TMG-LSN10/20/30 Part List

 

S/N 

PART 

PART DESCRIPTION 

QTYS 

NOTE 

HY001 

Front panel

 

HY002 

Back panel 

HY003 

Side panel (L) 

HY004 

Side panel (R) 

HY005 

Top panel 

HY006 

Bench 

HY007 

Floor panel 

HY008 

Bench heater 

HY009 

Handle 

Interior&Exterior 

10 

HY010 

Hinge 

11 

HY011 

Control panel 

12 

HY012 

Heat panel for Back panel 

13 

HY013 

Heat panel for side panel 

14 

HY014 

Heat panel for bench heater 

15 

HY015 

Speaker 

16 

HY016 

Glass door 

1565*540*6mm 

17 

HY017 

Control box 

18 

HY018 

Bluetooth 

19 

HY019 

Screws:

 For installing the bench & 

the roof panel

 

10 

M4*40 

20 

HY020 

Screws: For installing the handle 

M6*75 

Содержание TMG-LSN10

Страница 1: ...www tmgindustrial com P0 17 Toll Free 1 877 761 2819 13 5...

Страница 2: ...first time We recommend for you to keep this manual for future reference Benefits Superior Detoxification Removes Heavy Metals Fat stored Toxins Increased Cardiovascular Conditioning Stimulated Immun...

Страница 3: ...op panel 1 6 HY006 Bench 1 7 HY007 Floor panel 1 8 HY008 Bench heater 1 9 HY009 Handle 2 Interior Exterior 10 HY010 Hinge 2 11 HY011 Control panel 1 12 HY012 Heat panel for Back panel 2 13 HY013 Heat...

Страница 4: ...www tmgindustrial com P3 17 Toll Free 1 877 761 2819 1 1 1 1 1...

Страница 5: ...will cause damage to the interior and exterior of the sauna Assembly Instructions Assembly of the sauna requires at least 2 adults to complete Please read the instructions thoroughly before and during...

Страница 6: ...to the bottom panel by lining up the back panel on the bottom panel Please hold the back panel until one of the side panel had been installed Step 4 CONNECTING SIDE PANELS WITH BACK PANEL Align the si...

Страница 7: ...s with the vertical guides on side panel 1 The heater grill is facing outward toward the front of the sauna 2 Push the bench heater panel all the way down until it is touching the bottom panel and sec...

Страница 8: ...Step 7 INSTALLING THE BENCH 1 Install the bench by sliding it over the horizontal bench guides on the side panels 2 Push the bench all the way in until it can touch the back panel and is securely in...

Страница 9: ...st of the assembled panels When four corners are in place gently push down the roof panel from the outside corners until it is snugly fit over the rest of panels 2 Make sure the cables do not get pinc...

Страница 10: ...l Free 1 877 761 2819 Step 10 THE MAIN POWER CONNECTION ON THE ROOF PANEL 1 Connect all the wires for heaters 2 Connect the control panel wires 3 Check if all connections to the control box are secure...

Страница 11: ...el Operating Instructions INSTRUCTION 1 Press quickly to switch the sauna on to a stand by mode 2 Set the desired temperature using buttons 3 Set the time to desired length using buttons 4 Press quick...

Страница 12: ...w 1 Set up the desired session temperature and time using the control panel suggested 100 130 2 Allow approximately 10 15 minutes for the sauna to warm up before beginning a session 3 Recommend sauna...

Страница 13: ...your hair and wrap it with towel After the session is over rinse your hair thoroughly 6 Use at least 2 3 towels sit on one towel folded over several times for added cushioning Put another towel on the...

Страница 14: ...re as it cools off Once you feel comfortable enough take a warm or cool shower to rinse the sweat off your body completely Safety Read all health and safety instructions If in doubt as to the advisabi...

Страница 15: ...lood pressure and circulation 10 Never sleep inside the sauna while the unit is in full operation 11 DO NOT use any type of cleaning agents on the interior of the sauna 12 DO NOT stack or store any ob...

Страница 16: ...manufacturer may be hazardous 6 WATER OR MOISTURE DO NOT use your sauna near water e g near a bathtub in a wet basement or near a swimming pool etc 7 POWER CORD PROTECTION Power supply cord should be...

Страница 17: ...ntrol unit The fuse is burned out Check or replace the fuse 2 Function indicator light not on The corresponding indicator light is broken or burned out Repair or replace the control panel The wiring o...

Страница 18: ...ction fuse The socket is broken Replace it Problems with electrical control panel Check or replace the panel Disclaimers We shall not be liable for any loss due to use or misuse of the sauna or other...