TORAY MBR
Instruction Manual
06-G-MB2-NHPAF-220801
24 of 63
4. Piping
The procedures of the pipe arrangement for the air diffusers and the filtrate water manifold
are described in this section. The connections of the air diffuser and the filtrate water
manifold are shown in the module drawings attached to this manual.
(1) Pipe Arrangement for the Air Diffusers
The pipe from the air supply device (blower) is connected to the air diffusers with the
screws
(A) as shown in Fig.IV-9a, b, and c. It is recommended installing the flange connection (B)
above the liquid surface on this line in order to disjoint the piping in the case of lifting the
modules.
Fig.IV-9a Example of Piping to Air Diffusers for NHPA050-1F/100-1F
B
A
B
Air Diffuser
Header Pipe
PG
Air flow Meter