Table III-4 and III-5 shows the performance of ”NHPA Series” modules.
Table III-4 Filtrate water quality (Reference value)
Model name
All models
Filtrate
water
quality
*1
TSS (mg/L)
*2
Not higher than 3.0
Turbidity (NTU)
*3
Not higher than 1.0
*1 This value can be attained when operated under the standard operating conditions as specified in this
Instruction Manual
and Operation and Maintenance guideline during a period specified separately by
Toray.
*2 Measuring method of TSS is complied with Standard Method of Examination of Water and Wastewater
20
th
Edition (1998), Section 2540D, Total Suspended Solids Dried at 103-105 deg C or ISO 11923.
*3 Measuring method of NTU is complied with Standard Method of Examination of Water and Wastewater
20
th
Edition (1998), Section 2130, Turbidity or ISO 7027.
Table III-5 Flow capacity (Reference value)
Model name
NHPA050-1F
NHPA100-1F
NHPA150-1F
Filtration
Flow (m
3
/d)
*4
Sewage
3-25
7-50
10-75
Industrial wastewater
3-17
7-33
10-50
Model name
NHPA150-2F
NHPA150-3F
NHPA150-4F
Filtration
Flow (m
3
/d)
*4
Sewage
20 - 150
30-225
40 - 300
Industrial wastewater
20 - 100
30-150
40 - 200
*4 This value is just a reference value and not a guaranteed value of Toray. Sustainable operating filtration
flow capacity varies among the plant depending on the type of wastewater, total process design, and
operating condition. In case of industrial wastewater application, it is strongly recommended to conduct
a pilot test before membrane tank designing.