NOTE
■
To obtain the best working and longest
working life of the generator, a new
generator should run at 50%
rated
load for the first 20 hours.
NOTE
■
Do not exceed the rated output of the
generator, as this will overload the generator
and trip the circuit breakers.
NOTE
■
Confirm all electrical appliances are in good
working condition before connecting them to
the generator. If an electrical appliance
becomes abnormal, sluggish, or stops
suddenly, shut off the engine immediately,
and disconnect the appliance .
6.1.3)
Turn on the AC breaker, and switch on the
electrical appliances.
6.2) Output
and
Overload Indicator
In normal operation, the output indicator light
(green) will stay on
.
If the generator is overloaded (over 6.5 kVA), or the
connected appliance
is
short
-
circuited, the output
indicator
light (green) will turn off
,
and the overload
indicator light (red) will turn on. The AC output will be
switched off, but engine will continue to run. If the
overload indicator light (red) is on, disconnect the
electrical appliances, and press the "RESET" to
recover the output. Once the overload indicator light
(red) is off and the output indicator light (green) is
on, reconnect the electrical appliances. Otherwise
stop the engine and check the generator.