Topex MobiLink GSM Скачать руководство пользователя страница 1

 

 

 
 
 

 
 
 
 
 
 
 
 

MobiLink GSM i 

 
 
 

Interface to PBX trunk over GSM 900/ 1800MHz 

 
 
 

User’s MANUAL 

 
 
 
 
 
 

2009 

 

Содержание MobiLink GSM

Страница 1: ...MobiLink GSM i Interface to PBX trunk over GSM 900 1800MHz User s MANUAL 2009 ...

Страница 2: ...tributors to Italy France Spain Holland Bulgaria Greece Russia UK Republic of Moldova Turkey South Africa Nigeria etc In order to achieve effective and flawless manufacturing for its products TOPEX has carefully organized its Research and Development Department along with its production facility This allows TOPEX to have maximum control of all the processes involved in the complex operations relat...

Страница 3: ...pability to connect to an analog phone as well as to a PBX trunk 9 Programmable routing rules and CLIP table 9 Configuration of settings either by means of OAM program or from a DTMF phone 9 Wireless access to high speed Internet using 2G or 3G mobile networks GSM GPRS UMTS W CDMA 9 Excellent quality of a vocal signal 9 Fully compatibility with a wide range of PBX exchanges analog or digital 9 Pos...

Страница 4: ...be accomplish separately in purpose of natural resources preserving and to avoid the occurring negative effects about human health and environment The acquired product shall not be treated like household waste and will be given to a specialized company for recycling waste Please do not dispose your TOPEX product as unsorted waste household waste recycle it to protect the environment Separate the p...

Страница 5: ...pment on the PBX exchange 19 4 2 Connecting to a PBX trunk or a telephone 19 4 3 Achieving an incoming call 19 4 4 Achieving an outgoing call 20 5 ACHIEVING TEST CALLS 21 6 ENTERING THE PIN OR PUK CODE 21 7 CONFIGURING THE PC CONNECTION 23 7 1 The installation of USB driver 24 7 2 The installation of MobiLink GSM on USB port 25 7 3 Accessing the Topex modem 31 7 4 Setting up an Internet connection...

Страница 6: ...ed to your PBX you can assign one for each of mobile carriers so all incoming calls will be terminated as mobile to mobile calls inside the same network Also for any call made from a mobile phone in the field to the number assigned to SIM card that is used by a MobiLink GSMi connected to a PBX exchange you can call any local subscriber extension This will be again charged only as a mobile to mobil...

Страница 7: ... is a mobile gateway with two interfaces type FXS and GSM Power supply switching mains adapter Input 100 240V A C Output 12VD C 2A Max Power 25 W USB cable for connecting PC Flat telephone cable with RJ11 connector for connecting to PBX Antenna for mobile networks Multiband with magnetic base and 2 5 m long cable CD with Drivers Manuals OAM program Wall Mounting Kit Quick Install leaflet Warranty ...

Страница 8: ... use an ordinary GSM cell phone Required configurations PIN CODE REQUEST enter the default value of the equipment PIN CODE 1234 The default value of PIN CODE for equipment is 1234 if you want to change it use the OAM application If the check box Change PIN Code is enable MobiLink GSMi will generated a new PIN Code unknown for user which prevents using the SIM card on another terminal so we recomme...

Страница 9: ...ting the holder Handle with care the inserting or extracting the SIM card When inserting or change the SIM card MobiLink GSMimust be powered off For inserting the SIM card follow the next steps 1 Push the little yellow button for taking off the SIM carrier Note Because its small dimensions you can push the button using an object that has hard edge such as a screwdriver Note Because it s reduced di...

Страница 10: ...ODE REQUEST option enabled MobiLink GSM I will send to SIM the code that was stored If this code is different from the SIM code MobiLink GSMi switches into the mode of waiting for PIN code from the telephone interface Now you must either dial the code from a DTMF phone connected to the equipment or use the O A M software to enter the code If the PIN code was sent incorrectly to the SIM for three t...

Страница 11: ... located near the top of the plastic case to secure the MobiLink GSMi to the wall with indicators up and connector s panel downwards Perform the following steps Choose the mounting place such as it to be suited with a proper operation and installing and mounting requirements mark the position of a pair of holes on the wall spaced at 55 mm apart drill the holes in the wall insert the plastic dowels...

