Hour Meter
Figure 2-3. Hour Meter
Connection Plugs
The Hour Meter tracks hours of operation for
scheduled maintenance. See Figure 2-3.
NOTE
: The hour glass icon will flash when the
engine is running. This signifies the meter is
recording hours of operation.
The 120 Volt outlet is overload protected by a 20
Amp push-to-reset circuit breaker. See Figure 2-4.
Each receptacle will power 120 Volt AC, single
phase, 60 Hz electrical loads requiring up to 2400
watts (2.4 kW) or 20 Amps of current. Use only high
quality, wellinsulated, 3-wire grounded cord sets
rated for 125 Volts at 20 Amps (or greater).
Use a NEMA L14-30 plug with this receptacle
(rotate to lock/unlock). Connect a suitable 4-
wire grounded cord set to plug and desired
load. The cord set should be rated 250 Volts
AC at 30 Amps (or greater). See Figure 2-5.
Use this receptacle to operate 120 Volt AC, 60
Hz, single phase loads requiring up to 3240
watts (3.24 kW) of power at 27 Amps or 240
Volt AC, 60 Hz, single phase loads requiring
up to 6500 watts (6.5 kW) of power at 27
Amps. The outlet is protected by one 27 Amp
2-pole circuit breaker.
120 VAC, 20 Amp,Duplex
Receptacle
120/240 VAC, 30 Amp Receptacle
Figure 2-4. 120 VAC, 20 Amp, GFCI Duplex
Receptacle NEMA 5-20R
Figure 2-5. 120/240 VAC, 30 Amp Receptacle
NEMA L14-30R
0.0
Remove Contents from Carton
1. Open carton completely by cutting each
corner from top to bottom.
2. Remove and verify carton contents prior to
assembly. Carton contents should contain
the following:
6
Owner’s Manual for Petrol Generator