17
8.4. Connector Connection
The N-8000EX comes with mini-clamp connectors for line terminals and detachable terminal plugs for paging
output terminal, while the N-8010EX comes with mini-clamp connectors for line terminals.
Perform each connector connection as follows.
8.4.1. Mini-clamp connector connection
Connect the mini-clamp connector supplied with the N-8000EX to a cable using a commercially available tool
(pliers).
Step 1. Cut off two-cable ends in equal length, and insert them
securely to a cover section (transparent side) of the
mini-clamp connector.
Note
Insert the cable without stripping the cable jacket.
For cables, refer to p. 16, "Type of Cable."
Step 2. With a pair of pliers, lightly pinch the mini-clamp cover
and, after ensuring that the cable is securely inserted,
firmly squeeze on the cover.
Note
Squeeze on the mini-clamp cover until it is correctly locked.
Step 3. Insert the wired connector (plug) into the exchange's connector (socket) until it locks into place.
Cover (transparent side)
Cable
Mini-clamp connector
(accessory,
model 232D-02S1B-DA5
manufactured by DDK Ltd.)
N-8000EX/8010EX Rear panel