Страница 12: ...ication Company address origin country contact information PRODUCT FEATURES Model identification which allows the network operator to check the terminal as one of its approved models so no additional certification or approval is required Description and details of variant the type of mobile networks it works with number of mobile modules supply voltage CONFORMITY MARKS Conformity marks required by...

Страница 13: ...m left to right DC Power round JACK used for connecting the power supply adapter delivery in package USB USB B connector female used for connecting USB cable between MobiLink and a PC FXS Subscriber RJ11 connector used for connecting the telephone cable to an analog fixed phone or an analog trunk of the PBX FME connector used for connecting the GSM antenna is on the upper side of the MobiLink GSMi...

Страница 14: ...th a piece of flat telephone cable wired on both side with RJ11 connectors Depending upon the actual condition of installation you may need a second piece of cable or a greater length of telephone cable Connect the telephone cable with one of the end to the FxS connector and the other end to the PBX trunk of PBX exchange or an analogue phone Figure 4 Achieving FXS connection ...

Страница 15: ...ace of PBX exchange Improper installing the MobiLink GSMi equipment might lead to damage of MobiLink GSMi or PBX exchange If you join a local line of PBX exchange to the FxS connector of MobiLink GSMi then both equipments will generate current into the connection cable in this way MobiLink GSMi and PBX exchange may be damaged Connecting the USB data cable Connect the USB B connector male to USB co...

Страница 16: ...n one that is not magnetic The antenna will be threaded to RF connector available on MobiLink GSMi FME male type This RF connector is on the top side of equipment the antenna attachment will be done as is shown in the picture bellow Figure 6 Antenna attachment Caution Don t force the fastening of antenna screw the antenna manually by hand only Using a pairs of pliers may lead to damage of antenna ...

Страница 17: ...onnector Nipple male Note z The MobiLink GSMi unit and its antenna should be placed as far as possible from appliances or office equipment that is sensitive to radio interference microwave ovens copiers TV sets PC displays and multimedia systems For best results try to find a place of maximum signal reception for the Mobile antenna z In addition the antenna must NOT be located near heavy duty equi...

Страница 18: ...eristics can cause the damage of MobiLink GSMi interface Remember that the adapter is the disconnection device there is no POWER switch on MobiLink GSMi so the 230 VAC socket outlet must be installed near the equipment and must be easily accessible Before executing the operations from chapter 4 you must do the following operations The installation of USB driver launch the PL 2303 Driver Installer ...

Страница 19: ...n of the equipment it is recommended to make a temporary connection of MobiLink GSMi to a DTMF telephone that has the capacity to generate tones This way you can set up parameter by dialing special codes and into the handset you can hear the alarm tonalities by means which MobiLink GSMi informs you about its operating status or sends error warnings 4 3 Achieving an incoming call From mobile phone ...

Страница 20: ...obile network For further details of operation please see the OAM manual A voice link can be initiated in the moment when MobiLink GSMi generates dial tone by default continuously tone frequency 440 Hz But the Topex equipment allows you to u customize the dial and busy tones as well as the ringing sound The telephone sets the PBX extension or exchange trunk can send to MobiLink GSMi the call in DT...

Страница 21: ...ent wrong for three times in a row the SIM card will become blocked and request the PUK code to unlock To enter the codes you can use an analogue phone which is connected to the MobiLink GSMithrough the FxS interface The phone must allow you to dial digits in DMTF mode tones Also the FxS interface of MobiLink must be activated Alternatively if the MobiLink GSMi equipment is connected to a PBX trun...

Страница 22: ...ter a new PIN code If the PIN code was successfully inserted you should hear an mobile registration tone the GSM module signals that it has got the right PIN code and waits for registration over the GSM GPRS UMTS network If the PIN code was sent incorrectly then you should hear a warning tone and after that the PUK code request a fast beeping 5 6 Cautions a Interferences Some types of phone exchan...

Страница 23: ...powered up First you have to install the USB driver for the MobiLink GSMiequipment This interface can be used for data transfer and also for configuring the equipment with the OAM application There is an executable program that automatically installs the USB driver The executable name is PL 2303 Driver Installer exe Create a dial up connection for the mobile network The connection must specify the...

