Sometimes it is useful security system’s details for automation purpose:
1.1. Automation/Sensors (Automation/Sensors/Analog Inputs) Programming in SERA2 Software
Step by step to start DS18b20 sensors:
3.
Connect 1-Wire sensors DS18b20 to D1 or D2, D3 according connection diagram.
4.
Digital input type D1,D2,D3 should be select in the System Options> Digital I/O Settings window. Set digital input definition D1, D2, D3 to Dallas
1-Wire Bus option
Figure 75System Option> General System Options window
8.
Write configuration by pressing “Write” icon
Figure 76Command line
9.
Power the module.
10. After module starts. Within few seconds, it will automatically scans and registers all connected 1-Wire sensors on the bus.
11. Read configuration
12.
Go to “Automation/ Sensors” window in the SERA2 software