2-9
2 PREPARATION FOR MEASUREMENT
PROCEDURE: Centering with the laser plummet
(
Option)
1
Set up the tripod and affix the instrument on the tripod
head.
“PROCEDURE: Centering with the optical plummet
eyepiece” steps 1 and 2
2
Press
{ON}
to power on
See Section 2.1 “Power Switch Key ON”.
•
The circular level is displayed on the screen.
3
Press {F1} to display observation screen.
4
Press
{
}
to display star key menu, and then press
{F1}
.
The laser plummet beam will be emitted from the bottom
of the instrument.
5
Use
{
}
/
{
}
to adjust the brightness of the laser.
6
Adjust the levelling foot screws to align the laser beam
with the center the survey point.
7
Press
{F1}
to turn the laser plummet off.
8
Continue to the levelling procedure.
See Section 2.5.2 “Levelling”.
•
Visibility of the laser spot may be affected when operating in direct sunlight. In this event, provide
shade for the survey point.