PROGATE User manual V-2022-09-20
19 |
E N
5.1.2
Output programming
Output pulse counter
https://youtu.be/V9vt10q-o8Q
How to send commands to generate various pulse
lengths (5s, 10s)
https://youtu.be/KGvpfa38IUo
Quick start outputs
1.
Install SERA2 software. For more information look at
2.
Connect the module to the computer via mini USB cable. Device> PROGATE
3.
Go to Outputs (PGM) window in the SERA2 software
4.
Parameters of the selected output should be set:
output operation description (OUT definition): disable, bell, buzzer, flash, system state, ready, automation/ CTRL, AC OK, battery OK, ARM/ DISARM,
alarm indication, lost primary channel, lost secondary channel, fire sensor, RH sensor trouble.
5.
State type: flash, timer, steady mode.
6.
If necessary output operation might be inverted.
7.
Write configuration by pressing write icon
Figure 19 Outputs (PGM) window
If you want to edit existing configuration,
•
You have to read it (press “Read” in the command line)
•
Edit settings
•
Write edited configuration (press “Write” in the command line)
Outputs can be set as timers.
1.
When output is activated for “Out
Timer” time interval,
2.
Relay contact start changing state
from ON (pulse time ON) to OFF
(Pulse time Off)
3.
This cycle will repeat until output is
deactivated.
Output signal
Pulse time ON
Pulse time OFF
Pulse time ON
Pulse time OFF
Output state
Output ON
Output OFF
Bell:
Output for connection of audible sounder (siren). After the alarm
system actuation a continuous or pulse (fire) signal is generated.
OFF
ON
Alarm
Bell time
Bell
ARM/DISARM:
Output for connection of light indicator of the alarm
system status. When the alarm system is on a continuous signal is
generated.
OFF
ON
ARM/DISARM
Open
Close
Open
ARM
DISARM
Buzzer:
Output for connection of audio indicator. After the alarm system
activated a pulse signal is generated within Exit Delay time, and continuous
signal - within Entry Delay time or when the alarm system is disturbed.
When the alarm system is turned off, operates like keyboard buzzer.
OFF
ON
Open
Command - ARM
Exit Delay
Close
Entry Delay
Command - DISARM
Buzzer
Flash:
Output for connection of light indicator. When the alarm system
is on, a continuous signals generated, and if the alarm system is
disturbed - pulse signal. Signal is terminated by turning off the alarm
system.
OFF
ON
Flash
Open
Command - ARM
Close
Alarm
Open
Remote Control:
Output designed for connection of electrical devices
which will be controlled by SMS message or phone call a) control by SMS
message
Remote Control
b) control by phone call