2700-4001_22 IMA Manual
39
Last Revision: 12/14/2021
5.7.5 Control Techniques FM Motor Series - DE1
5.7.5.1 Motor Power Connector - DE1xxx
Manufacturer: Intercontec
Intercontec Part No.: BEDC 106 MR14 00 1216 000
Pin
Name
**Required
*Connect brake only when
present
1
Phase R
2
Phase S
3
GND**
4
Phase T
5
* BR+
6
* BR-
Keyed Center
5.7.5.2 Digital Incremental Connector - DE1 D1x
Manufacturer: Intercontec
Intercontec Part No.: AEDC 113 MR83 00 1216 000
Pin
Name
1
Temp -
2
Temp +
3
NC
4
Hall U
5
Hall U-
6
Hall V
7
Hall V-
8
Hall W
9
Hall W-
10
A+
11
I+
12
I-
13
A-
14
B+
15
B-
16
+5 Vdc
17
Com
Brake Information:
24 Vdc power is required to release the brake during operation. Ensure that pins 5 and 6 in
the power connector are used for the brake.
Thermal Device:
Motor equipped with thermal switch at 100C. Tolomatic recommends the use of the thermal
switch in order to protect the actuator in higher ambient temperatures.