141 / 177
Copyright © 2018 - 2020 Toshiba Teli Corporation, All rights reserved.
https://www.toshiba-teli.co.jp/en/
DAA00195C
LUTControl
This function allows you to apply the
arbitrary
LUT (input: 12it, output: 12bit) to the output images.
example of LUT setting
● GenICam Node
Name
Interface
Length
Byte / [bit]
Access
Description
LUTEnable
IBoolean
4
R/W
Sets the activation of LUT function.
LUTIndex
IInteger
4
R/W
Sets the input level of LUT.
LUTValue
IInteger
4
R/W
Sets the output level of LUT.
● IIDC2 Register
Register
Field
Address
Length
Byte / [bit]
Access
Description
LUTEnable
Implemented
0x206020
[31]
R
Returns the state whether the function is implemented.
Value
0x20603C
4
R/W
Sets the activation of LUT function.
[0] : Off
[1] : On
LUTValueAll
Implemented
0x2FFFDC
[31]
R
Returns the state whether the function is implemented.
Value[0]
0x300000
4
R/W
Sets the output level of LUT.
Value[1]
0x300004
4
R/W
Sets the output level of LUT.
Value[2]
0x300008
4
R/W
Sets the output level of LUT.
…
…
…
…
…
Value[4095]
0x303FFC
4
R/W
Sets the output level of LUT.
Output
luminance
Input
luminance
Binarization