12
ATTENTION:
The machine and its battery check
card foresee the use of traditional
lead batteries.
CHECK SETTING OF THE
CHECK CARD ON THE INDI-
CATOR (1) (see under paragraph
"BATTERIES CHARGE LEVEL
INDICATOR").
In case of GEL batteries installa-
tion, it is necessary to set the bat-
tery check card. Please contact the
authorized technical assistance.
ATTENTION:
Strictly follow all manufacturer/
distributor directions for the main-
tenance and charging of the bat-
teries. Special staff, using suitable
protection accessories must execute
all installation and maintenance
operations.
For batteries installation it is neces-
sary to reach the battery compart-
ment as indicated under paragraph
“ACCESS TO THE BATTERY
COMPARTMENT”.
1. Open the recovery tank up to the
maximum opening position.
2. Place the batteries in the com-
partment.
3. Connect the terminals, paying
special to the polarities, avoiding
contact with other parts that could
create short circuit.
Battery charger
Be sure that the battery charger is
suitable for the installed batteries
both for their capacities and type
(lead/acid or GEL and equivalent).
Batteries charging
To charge the batteries it is neces-
sary to reach the battery compart-
ment as indicated under paragraph
“ACCESS TO THE BATTERY
COMPARTMENT”.
1. After disconnecting the batteries
from the unit, plug in the batteries
connector (1) placed in the inner
part of the machine, to the connec-
tor (3) of the battery charger.
2. Proceed with the charging keep-
ing the tank lifted.
ATTENTION:
Never charge a GEL battery with a
non-gel charger. Strictly follow the
instructions supplied by the batter-
ies and charger manufacturer.
To prevent permanent damage to
the batteries, it is necessary to
avoid their complete discharge Bat-
teries must be charged within a few
minutes after the battery discharge
signal starts blinking.
NOTE: Never leave batteries
completely discharged even if the
machine is not used. If using wet
lead batteries, please check the
electrolyte level every 2 weeks and
add distilled water as needed.
ATTENTION:
When charging the batteries it is
necessary to follow all directions
given by the manufacturer and/or
the distributor. Only qualified staff
must carry out all the installation
and maintenance operations. When
charging batteries there is a danger
of gas exhalations and emission
of corrosive liquids. There is also
a danger of fire, do not approach
with open flames.
Batteries disposal
It is mandatory to hand over ex-
hausted batteries, classified as
dangerous waste, to an authorized
institution according to the current
laws.
Batteries charge level indicator
TURNING THE KEY (9) CLOCK-
WISE, ON THE DISPLAY (1)
WILL CAUSE TO APPEAR, IN
SEQUENCE, THE FOLLOWING
INFORMATION:
1. The version (for example A003)
of software installed on the ma-
chine.
2. The setting of the battery check
card which can be for the 24V ver-
sion:
GE 24: check card set for GEL bat-
teries.
Pb 24: check card set for lead bat-
teries.
https://harrissupplyind.com - To Order Parts Call 608-268-8080