Installation

Loose Parts

Use the chart below to verify that all parts have been shipped.

Procedure

Description

Qty.

Use

1

No parts required

Prepare the machine for installation.

Wire harness

1

Cable tie

8

Indicator light

1

Audio alarm

1

2

Spout

1

Prepare to install the leak detector tank.

Leak detector tank

1

Oil level sensor

1

O-ring

1

Valve hose

1

Tank valve hose

1

Hex-head bolt (1/4 x 2 inches)

2

Shield bracket

1

Hose clamp

4

Solenoid valve assembly

1

Straight fitting

1

90° hydraulic fitting

2

90° hydraulic fitting (beaded)

1

Delay timer (diesel model only)

1

Screw (5/8 inch)

1

Locknut

1

Oil level cover (diesel model only)

1

Oil level cover (gasoline model only)

1

Overflow hose

1

3

Worm-drive clamp

2

Install the leak detector tank.

© 2017—The Toro® Company
8111 Lyndale Avenue South
Bloomington, MN 55420

Register at www.Toro.com.

Original Instructions (EN)

Printed in the USA.

All Rights Reserved

*3419-997* A

 

Содержание 04730

Страница 1: ...s 1 Cable tie 8 Indicator light 1 Audio alarm 1 2 Spout 1 Prepare to install the leak detector tank Leak detector tank 1 Oil level sensor 1 O ring 1 Valve hose 1 Tank valve hose 1 Hex head bolt 1 4 x...

Страница 2: ...indicator and alarm leads in the console arm following the main wire harness under the seat to the other side of the machine and then behind the seat along the left hand rail so that the oil level se...

Страница 3: ...main hydraulic tank later 10 Remove the tank cover from the main hydraulic tank 11 Remove the plug from the hydraulic tank if equipped refer to Figure 4 g236699 Figure 4 1 Plug 2 Spout 12 Insert the...

Страница 4: ...ng to the main hydraulic tank Figure 7 g018539 Figure 7 1 Insert the 90 beaded hydraulic fitting here 4 Oil level cover 2 Shield bracket 5 Solenoid valve assembly 3 Hex head bolt 6 Install 1 end of th...

Страница 5: ...in hydraulic tank Figure 9 g016177 Figure 9 1 Remove plug from main hydraulic tank here 2 Indicator arrow on nut 2 19 Slide the O ring onto the hydraulic oil level sensor and install the sensor into t...

Страница 6: ...acteristics of your leak detector tank as follows If your leak detector tank has a sight window Fill the leak detector tank with hydraulic fluid until the fluid level is at the middle of the sight win...