![Toa VP-2241 Скачать руководство пользователя страница 109](http://html1.mh-extra.com/html/toa/vp-2241/vp-2241_instruction-manual_1122357109.webp)
Chapter 5: OPERATION
5. fAIlurE OuTPuT DETEcTION
5-37
5.2. Monitoring Log List
Possible causes of detected failures can be confirmed in the View log window.
for reading out the log file, refer to
.
Table below lists failure logs, possible causes, and their solutions.
[RM-200XF]
[RM-200X]
[EV-200]
log
Possible cause
Additional Information
Detail code
EV fault Occurrence
EV monitor
EV-200 failed
consult TOA dealer
unusable cf card installed
EV 1 kHz failure Occurrence No cf card installed.
Install a card.
EV-200's DIP switch setting not
performed
check for the EV-200's DIP switch
setting.
No cf card installed.
Install a correct card.
Install a card.
Solution
A component ID number is displayed here.
A component ID number is displayed here.
A component unit number is displayed here.
log
Possible cause
Solution
Detail code
Additional Information
rm/fm monitor rm microphone Occurrence
microphone element broken or coiled
cord disconnected
consult TOA dealer
rm microphone Switch
Occurrence
microphone key or Emergency key
broken
consult TOA dealer
rm low Power Supply
Voltage Occurrence
Power supply to rm dropped
Supply power directly from VX-2000DS
/3000DS.
use the connection cable with lower loss.
rm low Power Supply
rm to VX-200Xr lINK connectors
misconnected
check for the connector to be connected
to and the connection cable.
rm communication
Occurrence
rm to VX-200Xr lINK connectors
misconnected
check for the connector to be connected
to and the connection cable.
rm fault No. of rm-210
Occurrence
Actual No. of rm-210s and Pc-set No.
unmatched
match both Nos. by changing either. (If
the Pc setting is changed, download it.)
log
Possible cause
Solution
Detail code
Additional Information
rm/fm monitor rm microphone Occurrence
microphone element broken
consult TOA dealer
rm low Power Supply
Voltage Occurrence
Power supply to rm dropped
Supply power directly from VX-2000DS
/3000DS or an Ac adapter.
use the connection cable with lower loss.
rm line Occurrence
rm to VX-200Xr lINK connectors
misconnected
check for the connector to be connected
to and the connection cable.
rm communication
Occurrence
rm to VX-200Xr lINK connectors
misconnected
check for the connector to be connected
to and the connection cable.
rm fault No. of rm-210
Occurrence
Actual No. of rm-210s and Pc-set No.
unmatched
match both Nos. by changing either. (If
the Pc setting is changed, download it.)
Содержание VP-2241
Страница 12: ...Chapter 1 Note...
Страница 17: ...Chapter 2 ProduCt desCriPtioNs...
Страница 41: ...3 1 Chapter 3 system oPeratioN outliNe...
Страница 56: ...Chapter 4 FuNCtioNs...
Страница 73: ...Chapter 5 oPeratioN...
Страница 112: ...Chapter 6 FloWCHart From system setuP to oPeratioN...
Страница 116: ...Chapter 7 PC soFtWare oFFliNe settiNGs...
Страница 179: ...Chapter 8 iNstallatioN aNd settiNG ProCedures HardWare...
Страница 223: ...Chapter 9 CoNNeCtioNs...
Страница 266: ...Chapter 10 PC oNliNe CHeCKs aNd adJustmeNts...
Страница 282: ...Chapter 11 otHer PC soFtWare FuNCtioNs...
Страница 292: ...Chapter 12 aPPeNdiX...
Страница 298: ...Chapter 13 sPeCiFiCatioNs...
Страница 328: ...url http www toa jp 201409...