3-11
3 STANDARD MEASUREMENT MODE
3.3.2 Setting of the Instrument Height / Prism Height
Measure the coordinates by entering the instrument height / prism height, coordinates of unknown point
will be measured directly.
Confirm the angle measurement mode.
Operating procedure
Operation
Display
1
Press [F3](NEZ) key.
2
Press [F6](
↓
) key from the coordinate
measurement mode to get the function as in
page 2.
[F3]
[F6]
3
Press [F2](HT) key.
Previous data will be shown.
[F2]
4
Input instrument height, and press [ENT]
key.*1)
Inst. HT
[ENT]
5
Input prism height, and press [ENT] key.
The display returns to coordinate measuring
mode.
Prism HT
[ENT]
*1)To cancel the setting, press [F1](EXIT) key.
V : 90
°
10'20"
HR: 120
°
30'40"
SD HD NEZ 0SET HOLD P1
↓
N :
E : PSM 0.0
Z : PPM 0.0
(m) *F.R
MEAS MODE VH SD HD P1
↓
REC HT MEAN m/ft SET P2
↓
Inst. Ht : 1.230 m
R. Ht : 1.340 m
EXIT BS
N :
E : PSM 0.0
Z : PPM 0.0
(m) *F.R
REC HT MEAN m/ft SET P2
↓