Coming with UPS01 uninterrupted power supply, this series gate opener can be

powered by AC 100-240V electricity directly. It is allowed to use additional battery

(NOT incl.) and solar panel (optional) as BACK-UP or MAIN power source with this

UPS01.

Never connect the solar panel to the control board directly to charge the battery.

Periodic checks of the opener are required to ensure safe operation.

Save this manual.

AT6132 / AT12132

AT6132S / AT12132S

Содержание AT12132

Страница 1: ...uninterrupted power supply this series gate opener can be powered by AC 100 240V electricity directly It is allowed to use additional battery NOT incl and solar panel optional as BACK UP or MAIN powe...

Страница 2: ...n ca Amazon co uk Amazon de Other Please Specify Order Product Model Purchase Date Full Name Phone Email Address VERY IMPORTANT Street Address Apartment Unit City State Province Zip Code Country Regio...

Страница 3: ...verview 7 Preparation for Installation 8 Install the Opener on the Gate for Pull to Open 8 Install the Opener on the Gate for Push to Open 11 Mounting of the Control Box 14 Connection of the Power Sup...

Страница 4: ...destrian access shall be located such that persons will not come in contact with the moving vehicular gate 8 Pedestrians should never cross the pathway of a moving gate The gate opener is not acceptab...

Страница 5: ...lay on or around the gate and keep all controls out of their reach NOTE TOPENS Gate Operator can be used for driveway gates made by steel wood vinyl and shaped as panel tube and chain link While use o...

Страница 6: ...3 Parts List Extra Parts for AT6132S AT12132S...

Страница 7: ...C186 R WiFi Smartphone Remote Control with Camera TC186 WiFi Smartphone Remote Control with Camera TKP3 Wireless Keypad TC175P Wired Keypad TEW3 Vehicle Sensor Exit Wand HLR01 HomeLink Remote Control...

Страница 8: ...ers C Clamps small medium and large Level Hacksaw or Heavy Duty Bolt Cutters Phillips Screwdriver Technical Specifications Features Specifications AT6132 S AT12132 S Input 110 240V 50 60Hz Motor Volta...

Страница 9: ...auto close 3 120 seconds Built in max Motor running time MRT for multiple safety protection 40 seconds Reliable electromagnetism limit for easy adjustment Can be equipped with a wide range of accessor...

Страница 10: ...7 Installation Overview Important The second gate opener cable should be put into the PVC conduit not provided which is buried underground This protects the cable from lawn mowers and string trimmers...

Страница 11: ...ger size washer or metal plate should be used between the bolts and the wooden post to ensure the stability of the fastening hardware If the post is smaller than 6 diameter or square it should be made...

Страница 12: ...he opener fully retracted and with the gate in the fully open position for Pull to Open installation place the opener with the Post Bracket Assy and Gate Bracket on the gate post and the gate While ho...

Страница 13: ...t assy and the drilled holes in the gate post Fasten each bolt with one 10 washer one 10 lock washer and one 10 nut 9 Attach the gate brackets to each gate by inserting two M10 x 75 bolts through the...

Страница 14: ...on the Gate for Push to Open The position of Post Bracket is very important The following illustrations and tables are required to determine the proper mounting position for the Post Bracket The tabl...

Страница 15: ...erclockwise 4 With the opener fully retracted and with the gate in the fully closed position for Push to Open installation place the opener with the Post Bracket Assy and Gate Bracket on the gate post...

Страница 16: ...acket assy and the drilled holes in the gate post Fasten each bolt with one 10 washer one 10 lock washer and one 10 nut 9 Attach the gate brackets to each gate by inserting two M10 x 75 bolts through...

Страница 17: ...se 4 deck screws not provided to install the control box Even though the control box is waterproof designed for safety reason and a longer service life it is recommended to install the control box ins...

Страница 18: ...than 12 AH is required NOT INCLUDED 2 PCS 12VDC batteries can be connected in series to become 24VDC to power up the gate opener The following diagram will show you how to connect 2 PCS batteries in...

Страница 19: ...er source only use the solar panel to charge the batteries If the AC electricity is not available then you can choose the batteries as the power source and use the solar panel to charge the batteries...

Страница 20: ...electricity and back up batteries use the AC electricity and the solar panel to charge the batteries at the same time If you want to use the solar panel and the AC electricity to charge the batteries...

Страница 21: ...rminal 15 the black wire into MOTOR1 terminal 16 the blue wire into ULMT1 terminal 17 the green wire into COM terminal 18 and the yellow wire into DLMT1 terminal 19 2 Actuator 2 Slave gate close first...

Страница 22: ...erminals No matter the polarity The gate operator works alternately by pressing the button open stop close stop open 8 Electric Lock optional The electric lock should be wired to the LOCK terminal 13...

Страница 23: ...rchase additional remote controls the gate opener must be programmed to accept the new remote code If you lose one of any remote control please erase and reprogram all other remote controls to have a...

Страница 24: ...press OK button on keypad and CODE LED will flash for 3 seconds and then be OFF which indicates the keypad has been programmed successfully You can use the default password 888888 to operate the open...

Страница 25: ...desired open position press the remote control to stop the opener Use a screwdriver to loosen the screw of the limit B slightly slide the limit switch B inwards If the arm opens halfway and fails to...

Страница 26: ...ON Open interval is enabled OFF Open interval is disabled Factory default setting is ON NOTE Open interval time can be adjusted by the OPEN DELAY potentiometer DIP Switch 4 Enable disable close interv...

Страница 27: ...Turn the potentiometer clockwise to increase the stall force and turn it counter clockwise to decrease the stall force Maintenance Warning Disconnect power before servicing 1 Using a clean dry cloth...

Страница 28: ...ries have been connected to the UPS01 well 3 Battery is over discharge if you only use batteries with the UPS01 to power up the gate opener The voltage of the battery should above 22V to make the gate...

Страница 29: ...usted too small Turn the Potentiometer E to increase the force 3 Ensure the photo beam is not blocked when a photocell is used Both of the gates do not move when operating Flash quickly for 3 seconds...

Страница 30: ...check what will happen to the 2 arms If the faulty arm is still faulty then the arm itself is faulty If the failure changes to the other arm which worked normally before then the control board is fau...