In order to control big power alternating current equipment, it is comfortable to use solid state relays.
6 INPUTS
The module PROGATE has:
2 analog inputs (In1, .In2 (0-
30V)) for analog sensors connection. Or can be used as security system‘s zones with selectable type:
NC/NO/EOL/EOL+TAMPER.
2 programmable analog inputs (I/O1, I/O2(0-
30V) for analog sensors control or using as security system‘s zone with selectable type:
NC/NO/EOL/EOL+TAMPER
Wiegand interface, RFID reader, Keyboard.
1 programmable digital inputs (D1(Max voltage 3.3V)) used for:
o
Dallas 1-Wire Bus. To connect temperature sensors DS18b20 or iButton key DS1990A,
o
Aosong 1-Wire bus Humidity Sensor AM2302, DHT22, AM2305, AM2306,
6.1
Input / zones wiring EOL NO NC
The module PROGATE has:
In1, In2, I/O1, I/O2 Can be used as inputs to
detect Gate position or security system‘s zones with selectable type: NC/NO/EOL/EOL+TAMPER.
It is recommended to use standard motion, fire, and glass breaking sensors. For powering of sensors we recommend to use standard 6-8
wires cable for, designed for installation of security system.
Connect sensors to module the as is shown in connection diagrams below
Set the required parameters
Write configuration by pressing [Write] button
Figure 23NC Contacts, No EOL
Figure 24 NC, With EOL
Figure 25 NO, With EOL
Figure 26NC With EOL Wire Fault
Recognition
All inputs has pull up resistors 10k
Refer to: Outputs. Bell & PGM programming
Refer to: Zones programming