GTM1 User manual V-2020-08-12
4 |
E N
1
General information about the module GTM1
1.1
Specifications
Parameters of built-in GSM module:
Quad-band (850/900/1800/1900 MHz)
Optional 3G ,4G LTE bands
Sending of SMS messages
Receiving of calls and dialing
Data download/upload via GPRS network
Outputs:
OUT1 (1A)
OUT2 (1A)
Programmable selectable outputs
IO1 (1A)
IO2 (1A)
IO3 (20mA)
1W, 10mA, Max voltage 3.3V!
Output state indication LED FN
All outputs can be controlled via short call
DIAL or via SMS message, mobile, web app.
This feature may be used for gate opening.
Output alarm parameters may be
programmed.
Programmable algorithms for outputs
operation: CTRL/SMS/DIAL, SIREN, BUZER,
ARM state, Zones OK, Light Flash, inverting,
pulse mode
Inputs:
IO1and IO2 programmable selectable input
IO1: 0-30V
IO2: 0-30V
IO3/D0 programmable selectable
IO3/D0: 0-30V analog input (zone or sensor)
IO3/D0: 0-20mA 4-20mA current loop sensor
2- wire Smoke Detector (Fire urrent loop)
IN1/D1: 0-30V
1W programmable selectable
Digital input (Max 3.3V!!!)
Dallas 1-wire bus
Aosong 1-wire bus
Wiegand keypad inputs: IO3/ D0 ir IN1/D1
SMS text for input alarm and restore
Available to control up to 32 sensors
Programmable enabling or disabling of inputs;
Burglary alarm zones. Input type
NC/NO/EOL/EOL+TAMPER 5.6K + 5.6K
Algorithm for zones operation: delay, interior,
instant, 24 hours, silent, fire
Response time;
Time of additional response;
Commutation of selected output
Digital input/ output 1W:
Programmable optional digital input or output
Max. Voltage 3.3V
Dallas 1-Wire Bus, DS18b20, DS1990A
Aosong 1-Wire bus Humidity Sensor AM2302
DHT22 AM2305 AM2306 AM2320 AM2321
Wiegand interface DATA0/ DATA1, RFID
reader, Keyboard.
The total length of the bus from 10 to 100m.
Module control:
ARM/DISARM of the security system via:
„Key switch” input level or pulse mode.
SMS message 800 users
short call DIAL 800 users
Maxim-Dallas iButton key (iButton DS1990A
–
64 Bit ID)) 800 users.
Wiegand keypad code or RFID keycard or key
fob 800 users
Mobile, web app
5V power source output for Dallas 1-Wire
Bus, DS18b20, DS1990A, Aosong 1-Wire bus
Humidity Sensor AM2302 DHT22 AM2305
AM2306 AM2320 AM2321
Voltage 5V
Current limit 100mA
AUX+ 10-30V/1A
Output state indication LED FN
Automatic periodical test:
Test sending in a form of SMS message.
Periodicity for communication control
messages (tests) from 1 to 99 nights and days
according to selected time. Or fixed periodical
interval 1-99999 minutes.
Power supply voltage:
DC 10-30V
AC 12-24V
Max. Allowed ripple voltage 100mV
Min 0.5A
Consumption current:
In standby mode less than 50 mA.
In dialing or SMS/GPRS sending mode
less than 300 mA.
Events Log:
Nonvolatile flash events log 2048 events
Environmental parameters:
Storage temperature range from -40 to
+85
o
C / -40 to 185
o
F
Operational temperature range from -30
to +75
o
C / from -22 to 167
o
F
Max relative humidity under +40
o
C / 104
o
F 95%
Package weight 90g
Module weight: 70g
Overall dimensions of the module:
73x62x26mm
1.2
Used definitions and terms
Term
Description
Alarm Log
Contains information about alarms that are currently active on the system or information about alarms that have been
raised and then resolved on the system. This log can be useful in analyzing problems and trends in the system.
Arming/Disarming
A process of enabling/disabling system's security.
Authorized user
It is a person whose mobile phone
’s number is entered in Progate module. Several authorized users with the same rights
may be entered into the module.
Backup battery
The secondary power source of the system. In case of a main power failure, the backup battery will take over.
Bell squawk
If enabled, the siren/bell indicates the completed system arming and disarming process (except the arming in STAY mode).
After the system is successfully armed, the siren/bell will emit 2 short beeps and 1 long beep after the system is disarmed.
By default, the parameter is disabled.
Bypass/Activate Zone
Zone bypassing allows the user to deactivate a violated zone and arm the system without restoring the zone. If a bypassed
zone is violated or restored during exit/entry delay, or when then system is armed, it will be ignored. The zone will remain
bypassed until the system is disarmed. Zones can only be bypassed and activated when the system is not armed.
Caller ID
Caller's identification
COM
Negative power supply terminal.