BWD
**
---63/80/100
ELECTRICAL TURRETS
INSTRUCTION FOR USE AND MAINTENANCE
Страница 1: ...BWD 63 80 100 ELECTRICAL TURRETS INSTRUCTION FOR USE AND MAINTENANCE ...
Страница 2: ... and damage to property and will also invalid any obligation for warranty 1 2 Before installing and commissioning the turret technician and the operator must have read carefully this instruction Manual 1 3 Commissioning adjustment and repair of the turret must be carried out by skilled and authorized personnel who must follow the instructions in this Manual for all necessary steps 1 4 YAXING decli...
Страница 3: ...tions Code Installing method centre H Order number When the turret indexing the disc needn t in axial motion Nr 6 Pos 6 63 standard Nr 8 Pos 8 F back 80 01 Other 1 other front 100 ITEM PARAMETER ITEM PARAMETER CENTER HIGH mm 63 80 100 Max Unbalancing torque Nm 10 12 20 POSITIONS N 6 8 Repeatability accuracy mm 0 005 INDEXING TIME 45 S 1 8 1 8 2 1 Dividing accuracy mm 0 03 INDEXING TIME 180 S 2 9 2...
Страница 4: ...he oil outlet 3 is the oil input Note Can be made according to your demands H A B C D E F G I J BWD 63 63 323 205 20 11 26 145 55 140 40 BWD 80 80 315 238 25 11 26 149 65 160 40 BWD 100 100 350 280 32 13 32 172 80 205 50 K L M N O P Q R S T BWD 63 190 134 165 185 50 30 30 30 G1 4 BWD 80 240 149 190 210 58 32 32 32 11 G3 8 BWD 100 305 188 220 250 66 40 30 30 G3 8 ...
Страница 5: ...quence Indexing signal motor rotating in CW NC received locating signal from turret stoped motor in CW and restarted motor in CCW clamping stoped motor detected the clamping signal and response signal working 7 Sequence diagram ...
Страница 6: ... T LOCKING CONTROL SWITCH T1 T2 T3 T4 T8 Hall code T is the time for the motor ccw and locking it is about 0 8 1 2s The gap time between motor cw stopping and ccw starting does not exceed 50ms The truth table of Hall coder position 1 2 3 4 5 6 7 8 T1 1 0 0 0 0 0 0 0 T2 0 1 0 0 0 0 0 0 T3 0 0 1 0 0 0 0 0 T4 0 0 0 1 0 0 0 0 T8 0 0 0 0 0 0 0 1 ...
Страница 7: ...20 8421 code T is the time for the motor ccw and locking it is about 0 8 1 2s The gap time between motor cw stopping and ccw starting does not exceed 50ms 21 22 23 TP The truth table of 8421 coder position 1 2 3 4 5 6 7 8 9 10 11 12 20 1 0 1 0 1 0 1 0 1 0 1 0 21 0 1 1 0 0 1 1 0 0 1 1 0 22 0 0 0 1 1 1 1 0 0 0 0 1 23 0 0 0 0 0 0 0 1 1 1 1 1 TP 1 1 1 1 1 1 1 1 1 1 1 1 ...
Страница 8: ...the coder and proximity switch The signaling device composed of Hall coder and optical coder 8 2 1 The connection of the Hall coder BRO RED ORA YEL GRE BLU VIO BLA BLU BLA BRO WHI 8 STATIONS TURRET LEA 1 2 3 4 5 6 7 8 9 10 11 12 FUN T1 T2 T3 T4 T5 T6 T7 T8 0V clamp VCC P r o x i m a t o CODER ...
Страница 9: ...te of the turret and the clamping proximate is the NC PNP switch and it is high lever effective and it s output current is 200mA 8 2 3 2 Hall coder It is composed of A 1104 BiCMOS Hall effect switches and lower lever effective LEA 1 2 3 4 5 6 7 8 9 10 11 12 FUN T1 T2 T3 T4 T5 T6 0V clamp VCC LEA 1 2 3 4 5 6 7 8 9 10 11 12 FUN 8 4 2 1 TP 0V clamp VCC CODER P r o x i m a t o CODER P r o x i m a t o ...
Страница 10: ... is 25 mA 8 2 4 NOTE 8 2 4 1 Do not with the signaling output terminal or proximate output terminal or proximate output terminal and electrode of the power short circuiting 8 2 4 2 It is must be close the power switch when you connecting the coder terminal and the proximate output terminal 8 2 4 3 Because the output device is used CMOS device so when you connected from turret to CNC system the gro...
Страница 11: ...able must be provided with fittings and gasket in order to penetration of water into the turret When the turret can not indexing at this frist must be cutoff the power switch and detected phase of the motor and then restarted when the turret indexing the turret must be agile and no abnormal sound 10 Use and maintenance 10 1 The back cap do not removed and every assembly do not changed 10 2 Indexin...
Страница 12: ... Hall unit or magnet is bad Unload cover checking signalling disc and supply adjust the position of the magnet and Hall unit or replace Hall unit 3 after having correctly perfomed the indexing cycle the disk stil unloked 1 the time of the CCW so short 2 bad contact 3 with the locking signal cut off the CCW rotating signal Adjusting the time of CCW checking wire pf the turret can not with the locki...
Страница 13: ... When you reassembling the turret it is must be make sure the fixing surface is clean and have not dust or other material 12 2 3 When you adjused coder at frist must be lock the turret at any position and set an approximate positioning by rotating the unit to get the corresponding position code or the signal passes from 1 to 0 and mark this new position and tighten the screws of the fixing pieces ...
Страница 14: ...10 14 Assembly drawing BWD 63 80 100 ...