Advisories Table (cont'd.)
Condition
Code
Qualifier
Display Text
Engine Stopped
103
Parking brake set
Engine stop due to parking
brake engaged
Pump Start Prevented
202
Boom active
To start pump, turn booms off
Pump Start Prevented
203
Out of seat and parking brake
not set
To start pump, must be seated
or set parking brake
Pump Start Prevented
204
Pump start when vehicle
stopped
To start pump, move vehicle
Pump Start Prevented
205
Engine starting
To start pump, stop cranking
engine
Pump Turned Off
206
Out of seat
To start pump, remain seated
Driving prevented
302
Parking brake engaged while
driving
To continue driving, release
parking brake
Tank Status
402
Low spray tank volume
Tank status, volume low
Tank Status
403
Rinse pump active
Tank status, rinse pump on
Parameter Status
502
Wrong parameter value entered
Parameter status, invalid value
Parameter Status
503
A value is outside the range of
accepted values
Parameter status, invalid data
defaults used
Booms Turned Off
802
Speed dropped
Booms turned off, stopped or
moving too slowly
GeoLink Configuration
902
GeoLink controller conflict
GeoLink Configuration, check
GeoLink controllers
GeoLink Configuration
903
InfoCenter setting
GeoLink configuration, check
InfoCenter settings
Flow Rate Meter
1002
No flow signal
Flow meter, no flow detected
Neutral switch
1102
Neutral switch signal
Neutral switch, motion while in
neutral
InfoCenter Fault Codes
Fault codes display on the InfoCenter screen when there is a problem with the electronic or computer systems.
For example, if the fuse for the Toro electronic controller is open, the InfoCenter displays fault code 1. Refer
to the fault code table for a list fault codes and recommended actions.
Fault Code Table
Fault ID
Affected Component or
System
Description
Recommended Action
1
Master Toro electronic
controller (TEC)
A signal to or from the Master
TEC are out of range.
Call your Authorized Toro
Service Distributor.
2
Output fuse
A fuse for the master TEC is
open.
Replace the fuse; refer to the
operator’s manual.
29