INSTALLATION INSTRUCTIONS
WARNING
Turn the
power off
at the circuit breaker before installing
the
timer
.
Read and understand these instructions before installing. This device is intended for installation
in accordance with the National Electric Code and local regulations. It is recommended that a
qualified electrician performs this installation. Make sure to turn off the circuit breaker or fuse(s)
and make sure power is off before wiring the device.
Use copper wire only.
Model:
TDHOS5
Dual Technology Humidity/PIR Motion Sensor
with Interchangeable Face Cover
Power..............................................................................................120VAC, 60Hz
Maximum fan load.......................................................................................3
A
mps
Incandescent maximum..........................................................................500
W
atts
Fluorescent maximum..................................................................................400VA
LED maximum.........................................................................................150
W
atts
..............................................................................*minimum light load of 10
W
atts
Light and Fan Time Delay......................................15s,
10
mins,
20
mins, 30 mins
Humidity range..................................................................................45%-80% RH
PIR coverage.............................................................................................600sq.ft
SPECIFICATIONS
As illustrated in Figure 1, The
TDHOS5
has a 180° detection range with a maximum distance
of 24’ detection in front of the sensor
and
12
' on the sides
. For maximum results, the sensor
must be properly installed between the height of 4’ to 5’ and away from obstructions such as
walls, furniture and transparent barriers like Low-E glass.
Figure 1
Max.
12
'
on the sides
Max.
24
'
from front
Installation
Height: 4' - 5'
Detection Range
COVERAGE
Figure 2
HOT
Black
Figure 3
1.
2.
How to change the color cover/ push button.
The switch comes with the top cover attached. Remove the wall plate
if
necessary
, then the cover may be changed as follow:
REMOVAL
Push down on the cover/ push
button to release, then pull away
from main body.
REATTACH
Align the latch pins to the unit,
push the cover/ button against
the main body, then slide up until
its locked into place
White
Neutral
White
Neutral
Red
Light
Brown
Fan
Green
Ground
Blue
Line 2
HOT
Black
Line 1
HOT
1.
Connect RED wire from
sensor
to the
LIGHT
wire
.
2. Connect BROWN wire from sensor to the FAN wire.
3.
Connect BLACK
AND
BLUE
wire from
sensor
to the HOT wire
.
4.
Connect
WHITE
wire from sensor
to the NEUTRAL wire
.
5.
Connect GREEN wire from sensor to the GROUND wire.
Single Pole
Wiring Diagram
OPERATING INSTRUCTIONS
The
TD
HOS
5
features
two
adjustable operation modes for customized control to suit the
specific ventilation
and
light
ing
needs of the room. These modes are as follows;
Occupancy with
Automatic Humidity
and Vacancy with Automatic Humidity
.
T
he
count-down
time
r
can
also
be adjusted to set the minimum "
ON
" time
for
the lights at
10
minutes,
20
minutes, or 30 minutes.
The fan will automatically turn on depend on the preset
humidity.
Once the Timer has been set, the
switch will automatically turn the lights off when
the
selected
time has expired.
However t
he fan will continue to operate if the sensor detects excess
humidity
.
The Fan will Automatically turn off after the humidity level is reached.
The sensor switch is
equipped with adjustable humidity
level
s
. The humidity
sensor
can be
adjusted
to low
, medium, or
high
level
.
When the PIR sensor detects movement the light button's green LED indicator will be flashing.
The fan's LED will turn red when the sensor detects excess humidity in a room; otherwise, it will
always stay lit in white.
Press and hold both light and fan buttons for 10 seconds, the green LED indicator will
come on solid. This setting allows users to switch back and forth between Occupancy
and Vacancy Mode.
•
Occupancy Mode
*
-
Auto On/Automatic Off Lights.
Auto On/Automatic Off Fan
base on preset humidity level.
o
Light:
Auto On, Auto Off.
The Light will automatically turn ON by PIR
sensor.
Auto OFF by Time Delay.
When manual button is used to turn ON, lights turn ON and then turn OFF by
preset time delay.
When manual button is used to turn OFF before the preset timer expire
d
, lights
turn off completely. After 3 minutes, PIR
preset timer
will resets and lights turn ON
if motion is detected.
o
Fan: Auto On, Auto Off.
The Fan will turn ON automatically when preset humidity
level is reached and automatically turn OFF when the humidity level drops below
the preset.
I
f the humidity level is higher than preset then the fan will continue to run after
a
5
min
utes
break.
When the manual button is used to turn ON,
t
he fan will turn ON for 30 minutes
and automatically
turn OFF
.
When the manual button is used to turn OFF
before the 30 minutes
, the fan will
turn OFF immediately and
the
humidity sensor
will
stop
detecting
. Only when the
manual button is used to turn ON again,
after
30
minutes
the humidity
sensor
will
be operational again
.
•
Vacancy Mode
-
Manual On/Automatic Off Lights.
Auto On
/Automatic Off Fan
base on preset humidity level
o
Light:
Manual
On, Auto Off.
Manual button is used to turn the Lights ON and
Lights turn OFF automatically after preset time delay.
If motion is detected (within
30 seconds) of the lights turning off, the Lights will remain ON
1
2
3