background image

Band switch

d

escription for TS0S5

-01-

-02-

-03-

OCCUPANCY SENSOR SWITCH

Figure 2

Figure 3

TSOS5 /TWOS5

TSOS5

TSOS5

TWOS5

INSTALLATION INSTRUCTIONS

TWOS5

1.

Connect lead wires as WIRING DIAGRAM (see Figure 2): Black lead to

Line(Hot), Red lead to Load wire, White lead to Neutral wire, Green lead to

Ground.

2.

Gently position wires in wall box, attach sensor switch to the box.

3.

Mount device “TOP”up.

4.

Restore power at circuit breaker or fuse, wait

 one minute.

5.

Remove the small cover plate.  (Illustrated as Figure 3. )

6.

Locate the adjustment knobs on the control panel to perform test

 

and

adjustment.(Illustrated as Figure 3. )

7.

Replace the small cover plate after testing and adjustment.

8.

Attach the wallplate.

Time Delay knob

Default position: 15 Seconds (Test mode)

 

Adjustable: from 15 Seconds to

      Turn toward left to avoid false alert in smaller room and near 

 the door way or heat source.  

Ambient Light Level Knob

Default position: Daylight (100% at position 4)
Adjustable: Daylight to 30Lux (Counter clockwise) 

Note: to avoid wasting energy by turn-on the light under daylight.

  30 Minutes (clockwise)

Sensor Sensitivity Range Knob

Default position: Center at 65%

 

Figure 4

 

Adjustable: 30% (Position 1) to 100%  (Position 4)
Note: Turn toward right for greater room space.

Press

OFF

Figure 5

Press and release

AUTO

Figure 6

The passive infrared sensors work by detecting the difference between

 

heat emitted from the human body in motion and the background space.

 

The sensor switch can turn a load on and hold it as long as the sensor

 

detects occupancy. After no motion is detected for the set time delay, the 

load  turned  off  automatically.  The  sensor  switch  has  one  relay  (equal  to 
single pole switch), also includes Ambient Light Level Sensor.

AUTO

Mode

OFF

ON

Description

Circuit is permanently opened.

Position

Left

Center

Right

Load stays On always.

(switched off)

Occupancy Mode:
Automatic On when  occupancy is detected.
Automatic Off after the set time delay.

Push-button for TWOS5

As illustrated in Figure 5, the Load stays Off when the button is

 

 

pushed in and locked. (switched Off)

Figure 1

S

PECIFICATIONS

Switch Type...................................................................................Single Pole
Voltage................................................................................…..120VAC,60Hz
Fluorescent........................................…..........................................

..

..…500V

Motor  ................................................................................................…1/8Hp
Incandescent .........................................................................................500W
Time Delay  .....................................................….................15Sec to 30Mins
Light Level.............................................................................30 Lux--Daylight 
Operation Temperature.......................................................

.

....... 32 F--131 F 

D

ESCRIPTION

Coverage Area

The coverage

 range of the sensor switch is specified and illustrated in 

Figure  1.  Large  objects  and  some  transparent  barriers  like  glass 

windows will obstruct the sensor's view and prevent detection, causing 

the light to turn off even though someone is still in the detection area.

SAFETY  WARNING:

:

 

Read  and  understand  these  instructions

before  installation.  This  device  is  intended  for  installation  in 

accordance  with  the  National  Electrical  Code  and  local 

regulations. 

I

t  is  recommended  that  a  qualified  electrician 

perform  this  installation.  Make  sure  to  turn  off  the  circuit 

breaker or fuse(s) and test that the power is off before wiring 

the device.

 

Note: 

Please check 

the 

junction box for a neutral wire. This switch 

requires a neutral wire in the junction box for it to work properly.

 

W

iring Diagram

:

INSTALLATION

ADJUSTMENT

OPERATION