7
Preparation for Installation
There are two installation types for the gate opener,
Pull-to-Open
and
Push-to-Open.
In the
Push-to-Open
installation, gate opens out from the property. A
Push-To-Open
Bracket is required to be
used for each gate.
MT8012 gate opener can
NOT
be installed on the cylindrical gate post, and the width of the gate post should be
at least 120 mm.
Install the Opener on the Gate –
for Pull to Open
The position of Post Bracket is very important. The following illustrations and tables are required to determine
the proper mounting position for the Post Bracket. The tables show the maximum opening angle of the gate for
a given A and B. For example, if A is 18cm and B is 16cm, the maximum opening angle of the gate is 104°
Pull-to-Open Installation — Gate in Closed position (Moving-Rod is extended)
1.
Insert the M10 x 30 bolts through the center holes of the post bracket and Pull to Open Bracket as shown.
Place
¢
10 washers ,
¢
10 lock washers and M10 nuts on the bottom of the bolts and hand tighten.
2.
Attach the gate bracket and post bracket assembly to the opener by inserting a thread pin.
NOTE:
Ensure the gate does not open into public areas. One more person will help when installing.