GTM1 User manual V-2020-08-12
8 |
E N
1W
Programmable functions
Digital output (Max 3.3V)
Digital input (Max 3.3V)
Dallas 1-Wire bus. DS18b20, DS1990A
Aosong 1-Wire bus. Humidity Sensor AM2302, DHT22, AM2305, AM2306
Max available voltage
+3,3V
Max available current
10mA
+5V
Power output for external temperature, humidity sensors
Max available voltage
+5V
Max available current
100mA
1.6
Configuration methods
SMS text messages
In order to configure and control the device by SMS text message, send the text command to the PROGATE SIM card from one of the
listed administrator phone numbers.
Sera2 software
Sera2 software is intended for PROGATE configuration locally via USB port or remotely via 2G/3G/4G network. This software
simplifies system configuration process. Sera2 software is free, which you can download from our website: topkodas.lt
Remote connection
The system will NOT transmit any data to monitoring station while configuring the system remotely via 2G/3G/4G TLE network
connection. However, during the remote connection session, the data messages are queued up and will be transmitted to the
monitoring station after the configuration session is over.
Sera2 software provides remote system configuration ability using Topkodas Cloud server via GPRS.
1.7
System Access codes
Table 5 Default passwords and explanation
Password
Default
How to find and how to change
Explanation
SIM card PIN
1234
SERA2> System Options> General system options
It is automatically ignored if pin request in SIM card
is disabled
Installer
Password
000000
SERA2> System Options> General system options
This password allows you to enter programming
mode, where you can program all features,
options, and commands of the module.
SMS User
Password
123456
SERA2> System Options> General system options
This code allows you to utilize arming method, as
well as program user codes.
User password of
GSM operator
123456
SERA2> GSM Communications> GPRS/IP/TCP/UDP
User password of GSM operator network where
SIM card inserted in the module is operating.
App Key
123456
SERA2> GSM Communications> Sera Cloud Service
“APP Key” in module must be same as Remote
connection password via [cloud app] also in [SERA
remote] default: 123456
Installer code
(for SMS control
and configuration)
000000
INST000000˽090˽PSW
090= command code (Change of installer‘s code)
PSW = New Installer‘s password.
6-digit password used for system configuration,
control and request for information.
User code
(for SMS control
and configuration)
123456
INST000000˽091˽PSW
Change user‘s code
091= command code (Change user‘s code)
PSW = New user‘s password.
6-digit password used for system control and
request for information.
Master password
(Keybutton code)
1234 or
123456
(if selected
6 digit)
in user table
SERA2> Users/ Access control
6 or 4 digit code selected:
System Options> General system options> User
Access Code Format
Control functions for all newly associated keys will
be assigned according to MASTER key. For
example: If MASTER key will control Out1, all