CE
Clear Entry
It clears a wrong entry; enables you to toggle between settings
during initial programming; and enables you to select functions
and settings.
TOTAL
AREA
Total area sprayed
It monitors the total area until you clear it to zero.
TOTAL
VOLUME
Total volume of material sprayed
It monitors the volume of material sprayed until you clear it to zero.
FIELD
AREA
Field area sprayed
It monitors the total area covered until you clear it to zero.
FIELD
VOLUME
Volume of material sprayed onto a
field or specific area
It monitors the volume of material applied until you clear it to zero.
DISTANCE Distance of vehicle travel
It measures the distance the vehicle travels until you clear it to zero.
SPEED
Vehicle speed
It displays the vehicle speed.
VOL / MIN
Volume of material sprayed per
minute at vehicle speed
It displays the volume/minute that the system is currently using.
AREA /
HOUR
Area sprayed per hour at vehicle
speed
It displays acres, 1000 sq. ft., or hectares covered per hour at the
vehicle speed driven.
DATA /
MENU
Area sprayed per hour at vehicle
speed
It allows you to adjust the agitation.
Note: When the number increases, the agitation pressure
increases. The number is not the agitation pressure.
It also allows you to use additional devices, such as a data loggers
and global positioning systems (GPS).
ENTER
Enter data
It allows you to enter data into the console computer.
*The calibration numbers listed are
for reference only
. Before spraying, check your sprayer to ensure the numbers
you are using are correct.
Operation
The console computer automatically controls the spray
application rate for varying vehicle speeds. You set the
target volume per unit area to spray and the console
computer automatically maintains the flow within the
proper range of the vehicle speed and continually
displays the actual volume of material per area sprayed.
The console computer also monitors the area sprayed,
the speed of the vehicle, and the total volume of
material sprayed.
Important:
A manual override switch allows
the operator to manually control the flow for the
system check out and spot spraying.
Note:
If the console computer malfunctions, you can
spray manually by unplugging the cables from the rear
of the console computer. You can then control the
spray application rate using the center console controls.
In this section, the procedure will use the following
naming convention:
•
The labels on the console computer keys are
enclosed in brackets. For example: Press the [Enter]
key.
•
The data you enter is in boldface type preceded by
the word
Press
. For example: Press
123
.
•
The data shown in the display is in normal type,
with letters in all caps.
Initially Programming the
Console Computer
You must first program the console computer before
you can use it to operate the spray system. You need
to perform this operation only when you turn on the
console computer for the first time.
Turn the power switch to the On position.
Note:
The console screen shows the message CAL in
the left hand window of the display.
Selecting US, SI, or TU
To select the units for US (volume per acre), SI (volume
per hectare), or TU (volume per 1,000 sq. ft.):
1. Press the [CE] key until you see your desired code
(US, SI, TU) in the display.
2. Press the [Enter] key.
The display now shows SP1.
11