7
4.
Mount the brackets (B09) as shown in
Figure 5
. Install two (2) cable ties per bracket.
Figure 5: Bracket Mounting (Looking from the Rear)
5.
Install the base end of the position sensor with the cable facing the center of the sprayer in
the lowest hole of the bracket possible without making contact with the boom frame. Use
the mounting hardware as shown in
Figure 6
.
Figure 6: Mounting Hardware
6.
Install the linear sensor mounting bolt in the hole of the upper bracket that closest aligns
the end of the sleeve with the center of travel mark (black mark) on the sensor (
Figure 7
).
If the mark is missing, the distance from the end of the sleeve to the top of the base should
be 4” (100mm). The collar (
Figure 6
) clamps the sensor and prevents the rubber
grommet from sitting on the bolt threads. Tighten the mounting hardware.
Collar
Bolt
Nut
Nut
Содержание NORAC UC4.5