Tormax Automatic T-1165 Скачать руководство пользователя страница 1

T-2035 e  19.1.2021 

 

TORMAX | CH-8180 Bülach

Subject to technical changes!    

www.tormax.com | [email protected]

Supplement to the Operating Instructions:  
T-1165, T-1321

 

 

Area of application for drives:

TORMAX iMotion 2202, 2202.A, 2301, 2302, 2401 Sliding Door Drive 
TORMAX 2201, Sliding Door Drive

TORMAX count+go

3  Function of TORMAX count+go

The TORMAX count+go system counts and limits the traffic of people based on the door opening(s) in the entry and exit 
direction. The operator defines the permitted number of persons in the room via mobile phone or PC. When this number is 
reached, the current operating mode is switched to the operating mode EXIT. This ensures that people can leave the room 
at any time, but access is blocked. The system provides visual and/or acoustic support to inform the users.
The operator can call up detailed information from TORMAX count+go via mobile phone at any time and adjust it if necessary.
In order to reliably prevent unauthorised access when the room is closed, the TORMAX count+go system cannot be accessed 
in the operating mode OFF.

1  TORMAX count+go module
2  Load speaker
3  LED bar

Options:
4 Display
5 Barrier
6  Indicating sign

1

2

3

4

5

6

1

Contents

General Information 

1

System Overview 

1

Function of TORMAX count+go 

1

4 Applications 

2

5 Operation 

2

5.1   Activation of Passage Limitation 

2

5.2  Reset of the Passage Limitation 

2

Individual Settings 

3

1  General Information

This supplement to the operating instructions is only complete when read in conjunction with operating instructions T-1165 
or T-1321.

2  System Overview

6.1  Connection to the User Interface 

3

6.2   First Login/Change Password 

3

6.3   Settings 

5

6.4  Show Display/Screen 

7

6.5   Set Actual Counter/Reset 

8

7    Procedure in the Event of a Fault 

8

7.1   Reset 

8

7.2   Support 

8

Содержание T-1165

Страница 1: ...ers The operator can call up detailed information from TORMAX count go via mobile phone at any time and adjust it if necessary In order to reliably prevent unauthorised access when the room is closed...

Страница 2: ...he twentieth person passes through the door into the room The user interface changes from AUTOMATIC to EXIT The display and LED bar change to red and are flashing Entry is no longer possible 5 2 Reset...

Страница 3: ...AX count go module 6 2 First Login Change Password Open the browser and connect your device to http counter tx admin ATTENTION The browser Google Chrome is not recommended Note You may have to disable...

Страница 4: ...T 2035 e 19 1 2021 TORMAX CH 8180 B lach Subject to technical changes 4 www tormax com info tormax com Go to Password Fill in your own username and your new password Don t forget to Save it...

Страница 5: ...n make the following settings or alterations via the user interface Browser http counter tx admin Set maximum number of persons allowed In this case max 6 persons are allowed to enter and the actual n...

Страница 6: ...ave after any change Set Volume Example Change the volume of the loud speaker audio signal Always Save after any change Upload your own Audio files Save your audio files mp3 on your device Upload thes...

Страница 7: ...tx This page shows the green red display or open directly the link Display preview on the admin site Red display Green display 6 When Show counter value on screen is disabled the current counter stat...

Страница 8: ...ing the operating mode of the automatic door to OFF the counter will be set automatically to 0 Furthermore TORMAX count go will be shut down The LED and WLAN are off When changing the operating mode b...