![background image](http://html1.mh-extra.com/html/toro/timecutter-zs-4200t/timecutter-zs-4200t_operators-manual_1132425007.webp)
•
Replace all parts including, but not limited to, tires, belts,
blades, and fuel system components with original Toro
parts.
•
Check the brake operation frequently. Adjust and service
the brake as required.
Model 74656
Sound Pressure
This unit has a sound pressure level at the operator’s ear of 89
dBA, which includes an Uncertainty Value (K) of 1 dBA.
Sound power level was determined according to the
procedures outlined in EN ISO 5395:2013.
Sound Power
This unit has a guaranteed sound power level of 100 dBA,
which includes an Uncertainty Value (K) of 1 dBA.
Sound power level was determined according to the
procedures outlined in ISO 11094.
Hand/Arm Vibration
Measured vibration level for right hand = 2.6 m/s
2
Measured vibration level for left hand = 3.2 m/s
2
Uncertainty Value (K) =1.6 m/s
2
Measured values were determined according to the procedures
outlined in EN ISO 5395:2013.
Whole Body Vibration
Measured vibration level = 0.82 m/s
2
Uncertainty Value (K) = 0.41 m/s
2
Measured values were determined according to the procedures
outlined in EN ISO 5395:2013 (Riding and Stand-Ons).
Model 74660
Sound Pressure
This unit has a sound pressure level at the operator’s ear of 94
dBA, which includes an Uncertainty Value (K) of 1 dBA.
Sound power level was determined according to the
procedures outlined in EN ISO 5395:2013.
Sound Power
This unit has a guaranteed sound power level of 105 dBA,
which includes an Uncertainty Value (K) of 1 dBA.
Sound power level was determined according to the
procedures outlined in ISO 11094.
Hand/Arm Vibration
Measured vibration level for right hand = 2.8 m/s
2
Measured vibration level for left hand = 3.5 m/s
2
Uncertainty Value (K) = 1.7 m/s
2
Measured values were determined according to the procedures
outlined in EN ISO 5395:2013.
Whole Body Vibration
Measured vibration level = 0.37 m/s
2
Uncertainty Value (K) = 0.18 m/s
2
Measured values were determined according to the procedures
outlined in EN ISO 5395:2013 (Riding and Stand-Ons).
7
Содержание timecutter zs 4200t
Страница 12: ...121 0772 1 Fast 4 Choke 2 Continuous variable setting 5 Power take off PTO blade control switch 3 Slow 12 ...
Страница 13: ...121 0773 1 Fast 4 Choke 2 Continuous variable setting 5 Power take off PTO blade control switch 3 Slow 13 ...
Страница 55: ...Schematics Electrical Diagram Rev A 55 ...
Страница 56: ...Notes 56 ...
Страница 57: ...Notes 57 ...
Страница 58: ...Notes 58 ...