Страница 24: ...Install the MobiLink GSM equipment on the USB port COMx Verify the correct installation of USB port by view the COMx appearance in Device Manager Now you have finished the procedure of USB driver installation Note The same driver for USB is also needed for connecting the OAM application to the MobiLink GSMi equipment The OAM program is used for configuring and managing MobiLink FXS and also to sen...

Страница 25: ...IM REVA EN_2009 Page 25 51 USER S MANUAL 7 2 The installation of MobiLink GSM on USB port Enter Control Panel select Phone and Modem Options press on the Modems tab Select Add ...

Страница 26: ...IM REVA EN_2009 Page 26 51 USER S MANUAL Check Don t detect my modem I will select it from a list ...

Страница 27: ...IM REVA EN_2009 Page 27 51 USER S MANUAL Click Next to continue Select from Standard Modem Types a Standard 33600 bps Modem The wizard asks you for the port number where it will connect the modem ...

Страница 28: ...to Device Manager and press on the symbol at Port COM LPT Next Wait on please wait message The installation of the MobiLink GSMi mobile modem has successfully ended and to finish this wizard press Finish If the modem was successfully installed it should appear in the Phone and Modem Options window with the port number where it was installed ...

Страница 29: ... of the COM port where MobiLink GSMi is attached go to Control panel System Properties Hardware Device manager Ports Among the COM ports you will see also the one COM 10 in the example below where MobiLink is connected Of course the figures for your actual connections may be different ...

Страница 30: ...IM REVA EN_2009 Page 30 51 USER S MANUAL Set the communication parameters speed 115200 bps data bits 8 parity none stop bits 1 flow control None ...

Страница 31: ...e modem of MobiLink you must first send it the command string AT This can be done by means of an console emulator program such as HyperTerminal in Windows Click Start Programs Accessories Communications HyperTerminal Configure HyperTerminal for the respective COM ports and 8 N 1 communication parameters ...

Страница 32: ...ice call or SMS message But there is an alternate command which forces the modem to go into data mode no matter which state it is in This forced command is AT001 Note Remember that you have to memorize the name of the MobiLink GSMimodem and the port because you gone use this information when you will perform the Dial Up connection Also the same COM port number will be used for the connection to th...

Страница 33: ...e right one Next Insert the name of your Internet connection such as MobiLink FXS in our example Next In the Phone Number field insert 99 1 Next The mobile number used must have a specific format depending on your actual mobile phone operator In the User name field write internet In the Password field and respective Confirm password field write operator s name Next Finish ...

Страница 34: ...M GPRS UMTS modem must be configured with some initialization commands an additional AT command depending on the mobile phone carrier that you use From Control Panel select Phone and Modem options and select again the MobiLink modem in the current example Standard 33600 bps Modem on the COM 10 port respectively Click on Properties and then the Advanced tab ...

Страница 35: ...the DATA mode you will see that the middle LED orange color blinks three times to indicate data operation Some mobile data providers may require extra initialization commands such as the APN which includes the name of the respective carrier Thus the example below shos the initialization command sting for Vodafone Romania Now you have finished installing the Internet connection for the MobiLink equ...

Страница 36: ...n in the example below called Mlink and double click on it The Connect Mlink window shows up In the windows Connect Mobilnk you should check or enter in the corresponding fields the values adequate for your mobile data carrier the user name the password in the Dial field enter the mobile number to be dialed such as 777 or 99 1 Then click the Dial button at the bottom left The MobiLnk modem will di...

Страница 37: ...r screen which informs you that the equipment is connecting to Internet and the remote server verifies the username and password In the right corner of the status bar he network icon for Mlink connection begins to blink Now you can open a browser such as Internet Explorer and surf on the Internet ...

Страница 38: ...n from top downwards as shown in the drawing to the right Theese are marked with the following signs 1 A phone handset LED for FXS interface status red LED 2 Symbols for USB antenna signal level LED for wireless module status orange LED 3 A symbol of the power button LED for power status LED for FXS interface status red LED Off the line is not engaged ON the line is engaged LED for wireless module...

Страница 39: ...a dial tone the 440 HZ signal is continuous Warning tones If the SIM card has activated the request for PIN when the equipment starts it send the recorded PIN code If the sent code is not the same the equipment goes into a wait status and signals this with a sound Now you may enter the PIN code from the phone keyboard The connection of the phone is achieved through the FxS interface check if the F...

Страница 40: ...this option the user can initiate a call to the mobile network through the module If note enabled outgoing call won t be allowed over the GSM module CLIR when this feature is activated the ID number will not be send over the mobile network Change PIN code if this feature is activated the equipment generates a new PIN code known only by the user When MobiLink GSMi equipment starts after the old PIN...

Страница 41: ... programming when the programming is NOT correct upon error you will hear no tone This means that you must hang up the phone and try again to enter into the programming mode So for each of the parameters to be set up which are described below you must first dial the code because after each programming the MobiLink GSMi returns to the normal operating state it waits for digits to route calls not to...

Страница 42: ...polarity to be REVERSED during the call as compared to the other states of a call the default setting you dial 371 if you want the polarity to remain the same during the call as it was during the other states of a call you dial 370 Programming of power denial You can select to generate or not line voltage on the subscriber port while the GSM module is not registered with the mobile network If the ...

Страница 43: ...is 600 seconds Programming of timer preminder If enabled preminder minder audio signal will be generated at a few seconds before the end of each billing period you dial 61xyz where xyz is the value in seconds of the preminder timer the maximum value is the value of the minder minus one second example if the time quanta for billing is of 60 de seconds and you want to sound a warning 5 seconds befor...

Страница 44: ...o level towards the telephone interfaces you dial 83x where x may be from 1 minimum up to 4 maximum Programming of audio level towards the mobile network you dial 84x where x can also be from 1 minimum up to 4 maximum Programming of technology access You can establish what kind of mobile technology the GSM module will access you dial 85x where x 1 both 2G and 3G technologies are selected default x...

Страница 45: ... GSM GPRS UMTS data PS speed 384 Kbps Download and 128 Kbps Upload Analog FxS voice port Connector RJ 11 Data and programming port USB B version1 1 External antenna Multiband for GSM GPRS GSM GPRS UMTS Signaling LED s GSM FXO FXS Power supply 12 VDC 2A 230 VAC 0 3 A 50 Hz Dial tone 440Hz 5 programmable Line voltage 48Vcc 10 Line current 30 mA max Ring signal 25 Hz min 65 V Impedance 600 Dimensions...

Страница 46: ...s like Xerox monitors display electrical motors It must not be stored in environment with extreme temperatures When MobiLink GSMi unit is moved from cold environments to warm environments the equipment must not be start immediately It must be let half an hour to accommodate with the new temperatures else condensation may occur The mounting place will be selected according to conditions from instal...

Страница 47: ...ts This way any call towards a mobile telephone will be transmitted through the trunk that has installed the MobiLink GSMi equipment In this way you will pay only a mobile to mobile call avoiding interconnection costs Also any phone call initialized from a mobile phone in the field to a local subscriber of the PBX will be billed as a mobile to mobile call inside the same network and not like a mob...

Страница 48: ...B port for a high speed connection to the Internet without need of any kind of cable or DSL connection This application is addressed to SOHO clients or private persons that don t have a landline telephone connection In this way they can use the fixed phone to call any number from the mobile network GSM GPRS GSM GPRS UMTS As extra bonus they have a high speed connection to the Internet through the ...

Страница 49: ...er central switching office of the phone company A PBX is a private telephone switch It is connected to groups of lines junctions from one or more central offices and to all of the telephones at the location subscribers extensions served by the PBX Current exchanges are in fact PABX automated PBX which don t require a human operator to route the calls MobiLink GSMi was designed to work optimally t...

Страница 50: ...IM REVA EN_2009 Page 50 51 USER S MANUAL ...

Страница 51: ...d in a retrieval system or transmitted in any form or by any means electronic mechanical recording or otherwise without the prior written permission of the company TOPEX S A We certify hereby that the MobiLink GSMi unit is manufactured in concordance with the legal provisions concerning responsibility towards the quality of delivered products fulfills the quality parameters specified in its User s...

Отзывы: