![Tormach 1300PL Скачать руководство пользователя страница 47](http://html.mh-extra.com/html/tormach/1300pl/1300pl_operators-manual_1130433047.webp)
5: SYSTEM BASICS
©Tormach® 2020
Specifications subject to change without notice.
Page 47
UM10720: 1300PL Operator's Manual (Version 0820B)
For the most recent version, see tormach.com/support
5.4 PLASMA SOURCE CONTROL
The 1300PL uses a 7-pin connector for controlling the plasma source. A 7-pin to 14-pin cable is included with your machine to control
Hypertherm plasma sources.
The pin-out of the 7-pin connector on the electrical cabinet is as follows:
Pin
Type
Signal
Notes
1
Output
Start Plasma
Dry contact closure. Closed relay signals plasma on.
2
3
Input
Arc Voltage -
An internal 50:1 voltage divider in the plasma source is
required
.
4
Arc V
5
Input
Arc-Ok
Expects dry contact closure at plasma source. Closed contacts signal arc-ok.
6
7
Not Used
The pin-out of the 14-pin Hypertherm connector on the end of the cable is as follows:
Pin
Type
Signal
Notes
3
Output
Start Plasma
Dry contact closure. Closed relay signals plasma on.
4
5
Input
Arc Voltage -
An internal 50:1 voltage divider in the plasma source is
required
.
6
Arc V
12
Input
Arc-Ok
Expects dry contact closure at plasma source. Closed contacts signal arc-ok.