14
POWER SUPPLY
The ECO-ClimaTEC must be connected to a
Direct Current power supply (VDC). Use a
power supply, battery, generator, etc. with
sufficient power and adequate connections.
To select an appropriate power supply, see
the table below.
For more information about how to connect
the power supply see chapter:
Electrical
Instalation Instructions.
System configurations
TCT-units
4 xTCT-4PP-
15V10A
4 xTCT-4PP-
24V13A
2 xTCT-4PP-15V10A
2 xTCT-4PP-24V13A
Operating voltage (V)
12 VDC
12 VDC
24VDC
Maximum Current on
main Power
Connection (Amp)
145 Amp
120 Amp
70 Amp
Power supply (W)
12 x 145 =
min. 1740 W
12 x 120 =
min. 1440 W
24 x 70 =
min. 1680 W
LIQUID COUPLINGS
The ECO-ClimaTEC has two liquid loops. These loops are called the
interior and exterior loop. The interior loop is responsible for the
conditioning of the interior of the vehicle. The exterior loop takes
care of the expel of heat/cold into the exterior ambient.
There are used four couplings to connect the ECO-ClimaTEC with
the radiator/fan combinations of these loops.
These four front couplings are exchangeable with six types of
couplings.
Power supply