or injury do not operate the unit when harmful gases e g flammable or corrosive are detected near the unit WARNING Do not expose your body directly to cool or warm air for a long time Do not insert your finger or any article into the air inlet outlet When an abnormality burning smell etc occurs stop the air conditioner and disconnect the power supply or turn off the breaker This appliance c...

Страница 3: ...y or death CAUTION Do not wash the unit with water It may cause an electric shock Do not use this air conditioner for other purposes such as preserving food breeding animal etc Do not step or put anything on the indoor outdoor unit It may cause an injury or damage the unit Do not touch aluminium fin because it may cause an injury Before cleaning the unit turn off the main switch or the circuit bre...

Страница 4: ...irection 2 Press FIX Move the louver in the desired horizontal direction 3 V V H H H DA Swing off Vertical Up Down Swing Vertical and Horizontal Swing Horizontal Left Right Swing HADA CARE FLOW SWING operation can be selected from MENU button MENU Vertical Up Down swing Horizontal Left Right swing HADA Care flow Note Do not move the louver manually by hands or others The louver may automation posi...

Страница 5: ... Flow Operation Setting 1 Press MENU button for enter menu selection MENU C Blink During triangle mark blink can select menu by press TEMP button 2 Enter Louver set by press MENU button again triangle mark will stop blink and setting feature will be blink instead C Blink MENU 3 Select Louver swing or HADA CARE FLOW by press TEMP button C V V H H H DA Swing off Vertical Up Down Swing Vertical and H...

Страница 6: ...rk will stop blink and setting feature will be blink instead C MENU 3 Select SILENT operation by press TEMP button C SILENT 1 SILENT 2 None 4 Confirm selected feature by press MENU button again MENU C Blink only triangle Feature already set When feature had selected will return to menu selection display triangle mark will blink 5 Leave from menu setting display by select EXIT MENU C 9 3 Hi POWER O...

Страница 7: ...splay by select EXIT MENU C Note While Fireplace operation on heating mode indoor unit fan always runs and cold air breezing might be occurred Fireplace will operate in Heating mode only 9 6 TIMER OFF OPERATION To set the timer OFF when the air conditioner is operating 1 Press MENU button for enter menu setting and press TEMP button to select TIMER OFF MENU C Blink both triangle and feature mark F...

Страница 8: ...lamp brightness or turn it off 1 Press and hold FAN for 3 seconds until brightness level or is shown on remote control LCD then release the button 2 Press Rise or Decrease to adjust brightness in 4 levels Remote control LCD Operation display Brightness Lamp illuminates full brightness 100 Lamp illuminates 50 brightness 50 Lamp illuminates 50 brightness and the operation lamp is turned off 50 All l...

Страница 9: ...ing capacity Heat is absorbed from outdoors and released into the room When the outdoor temperature is too low use another recommended heating apparatus in combination with the air conditioner 6 Consideration for accumulated snow Select the position for outdoor unit where it will not be subjected to snow drifts accumulation of leaves or other seasonal debris 7 Some minor cracking sound may occur w...

Страница 10: ...ersion 5 0 or later iOS 9 0 or later About Toshiba Home AC Control 1 Toshiba Home AC Control can control AC operation by Smartphone or tablet mobile device via internet connection 2 Everywhere control control software run on Cloud system and mobile device can set and monitor AC operation via internet connection 3 Everyone can control 1 Wireless adapter maximum 5 User use 1 email register 4 Multi A...

Страница 11: ... for active AP mode 2 In case of change Wireless adapter to use with other A C need to factory reset and re process for add Wireless adapter again Build in type Press MODE button at Remote controller 5 seconds and select rb Build in type Wireless adapter already install with unit Wi Fi LED 2 Open application and select Log in 3 Enter user name and password 4 Login successful 1 Connect Wireless ada...

Страница 12: ...nnect Press and hold MODE button 5 seconds WPS mode Manual input Wireless LED mark will blink when AP mode active 4 Active Wireless adapter by Remote controller 5 Connect with Home Wi Fi Router 6 A C add finished 7 Connect successfully Wireless LED lamp stop blink Add Wireless adapter for control by Toshiba Home AC Control application ...

Страница 13: ... Weekly schedule Setting Sub menu all AC Add Group Delete Group Operation Setting Add AC Sub menu group Select AC Change group name Group operation Setting Sub menu AC Operation Setting Change name Delete AC Setting temperature Actual room temp Current operation mode of each AC Toshiba Home AC Control application Home screen ...

Страница 14: ... Off Auto Heat Enter operation mode of All AC Enter operation mode of Group AC Enter operation mode of each AC Mode and Condition setting Mode select for Toshiba Home AC Control application Provide for 5 operation modes ...

Страница 15: ...schedule OFF ON Timer set OFF ON timer set 0 5 12hrs ON timer set from Off mode only Off mode Mode select Temperature set Indoor temperature Outdoor temperature Fan speed set Special feature Louver set Setting in operation mode ...

Страница 16: ...Add AC in group Delete AC in group Maximum 3 groups 1 Group maximum 10 units Add group Group operation ...

Страница 17: ...elect box Weekly schedule set and active Weekly schedule set but not active Weekly schedule not set Weekly schedule set for each unit Day select Monday Sunday Weekly schedule of all AC unit Weekly schedule of all AC unit Weekly schedule set Weekly schedule cancel ...

Страница 18: ...Select Room for Energy monitoring 1 Select Energy monitoring 2 Energy monitoring display Set cost calculate and currency Select Energy monitoring display Export data and send by Email Energy monitoring ...

Страница 19: ...r must be installed maintained repaired and removed by a qualified installer or qualified service person Contact dealer and or service center when equipment is malfunction In case of have some problem can check from Help menu ...

Страница 20: ......