16. Identify wires 503 and 504 on the ATC Legacy Adapter Cable.
Then, route them through the wire troughs toward the DC-
BUS board.
Figure 2-36: DC-BUS board in the electrical cabinet.
17. Connect wire 503 to the TC+ terminal on the DC-BUS board.
18. Connect wire 504 to the TC- terminal on the DC-BUS board.
Rewire the ATC Board
1. Unlock and open the lid on the ATC main assembly with a
large, flat-blade screwdriver.
2. Identify the J10 connector on the ATC board, and then unplug
it from the board.
Figure 2-37: J10 connector on the ATC board.
3. Identify the loose ends of wires 403, 408, and GND.
Figure 2-38: Loose wires on the J10 connector from the ATC
board.
4. Remove the plastic wire protectors from the ferrule ends.
5. Use a small, flat-blade screwdriver to connect the following
wires to the J10 connector:
l
Wire 408 to pin 3
l
Wire 403 to pin 4
l
Wire GND to pin 5
6. Plug the J10 connector back in the ATC board.
7. Close the lid on the ATC main assembly and lock it.
Verify the Installation
1. Power on the machine and the PathPilot controller.
a. Turn the Main Disconnect switch to
ON
on the side of the
electrical cabinet.
b. Twist out the Emergency Stop button on the operator
panel, which enables movement to the machine axes and
the spindle.
c. Press the Reset button on the operator panel.
d. Bring the machine out of reset and reference it.
2. If you have not yet done so, you must make sure that the
PathPilot controller is updated to the latest version of
PathPilot.
For information, see "Update PathPilot" (page 3).