User Manual

Содержание PulseQ AC Home

Страница 1: ...AC EV Charger User Manual ...

Страница 2: ......

Страница 3: ...DUCT OVERVIEW INFO Section 4 What s in the Box Section 5 Installation Section 6 Network Configuration Section 7 LED Indicators Section 8 Fault Handling Section 9 Warranty 3 4 7 9 13 14 24 28 29 30 IEC EV EVSE OBC KW A V Hz LCD LED 1 2 3 4 5 6 7 8 9 10 Human Machine Interface HMI 13 Central Management System manages EVSE and has the information for authorizing users for using its EVSE CMS 11 Open C...

Страница 4: ... vehicle connector Do not use this product if the flexible power cord or EV cable is frayed has broken insulation or has any other signs of damage Do not use this product if the enclosure or the EV connector is broken cracked open or shows any other indication of damage Indicate the ambient temperature rating 30 C to 55 C CAUTION and the following or equivalent To reduce the risk of fire connect t...

Страница 5: ...ching electrostatically sensitive components No access for unauthorized persons Use protective footwear Must wear a safety helmet Indicates important texts notes or tips 1 2 SAFETY NOTES Safety protection must be done when installing the EV Charger Installation must be carried out by personnel with professional qualification otherwise there is a risk of electric shock It shall be installed in the ...

Страница 6: ...r the charging cables is exposed If you find any please contact the supplier in time 1 2 4 Safety Precautions for Maintenance Personnel must always use protective footwear when maintenance work It is recommended that routine safety inspection visits to Charger be conducted at least once a week Do not put inflammable explosive or combustible materials chemicals combustible steam and other dangerous...

Страница 7: ...is Mode 3 and charging connection is the Case C Mode 3 a method for the connection of an EV to an AC EV supply equipment permanently connected to an AC supply network with a control pilot function that extends from the AC EV supply equipment to the EV Case C Connection of an EV to a supply network utilizing a cable and vehicle connector permanently attached to the EV charger Vehicle inlet Vehicle ...

Страница 8: ...PulseQ AC Home product meets IEC 62196 2 Type 2 PulseQ AC Home provides a Type 2 female plug with charging cable it only charging an EV with a Type 2 charging socket vehicle inlet Fig 2 3 1 Schematic diagram of Type 2 interface CP N PE L1 L3 L2 PP ...

Страница 9: ...dimensions of PulseQ AC Home charger are shown as Fig 3 1 1 The block diagram of PulseQ AC Home charger is shown as Fig 3 2 1 LED RCMU type A 6mADC RFID reader PT CT RS 485 WiFi or Bluetooth Charging interface Fig 3 1 1 The shape Dimensions of PulseQ AC Home 220mm 310mm 95mm Main CPU ...

Страница 10: ... That cord extension sets are not be used PULSEQ AC HOME Model Number Rated Voltage Rated Current Rated Power Safety Protection RCD Built in Charging Interface Mode 3 Remote APP controlled Local Plug and charge RFID Reader mode 4 LED lights Indicate 4 statuses include standby charging fault and network WiFi 2 4GHz 5GHz And support OCPP 1 6J Protocol Optional RS 485 with special communication proto...

Страница 11: ...over Black PC IP65 IK10 2000m 40 75 30 55 95 RH no water droplet condensation 0 5G no acute vibration and impaction Indoor or outdoor good ventilation no flammable explosive gases Mounting Net Weight Dimension Color Material IP Code IK Code Altitude Storage Temperature Operation Temperature Relative Humidity Vibration Installation Location 11 ...

Страница 12: ...z 32A 1 Phase 16A 3 Phase 32A 3 Phase 7kW 11kW 22kW IP 65 30 55 22 131 12 3 3 5 Nameplate This equipment should be reliably grounded before use Installation wiring and maintenance should be done by personnel with professional qualification Do not expose to flammable gas Failure to read user manual carefully before use may lead to improper operation 1 2 3 4 ...

Страница 13: ...ll mounting Accessories User Manual Quick User Guide Quality Certificate Wall Installation Template M6 63mm Expansion Bolt M5 40mm Expansion Bolt Charging Dock Installation Template IC card 1 1 1 1 1 1 1 4 4 1 2 a b c d e f g h i j k a g d e f j k c b h i 13 User Manual IC card ...

Страница 14: ...mal expansion and cold contraction Space requirement When the charger is fixed on the wall the minimum space requirements are shown in Fig 5 2 It is suggested that the charger should be installed in a place with good ventilation no direct sunlight and shelter from wind and rain In order to ensure good ventilation condition you should mount the charger vertically and leave enough space Fig 5 2 Mini...

Страница 15: ...nnection and measure the voltage Multimeter 1 Fastening bolt Wrench 3 Peeling cables Wire stripper 5 Drill fixing holes in the wall Electric Impact drill 2 Cut the cable Diagonal plier 4 Pressed cable terminal Crimping plier 6 Fastening screw Cross screwdriver 7 No Tools Name Schematic Picture Main Uses 15 ...

Страница 16: ...ere is WiFi signal available Refer to the Fig 5 4 2 to understand the dimensions of the wall bracket Please make sure the space on the wall is at least 5 62 5 98 143mm 152mm Fig 5 4 1 Fig 5 4 2 1 WARNING In areas with frequent thunderstorms add surge protection at the service panel for all circuits Ensure all power and ground connections especially those at the breaker and bus bar are clean and ti...

Страница 17: ...ith the installation template See Fig 5 4 3 Drill the mounting holes on the wall with a depth of at least 1 97 See Fig 5 4 4 Hammer the expansion sleeve into the corresponding hole See Fig 5 4 5 2 3 3 Fig 5 4 3 Fig 5 4 4 Fig 5 4 5 1 97 17 ...

Страница 18: ...Fix the bracket to the wall with the expansion screws See Fig 5 4 6 included in the package Attach the charger to the bracket See Fig 5 4 7 5 6 Fig 5 4 6 Fig 5 4 7 18 ...

Страница 19: ...See Fig 5 5 2 2 Fig 5 5 2 5 5 Hardwire Installation The hardwire installation needs to be done by electricians and please strictly follow the safety precautions Unscrew the six screws on the back cover with a Phillips screwdriver and remove the front cover See Fig 5 5 1 1 Fig 5 5 1 19 L3 L2 L1 N PE ...

Страница 20: ...flat blade screwdriver and fully insert the wire conductors into the connectors on the terminal block Tighten the screws and make sure each wire conductor is securely connected See Fig 5 5 4 4 Fig 5 5 4 20 L3 L2 L1 N PE L3 L2 L1 N PE 10 12mm Note For the model of PulseQ AC Home_7K_EU only connect the corresponding wire conductors to the L1 N PE connectors ...

Страница 21: ...Reinstall the front cover and tighten the gland 5 21 ...

Страница 22: ... 2 12 2 12 54mm 54mm Drill the mounting holes on the wall with a depth of at least 1 97 See Fig 5 6 2 Place the installation template on the wall and mark the mounting hole See Fig 5 6 1 5 6 Charging Dock Installation 54mm 54mm Fig 5 6 1 Fig 5 6 2 at least 1 97 ...

Страница 23: ...socket into the charing dock See Fig 5 6 3 Fix the charging dock on the wall with the expansion screw in the package See Fig 5 6 4 4 5 Please put the charging plug back to the Charging Dock after each charge Fig 5 6 3 Fig 5 6 4 ...

Страница 24: ...d install the app to your phone See Figure 6 1 1 Fig 6 1 1 Register an account with your email address and login See Figure 6 1 2 Open the app and tap the User Center select the charging station management See Figure 6 1 3 1 2 3 Section 6 Network Configuration Fig 6 1 2 Fig 6 1 3 6 1 Wi Fi Configuration ...

Страница 25: ...Tap the cross at the bottom right to add your charging station See Figure 6 1 4 Select the Wi Fi network See Figure 6 1 5 4 5 Fig 6 1 4 Fig 6 1 5 25 ...

Страница 26: ...Tap the TOPDON AC Home to connect the hotspot See Figure 6 1 6 Tap the Wi Fi Setting enter the Wi Fi name and password to set up the connection See Figure 6 1 7 6 7 Fig 6 1 6 Fig 6 1 7 26 ...

Страница 27: ...Once the above steps have been done tap the Confirm to complete the procedure See Figure 6 1 8 8 Fig 6 1 8 27 ...

Страница 28: ...ound fault status Twinkle Unconnected network OFF Fault status BLN control Exchange data with CMS via network ON Configure WiFi network status Twinkle Charging status 1 3 2 4 No Icon Indicator Color Indicator Status Connotation The LED indicators on the panel are used to indicate the status of the charger and the various combinations of indicators are described as below ...

Страница 29: ...off and restart the device Check whether the charging connector and its cable are damaged or wet Recover after pulling out the adapter Check whether the charging adapter and its cables are damaged or wet Check whether the charging connector is correctly connected Check whether the OBC is normal Check the set of output current Battery of EV is full Or the charging connector is not properly connecte...

Страница 30: ...ing cable from the date of purchase Warranty Period For the defects reported during the Warranty Period TOPDON will either repair or replace the defective part or product according to its technical support analysis and confirmation TOPDON shall not be liable for any incidental or consequential damages arising from the device s use misuse or mounting Some states do not allow limitation on how long ...