![Topcon GPT-3000W Series Скачать руководство пользователя страница 32](http://html1.mh-extra.com/html/topcon/gpt-3000w-series/gpt-3000w-series_instruction-manual_1128632032.webp)
3-2
3 ANGLE MEASUREMENT
3.2
Switching Horizontal Angle Right/Left
Make sure the mode is Angle measurement.
3.3
Measuring from the Required Horizontal Angle
3.3.1 Setting by Holding the Angle
Make sure the mode is angle measurement.
Operating procedure
Operation
Display
1
Press the [F4](
↓
) key twice to get the function
on page 3.
[F4]
twice
2
Press the [F2](R/L) key.
The mode Horizontal angle Right (HR)
switches to (HL) mode.
[F2]
3
Measure as HL mode.
●
Every time pressing the [F2](R/L) key, HR/HL mode switches.
Operating procedure
Operation
Display
1
Set the required horizontal angle, using
Horizontal tangent screw
Display angle
2
Press the [F2](HOLD) key.
[F2]
3
Collimate the target.
Collimate
4
Press the [F3](YES) key to finish holding the
horizontal angle.*1)
The display turns back to normal angle
measurement mode.
[F3]
*1) To return to the previous mode, press the [F4](NO) key.
V : 90°10'20"
HR: 120°30'40"
0SET HOLD HSET P1
↓
TILT REP V% P2
↓
H-BZ R/L CMPS P3
↓
V : 90°10'20"
HL: 239°29'20"
H-BZ R/L CMPS P3
↓
V : 90°10'20"
HR: 130°40'20"
0SET HOLD HSET P1
↓
H ANGLE HOLD
HR: 130°40'20"
> SET ?
--- --- [YES][NO]
V : 90°10'20"
HR: 130°40'20"
0SET HOLD HSET P1
↓
Содержание GPT-3000W Series
Страница 1: ...GPT 3000W SERIES GPT 3002W GPT 3003W GPT 3005W GPT 3007W PULSE TOTAL STATION INSTRUCTION MANUAL...
Страница 2: ......
Страница 140: ...12 4 12 SETTING ATMOSPHERIC CORRECTION...
Страница 141: ...12 5 12 SETTING ATMOSPHERIC CORRECTION...
Страница 181: ...APPENDIX 5...
Страница 182: ...Bluetooth and the Bluetooth logos are trademarks owned by Bluetooth SIG Inc USA and licensed to Topcon Corporation...
Страница 183: ......