8-6
8 Scanning
8.2.3 Performing 3D Scanning
Example: SCAN DEGREE H:0.1°, SCAN DEGREE V:0.1°, SCAN NAME:hill
Operating procedure
Operation
Display
[Setting the scanning area]
1
Press the [F2](SCAN MENU) key to select the
scan menu.
2
Press the [F1](3D SCANNING) key.
[F2]
[F1]
3
Press the [F1](SCAN WIZARD) key.
[F1]
4
Aim to upper left by using Horizontal/Vertical jog.
5
Press the [ENT] key.
Aim to
upper left
[ENT]
6
Aim to lower right by using Horizontal/Vertical jog.
7
Press the [ENT] key.
The scanning area has been set.
Aim to
lower right
[ENT]
8
Press the [ENT] key.
If F4 "PRBE" is pressed, range of a center point of
scan area is measured and number of the range is
entered as DISTANCE automatically.
削除
[ENT]
[Setting the scanning density]
<Example: setting the SCAN DEGREE>
9
Press the [F1](UNIT) key.
[F1]
10
Press the [F1](UNIT) key.
[F1]
11
Select SCAN DEGREE H by pressing [F3](
↑
) or
[F4](
↓
) key.
12
Press the [F2](EDIT) key to input the scan degree.
[F3] or [F4]
[F2]
SELECT MENU
F1 STATION MENU
F2 SCAN MENU
P1/2
↓
SCAN MENU
F1 3D SCANNING
F2 TARGET SCANNING
P1/2
↓
3D SCANNING F1
F1 SCAN WIZARD
F2 MEASUREMENT
3D SCANNING
AREA SELECT
AIM TO LEFT-TOP
AND PRESS ENT KEY
3D SCANNING
AREA SELECT
AIM TO RIGHT-BTTM
AND PRESS ENT KEY
3D SCANNING
AREA SELECT COMPLETE
PRESS ENT KEY
→
DISTANCE [100
]
INTERVAL V [0.5 ]
INTERVAL H [0.5 ]
UNIT EDIT
↑
↓
3D SCANNING
POINT NUM H [100 ]
POINT NUM
V [100 ]
UNIT EDIT
↑
↓
3D SCANNING
→
SCAN DEGREE H[0.3]
SCAN DEGREE V[0.3]
UNIT EDIT
↑
↓
3D SCANNING
INPUT SCAN DEGREE H
[0.3
]
<-
Содержание GLS-1000 SERIES