ToBattery LFP1208AP Скачать руководство пользователя страница 1

   
   

 

Thank you for purchasing the 

ToBattery 

LFP1208AP LiFePO4 Battery!  

  

   

Introduction 

  

 

  

LiFePO4 chemistry is an evolution in rechargeable battery technology. It is safer, non-toxic, higher 

performing, and longer lasting compared to lead-acid batteries. TOBATTERY provides the highest 
quality LiFePO4 battery from our ISO9001 certified production facility that guarantees maximum 
performance. Please carefully review the information below as they are vital to the safety and 
performance of the battery.   

 

  

Typical Applications 

  

 

  

 

---  Home security alarm, Electronics, Ham Radio, LED Lights, E-Bikes, E-Scooters, etc.

 

  

 

  

Contents 

  

 

  

  1 -   ToBattery LFP1208AP LiFePO4 Battery   
  1 -   User Manual   

 

  

Specifications 

(summary)

 

  

Dimensions (LxWxH) 

6x2.5x3.75 in 

Weight 

  

2.5 lbs.  

Battery nominal voltage and capacity 

  

12V, 8Ah   

Charging Voltage 

  

14.6V   

Charging Current 

  

<4A   

Open Circuit Voltage Range 

  

11-14VDC   

Maximum Continuous Discharge Current 

  

15A   

Maximum Peak Pulse Current  

  

20A (30 sec)   

Operating Temperature 

  

- 10°C to 60°C   

Protection: PCM/BMS  

 

Overcharge, overdischarge, overcurrent, 
balancing   

Terminal / connector type 

  

FastON 

For the full specification with update, please visit www.Tobattery.com   

 

  

 

Caution 

  

 

  

●  Do not disassemble.

 

  

●  Do not short circuit positive and negative terminals.

 

  

●  Recommend charge using LiFePO4 compatible chargers. 
●  Do not submerge in water, as the seal on the battery is not intended to be waterproof 
●  Do not throw in fire or otherwise dispose improperly. Recycle the battery at a facility that accepts 

lithium battery

 

  

 

 

  
 

 

Last Revised 02/11/2020 

  

Instructions for Use

 

  Charging   

 

  

1. 

Only use 

14.5V, LiFePO4 compatible

 chargers to charge the battery. The recommended 

charging current is 

1A-4A

2. 

It be charged through the charge & discharge terminal. 

3. 

Fully charge the battery 

before first use

.  This depends on the output of the charger but is 

typically between 3-10 hours.   

4. 

If your battery came with a Tobattery charger, the red LED light means the battery is under 
constant current (CC) charging and green LED means constant voltage (CV) charging. 
Always charge for at least 5 hours to ensure full capacity.   

5. 

LiFePO4 does not suffer “memory effect” so please keep the battery fully charged for daily 
use. Cell balancing only occurs when the battery is fully charged (top-end balancing).   

6. 

Do not

 charge the battery in temperatures below 0°C. This can cause damage to the cells.   

    

Discharging 

  

 

  

1. 

Make sure your load accepts 12V nominal voltage.   

2. 

Ensure the connection between the battery and the load can handle the current draw.   

Please consult references for the appropriate wire type.   

3. 

The maximum continuous discharge current is 

15

A. 

 

4. 

The battery outputs a steady voltage around 12.8V until very little capacity remain, 

do NOT

 

rely on voltage as an indicator of remaining capacity.   

   

Series and Parallel Connection   

 

  

We do not recommend using our LiFePO4 batteries in series or parallel connection if a single battery 

of equivalent size can be used instead. The PCM/BMS built into each battery is intended only for 
operation with a single battery and we do not guarantee the operability of multiple batteries in series 
or parallel configuration. Please take the information below into consideration if you must use a 
series or parallel configuration.   

   

Series:   

The battery design can be operated in series configuration. 

A maximum of 2 

batteries of the same specifications can be connected in series, and the total operating 
voltage must not exceed 24V.   

Parallel: 

Only connect batteries with equal state of charge in parallel. 

Also, measure the 

internal resistance of each battery and only use batteries with closely matched internal 
resistance. It is highly recommended that resistors be used to achieve equal internal 
resistance among multiple batteries. It is also highly recommended to add fuse(s) to the 
circuit for safety reasons.  

  Please keep in mind a series or parallel connection can fail with a number of consequences, from 
early cut off to possibly a fire. Always exercise caution and observe closely at all times.

 

The customer 

assumes all responsibility in the event of a series or parallel connection or connections.

 

  

   

Maintenance and Storage 

  

   

The battery requires no manual maintenance due to the included PCM/BMS. However, please 

follow the below guideline for best life cycle.   

1. 

Even though the LiFePO4 chemistry is relatively stable, protect the battery from shocks and 
drops to prevent internal short circuit.   

2. 

For long term storage, fully charge the battery and then discharge to 50% of the full capacity. 

Do NOT

 leave the battery unattended for more than 6 months.   

3. 

For the best life cycle, avoid using the battery in extreme temperatures and avoid highly 
variable pulsing loads.   

Отзывы: