System Setup 

Click the 

Setup

 text for a specific AVR Elite device to view and edit operational setting of the device. Click 

the 

Save Setup

 

text bar for changes to be saved on the AVR Elite. 

 

Out of Range Voltage – when this box is checked the AVR Elite will automatically turn off when the 

incoming voltage is above or below the acceptable range. 

 

Zone R/Router Reset – there is a single outlet on the back of the AVR Elite labelled as zone ‘R’. When 

this box is checked the outlet should only be used to power a network router or switch. Power to 

this outlet will automatically cycle when the AVR Elite detects a loss of internet connectivity. 

When this box is checked Zone R state can no longer be controlled through Zone Control (it will not 

be shown as one of the zones) and it can not have a schedule assigned for automatic on/off control. 

 

Router Reset Delay Time – enter the time (in minutes from 1 to 255) that Zone R outlet power 

should be cycled if the initial power cycle failed to restore internet connectivity. This power cycle 

will be attempted a maximum of three time. This setting requires the Zone R/Router Reset box to be 

checked. 

 

Delay Time between Zones – enter the time (in seconds from 1 to 999) for delay between the 

sequential power up of zones when the AVR Elite unit is turned on or multiple zones are turned on 

at the same by a schedule. 

 

Front Panel Display – choose between 3 modes; 

o

 

Always ON when the AVR ELITE is powered on 

o

 

Automatically DIM when the delay time expires (10-255 seconds) 

o

 

Automatically turn OFF when the delay time expires (10-255 seconds) 

For the automatic dim and off options the display will turn ON when the AVR ELITE is powered 

ON or the small pushbutton below the LCD display is pushed. 

 

Schedule – when this box is checked the outlets for each zone can be controlled automatically by a 

schedule (see Manage Schedule). 

 

Device Time Zone – enter the value relative to GMT for the location of the AVR Elite (e.g. enter -5 for 

Eastern Standard Time, -8 for Pacific Standard Time, ….) 

 

Device Time – this displays the current local date and time at the AVR Elite. 

Содержание AVR ELITE 15

Страница 1: ...AVR ELITE Series Owner s Manual O ...

Страница 2: ...rough the toroidal isolation transformer using patented Narrow Bandwidth Technology The toroidal isolation transformer provides high levels of instantaneous current making sure even dynamic components such as high power amplifiers are never starved for power It s like having a clean power source directly adjacent to the plugged in components Torus Power isolation transformers also protect connecte...

Страница 3: ...cations 10 North American Models 10 International Models 11 Circuit Schematics 12 AVR ELITE Embedded Software 15 Username and Password 15 AVR ELITE Menu Selections 16 Torus Power Connect 20 User Registration 21 Device Registration applies to Self Registered Users only 21 User Menu 22 System Status 22 Live Data 23 Power Control 24 System Setup 25 Historical Charts 27 Historical Data 29 Schedule 31 ...

Страница 4: ... of fatal shock 6 Ventilation The device should always be located in such a way that it maintains proper ventilation It should never be placed in a built in installation or anywhere that may impedethe flow of air through its ventilation slots 7 Heat Never locate the device near heat sources suchas radiators floor registers stoves or other heat generating devices 8 Power Cord Protection Power cable...

Страница 5: ...the equipment is used in a manner not specified by the manufacturer the protection provided by the equipment may be impaired 15 The power switch should be in the off position when connecting or disconnecting equipment from a Torus Power unit 16 CAUTION Some units can be very heavy please use safe practices when lifting ...

Страница 6: ...tall the unit directly above heat generating equipment Maintain at least 6 behind the PIU for adequate wiring space Warranty Torus Power Inc products are warranted to be free from manufacturing defects as follows Five years from the original date of sale for toroidal transformers Two years from the original date of sale for all other components The product warranty includes parts labour and return...

Страница 7: ...t life with worst case catastrophic events destroying valuable equipment In such real world conditions the Torus Power AVR ELITE can protect your equipment and improve the quality of your audio and video experience Series mode surge suppression is built into each AVR ELITE to provide protection against lightning strikes and other power disturbances meeting IEEE endurance standards of 6000 volts 30...

Страница 8: ...e AVR ELITE the System Status will appear Each time you push the button it will change from one information screen to another Time Day Date System Status Power Status IP and MAC Address IMPORTANT NOTE The following screen is shown but does not apply to the AVR ELITE models which do not have individual outlet zones It will indicate all zones as ON or OFF Individual zone control is available on AVR ...

Страница 9: ...wer again Nominal Input Output Fully Regulated Output Range Auto Shutdown Low Input Voltage Auto Shutdown High Input Voltage Output Range Before Auto Shutdown Fully Regulated Input Range Auto Turn On Low Input Value Auto Turn On High Input Value North American 120 120 4V 116 124 85 135 110 130 90 130 90 130 Notes 1 The AVR ELITE unit with SMSS option need to be switched ON at all times for series ...

Страница 10: ...ding of the load It doesnot indicate the peak current loads 5 A drop in the input voltage is normal when increasing the load on the AVR ELITE This is a result of the impedance of the power line a function of the distance from the electrical panel and transformer regulation ...

Страница 11: ... TOT AVR ELITE 10 TOT AVR ELITE 10 SMSS AVR ELITE 15 AVR ELITE 20 TOT AVR ELITE 4 CE TOT AVR ELITE 4 CE SMSS The full output current of the AVR ELITE is available from any outlet If for example the equipment connected to an outlet draws 5 amps then in the case of an AVR ELITE 20 there is 15 amps still available for equipment connected to any of the other outlets ...

Страница 12: ... ON the AVR ELITE and removing the 12 volts turns it OFF Requires a 3 5 mm TS type male audio connector with tip wired as positive and sleeve wired as negative from controlling source 12VDC Fault Output The AVR ELITE provides a 12 volt fault output through a jack on the back panel The output goes to 12 volts when a relay or voltage fault is detected The maximum current that can be drawn from this ...

Страница 13: ...20A Inlet NEMA C20 10 Medical Grade Outlets 15A N5 15 14AWG C13 15A 125V 483x483x203 17x19x8 40 5 89 2U 4 AVR ELITE 20 IEC 20A Inlet NEMA C20 10 Medical Grade Outlets 20A N5 20 12AWG C19 20A 125V 483x559x249 17x22x9 8 63 139 4U 8 TOT AVR ELITE 10 IEC 15A Inlet NEMA C14 10 Medical Grade Outlets 15A N5 15 14AWG C13 15A 125V 31 8 x 36 8 x 10 2 12 5 x 14 5 x 4 16 35 3 2U 4 TOT AVR ELITE 10 SMSS IEC 15...

Страница 14: ... Rear Panel Output Connector Rear Panel Line Cord Size cm WxDxH Size inch WxDxH Weight Kg lbs Chassis Height TOT AVR ELITE 4 CE IEC 15A Inlet NEMA C14 SCHUKO CEE 7 7 10A 250VAC 2 5M Plug CEE 7 7 Connector IEC C13 43 2 x 48 3 x 10 2 17 x 19 x 4 24 5 54 2U 4 TOT AVR ELITE 4 CE SMSS 25 55 Surge Suppression Series Mode Surge Suppression SMSS SMSS non sacrificial surge suppression can added to provide ...

Страница 15: ...12 P a g e Circuit Schematics North American TOT AVR ELITE 10 Model ...

Страница 16: ...13 P a g e TOT AVR ELITE 4 CE Model ...

Страница 17: ...ton switch for approximately 30 seconds and then release the pushbutton switch 5 Use the pushbutton as you would normally to scroll through the various screens until you get to the IP address screen and it should now show as 0 0 0 0 6 Plug in the Ethernet cable The IP address should change to a value appropriate for your new network setup as the unit s network configuration is now set to factory d...

Страница 18: ...en 2 Use a three way DHCP Router You then connect both PC and AVR ELITE to the same DHCP Router Open a browser window from the PC Type AVR or the IP address displayed on the LCD into the browser window Press ENTER and the software will open Username and Password The password is required to change the setup of the Torus unit Username admin The username is factory set and cannot be changed Password ...

Страница 19: ...word required to monitor status IMPORTANT NOTE This AVR ELITE model does not have individual outlet zones It will indicate all zones as ON or OFF Switch Main Power This screen allows ON OFF control of the AVR ELITE unit Press the SET button to implement your selection As the output power from the Torus AVR ELITE unit is shut down all the connected equipment is turned off The AVR ELITE main power s...

Страница 20: ...confirm your settings are correct Date and Time Setup When the AVR ELITE is connected to the Internet the date time and day will automatically be set However when the AVR ELITE has no access to the Internet the Date Time and Day can be set manually which will allow the AVR ELITE to follow scheduled programming even if the Internet is later unavailable If the Internet connection is restored the dat...

Страница 21: ...anel display Always ON default setting Dim after delay time 10 255 seconds expires Turn off after delay time 10 255 seconds expires When you have made your selection press SAVE SETUP IMPORTANT NOTE Only the Front Panel Display configuration options apply to this AVR ELITE model ...

Страница 22: ...ugh the web browser to automatically get an IP address from the network switch or router and this is the default setting and should work on most networks Some networks require each PC or device to use a fixed IP address and the AVR ELITE also supports this option The WiFi section is required when using the Torus Power Connect service Change Password If you wish to change the password use this scre...

Страница 23: ...Torus Power Connect provides Users with a custom dashboard for control status setup and configuration purposes One year of Torus Power Connect service is included with each new AVR Elite purchase A subscription renewal is required to continue this service beyond the first year Visit www toruspower com to purchase a 1 2 or 3 year subscription renewal ...

Страница 24: ...ler installer will get the required details to proceed with the registration and activation of this service for your AVR Elite and provide your account login details Device Registration applies to Self Registered Users only Each AVR Elite device to utilize the Torus Power Connect service by the dealer and or user must be registered There is a unique identifier called a MAC address for each AVR Eli...

Страница 25: ...available options Highlight and click to select the desired option see below for details of each option System Status Click the Show text for a specific AVR Elite device to view its system status details This will provide a snapshot of the values at the time of the request Clicking the Refresh text bar will update the System Status details every 3 seconds for 1 minute ...

Страница 26: ...for a specific AVR Elite device to easily view its input voltage output voltage input current output current and output Total Harmonic Distortion values Clicking the Refresh text bar will update the Live Data details every 3 seconds for 1 minute ...

Страница 27: ...e to manually control ON OFF the unit s power state or the power state of each individual outlet zone Click the Refresh Reported Values text to confirm the specific action was successful IMPORTANT NOTE Individual outlet zone power control is not available on this AVR ELITE model ...

Страница 28: ...ld be cycled if the initial power cycle failed to restore internet connectivity This power cycle will be attempted a maximum of three time This setting requires the Zone R Router Reset box to be checked Delay Time between Zones enter the time in seconds from 1 to 999 for delay between the sequential power up of zones when the AVR Elite unit is turned on or multiple zones are turned on at the same ...

Страница 29: ...26 P a g e ...

Страница 30: ...27 P a g e Historical Charts Click the Plot text for a specific AVR Elite device to Move the mouse cursor to one of the plot points to get the value and time for that data point ...

Страница 31: ...28 P a g e ...

Страница 32: ...st data values and the Requested Interval is the time period duration to be provided The data is listed chronologically in one minute intervals as the default sort order The data can be sorted by the values in any of the columns by clicking on the specific column header e g Output Voltage V The first click on the specific column header will sort the values from highest to lowest Clicking the same ...

Страница 33: ...30 P a g e ...

Страница 34: ... create a scheduled power on or off click the desired day then type in the hour and minutes 24 hour format or use the up down arrows to scroll to the desired value Check the box associated with each zone you wish to have power enabled at its outlets at that time WARNING Leaving a zone s box unchecked for a specific time will turn power off for all the zone s outlets at that time Click the Save Sch...

Страница 35: ...32 P a g e IMPORTANT NOTE Individual outlet zone power control is not available on this AVR ELITE model ...

Страница 36: ...t file or a fixed format pdf file The CSV format file can be imported into a spreadsheet software program such as Microsoft Excel so it can be manipulated to filter present the information in the desired format The pdf format file has information presented in a fixed report format The file is sent to the email address entered in the Dealer Information section ...

Страница 37: ...he Personal Information home screen shows the User s contact information submitted during the Torus Power Connect registration The User can use the Change Password text bar at any time to submit a new Torus Power Connect login password ...

Отзывы: