7
Push-to-Open Installation — Gate in Closed position (Moving-Rod is retracted)
1.
Insert the M10 x 30 bolt through the center hole of the post bracket
and post pivot bracket as shown. Place a
¢
10 washer ,
¢
10 lock
washer and M10 nut on the bottom of the bolt and hand tighten.
2.
Attach the gate bracket and post bracket assembly to the opener by
inserting a clevis pin. Secure the clevis pins using the hairpin clips.
3.
Open the release hole plug on the top of the gate opener, insert the
release key, and turn the key 90° clockwise. This releases the motor and
allows the push-pull rod to be manually extended and retracted. To restore
normal operation, turn the key 90° counterclockwise.
4.
With the opener fully retracted and with the gate in the fully open
position (for Pull-to-Open installation) or fully closed position (for
Push-to-Open installation)
, place the gate opener with the Post Bracket
Assembly and Gate Bracket on the gate post and the gate. Position the
Post Bracket Assembly and Gate Bracket so that the gate opener is level.
While holding the gate opener in the level position, temporarily secure it with two C-clamps.