Specifications
Note:
Specifications and design are subject to change
without notice.
AIR CONDITIONER
Cooling performance
4.2 kW
Refrigerant
R134A
Recommended quantity of refrigerant
850 g (1.87
lb)
Evaporator—volumetric air flow of the blower
660 m
3
/h
(23,307
ft
3
/h)
ELECTRICAL
Operating voltage
12 V
Fuse for radial blower / compressor
15 A
Fuse for axial blower
25 A
COMPRESSOR
Designation
TM-08 HS
Direction of rotation (viewing the pulley)
clockwise
Operating speed
700 to 6000
rpm
Piston displacement
82
cm
3
/rev (5
inch
3
/rev)
Pressure-side connection
3/4 inch
O-ring
Suction-side connection
7/8 inch
O-ring
Magnetic clutch operating voltage
12 V
Magnetic clutch power consumption
0.45 W
Refrigerant oil
ZXL 100
PAG
Refrigerant oil volume in compressor
150 cm
3
(9.15 inch
3
)
Refrigerant oil—additional required to fill
air-conditioner system
25 cm
3
(1.53 inch
3
)
Power consumption of air-conditioner system
2.5 kW
Attachments/Accessories
A selection of Toro approved attachments and accessories are
available for use with the machine to enhance and expand
its capabilities. Contact your Authorized Service Dealer or
Distributor or go to www.Toro.com for a list of all approved
attachments and accessories.
To best protect your investment and maintain optimal
performance of your Toro equipment, count on Toro genuine
parts. When it comes to reliability, Toro delivers replacement
parts designed to the exact engineering specification of our
equipment. For peace of mind, insist on Toro genuine parts.
Operation
Note:
Determine the left and right sides of the machine
from the normal operating position.
Using the Air Conditioner for
the First Time
1.
Start the engine.
2.
Switch on the blower switch (
).
3.
Switch on the air-conditioning switch (
).
4.
Set the temperature controller (
) to the
maximum Cold setting (full counterclockwise
direction).
Note:
After 3 minutes, the air-outlet louvers should
emit cold air.
5.
Adjust the fan speed and temperature control to
achieve the required amount of cooling.
Operating the Air-Conditioning
System
Do not run the air-conditioning system without running
the engine as it will not function and the battery will be
discharged.
To prevent premature failure of the compressor-shaft seals,
run the air-conditioning system for 15 minutes every 14 days.
1.
Set the switch to the O
N
position.
2.
Set the fan-speed switch to the desired speed.
3.
Set the temperature regulator to the required setting.
Note:
The thermostat in the system switches the
compressor on and off to maintain the set temperature.
Operating the Heating System
1.
Set the switch to the O
FF
position.
2.
Set the fan-speed switch to the desired speed.
3.
Set the temperature regulator to the required setting.
6
Содержание 02891
Страница 11: ...Schematics g01840 1 2 1 3 4 9 8 5 6 10 7 11...
Страница 16: ......