INSTALLATION
5. Connect
wire 510
to the empty V- terminal on the power supply with a small, flat-blade screwdriver.
Figure 7: Wire 510 on the V- terminal on the power supply.
6. Re-seat the power supply onto the DIN rail, and then re-seat the security pin with a small, flat-blade
screwdriver.
7. Re-install wire troughs into the electrical cabinet.
Remove the Existing Z-Axis Motor
1. If you haven't yet done so, you must first power off the machine and the PathPilot controller.
WARNING!
Electrical Shock Hazard: You must power off the machine before making any electrical
connections. If you don't, there's a risk of electrocution or shock.
2. Power off the machine and the PathPilot controller.
a. Push in the machine's red Emergency Stop button, which removes power to motion control.
b. From the PathPilot interface, select
Exit
.
c. Turn the Main Disconnect switch to
OFF
on the side of the electrical cabinet.
d. Remove the power plug(s) from the wall outlet. If your system is hardwired, isolate the machine by
opening its circuit breaker(s).
e. Follow correct lockout/tagout procedures.
Page 10
©Tormach® 2022
Specifications subject to change without notice.
tormach.com
TD10801: Installation Guide: 24R Z-Axis Brake Retrofit Kit (0722A)