10
When the connected unit has an unbalanced input, make the connections as follows:
Connected unit
H
E
HOT (H)
Cold (C)
Earth (E)
IP-A1PC580R
IP-A1PC580S
Shield
Shield
From microphone or
other sound sources
To amplifier, etc.
9.2. IP-A1PC580S
10. CONNECTIONS
10.1. Connections to Line/Mic Input and Line Output Terminals
Use the supplied removable terminal plugs (6 pins) for connection. Use a 2-core shielded cable to
connect the audio device. Also, set the DIP switches according to the audio device to be connected.
For connection of the removable terminal plugs, see “Removable Terminal Plug Connections” on
Tip
Change the DIP switch settings while the power is off.
IP-A1PC580S
Mounting hole:
ø228.6 mm (ø9")
Machine screw
5 x 38 (accessory)
Wall board
From PoE
switching hub
Connect the IP speaker to the PoE Switching hub using
a LAN cable (straight UTP or STP cable, both rated at
Category 5 or greater and fitted with RJ45 connectors).
Compatible switching hubs:
Switching hubs conforming to PoE (IEEE802.3 af Class 3)
specifications.
[DIP switch settings]
Input device
DIP switch settings
Line level sound source
1: LINE
2: 0 dB [PAD]
3: OFF [PHANTOM]
(Default settings)
Dynamic microphone
1: MIC
2: 0 dB [PAD]
3: OFF [PHANTOM]
Electret condenser
microphone
1: MIC
2: –20 dB [PAD]
3: ON [PHANTOM]
Note
IP-A1PC580S is “Not for use in air handling spaces.”