background image

WM Series Manual

Warning:

User is responsible for installing this unit in accordance with all 

local, provincial/state and federal electrical code requirements. 

The installation of this unit requires inspection and approval 

by local safety authority. This wall mount unit is not equipped 

with a power safety interlock.

Содержание WM 100 BAL TVSS

Страница 1: ...ling this unit in accordance with all local provincial state and federal electrical code requirements The installation of this unit requires inspection and approval by local safety authority This wall mount unit is not equipped with a power safety interlock ...

Страница 2: ......

Страница 3: ...tection ThermalProtection Circuit Schematic North American WM Model Layout North American WM Model Electrical Specifications North American Models Electrical Specifications International Models Mechanical Specifications North American Models Mechanical Specifications International Models Wall Cabinet External Layout WM Series Warranty Page 1 Page 2 Page 2 Page 2 Page 3 Page 3 Page 3 Page 3 Page 3 ...

Страница 4: ... socket or fused strip and where the cord exits the device 9 Periods Of Non Use The device should be unplugged when not being used for extended periods 10 Dangerous Entry Care should be taken that no foreign objects or liquids fall or are spilled inside the device 11 Service The device should always be serviced by licensed technicians Only replacement parts specified by the manufacturer should be ...

Страница 5: ...0V input to 120V to power equipment Where 240V balanced input is unavailable units may be configured for 208V operation PIUs use ZeroSurge patented series mode surge removal filters to absorb dangerous voltage surges and safely dissipate them without using failure prone MOVs metal oxide varistors Also unlike MOV based protection voltage surges are not shunted to ground Isolation is combined with p...

Страница 6: ...0VAC TYPE J use LPJ 25SP or JDL25 in holder JT60030 AWG 18 to 8 TORQUE to 2 3Nm 20 lb in FUSE 15A FA 250VAC 31 75mm X 6 35mm 2 POLE CONTACTOR 30A 600VAC COIL 208 240VAC OUTPUT NEUTRAL TERMINAL BLOCK OUTPUT GROUND TERMINAL BLOCK AWG 16 to 6 TORQUE 2 0Nm 18 lb in T1 TS1 PCB1 CB1 CB3 A4 A5 F1 F2 F3 F4 F5 F6 K1 TB1 TB3 TB4 TB6 TB1 TB6 CUSTOMER WIRING CONNECTIONS INPUT MAINS SUPPLY OUTPUT TO LOAD EQUIP...

Страница 7: ...S F6 F5 15A 15A F5 2 F6 2 F5 1 F6 1 TVSS CB1 CB3 CB2 20A 20A 20A 2 0A 2 0A OUTPUT GND K1 1 L1 3 L2 L1 L2 T 1 2 T 1 3 T 1 4 T 1 5 T 1 6 T 1 7 T 1 8 T 1 9 T1 9 1 T1 9 2 T 1 9 B T 1 9 B 1 T 1 1 0 T 1 1 0 1 T 1 1 0 2 T 1 1 0 A 2 INPUT 1 N L1 L2 TS1 T1 2 T1 4 T2 THERMAL SWITCH N C 120VAC 240VAC 1 2 F F L T L T F3 F4 F3 1 F4 1 F3 2 F4 2 CB2 2 CB2 1 CB1 2 CB1 1 TB1 2 TB2 2 TB4 2 TB5 2 TB1 1 TB2 1 TB4 1 T...

Страница 8: ... Output Circuit Breakers Maximum Available Output Current WM 30 220 240VAC 50 60Hz 220 240VAC NO 2x30A Fuses 3x15A 30A WM 45 2x45A Fuses 5x15A 45A WM 30 TVSS 220 240VAC 50 60Hz 220 240VAC YES 2x30A Fuses 3x15A 30A WM 45 TVSS 2x45A Fuses 5x15A 45A Model Number Weight KG lb Size mm HxWxD Size inch HxWxD Construction WM 45 BAL 74 5 164 673x526x261 26 5x20 7x10 3 NEMA TYPE 1 Enclosure 14 guage steel B...

Страница 9: ... 7 Wall Cabinet External Layout WM AVR Series 25 50 24 37 10 25 14 00 10 250 Space around unit as shown above Customer electrical connections A 5 00 B 6 00 Wiring conduit holes should be added as required to this area B A A A ...

Страница 10: ...ing to Torus Power Inc for warranty repair is is the responsibility of the customer Warranty coverage is not transferrable and original proof of purchase is required for warranty claims In the event of a warranty claim Torus Power Inc will remedy the issue by repair or replacement as we deem necessary to restore the product to full performance This warranty is considered void if the failure of the...

Страница 11: ......

Страница 12: ...Rev 11 02 2016 ...