background image

 

Chapter 4  Hardware Settings 

TI5VG+   User’s Manual 

15 

 

4.1  SW1(1-8): CPU Frequency Selector  

For Intel Pentium, IDT WinChip 2-3D / C6 

SW1 

CPU 

Clock 

AGP 

Clock 

Multiplier  CPU FREQ. 

 

  off  on  on  off off  off off  on  

66MHz 66MHz 

1.5x 

P54C-100 

  

  off  on  on  off on off  off  on 

66MHz 66MHz 

2x 

P54C-133 

 

off  on  on  off on on off on 

66MHz 66MHz 

2.5x 

P54C/P55C-16

 

off on  on  off off  on  off on 

66MHz 66MHz 

3x 

 

P54C/P55C-200 

WinChip 2-3D 

/ C6-200

 

 

 off  on  on  off off off off on 

66MHz 66MHz 

3.5x 

P55C-233 

 

 off  off on  off  off on off on 

75MHz 75MHz 

3x 

 

WinChip 2-3D 

/ C6-225 

 

  off  on on  off  on off  on on  

66MHz 66MHz 

4x 

 

WinChip 2-3D 

266 

 

off off off on off on on off 

100MHz 66MHz 

2.33x 

 

WinChip 2 

266 

 

off off off on on on off off 

100MHz 66MHz 

2.5x 

 

WinChip 2 

300 

 

Содержание TI5VG+

Страница 1: ...TI5VG Pentium MVP3 ATX Motherboard User s Manual Version 1 0F...

Страница 2: ......

Страница 3: ...elerated Graphics Port AGP Slot 12 Chapter 4 Hardware Settings 13 4 1 SW1 1 8 CPU Frequency Selector 15 4 2 JP1 DRAM Operating Frequency 20 4 3 SW2 1 4 CPU Voltage Selector 20 4 4 JP5 Clear CMOS Selec...

Страница 4: ...IOS Features Setup 41 6 5 Chipset Features Setup 44 6 6 Power Management Setup 47 6 7 PNP PCI Configuration 49 6 8 Load BIOS Defaults 52 6 9 Load Setup Defaults 52 6 10 Integrated Peripherals 53 6 11...

Страница 5: ...ption Hardware Settings Installation BIOS Configuration Checklist Please check that your package is complete and contains the items below If you discover damaged or missing items please contact your d...

Страница 6: ...he main features of this motherboard are listed as follows Main Processor Intel Pentium 100 133 166 200 Intel Pentium MMX P55C 166 200 233 Cyrix 6x86 6x86L P166 P200 Cyrix 6x86MX PR166 PR200 PR233 PR2...

Страница 7: ...ages and fan speed With the use of a system management utility the hardware status can be checked and warning message can be displayed when there is a problem Windows 95 Shut Down This allows the PC t...

Страница 8: ...Chapter 2 Specifications 4 TI5VG User s Manual This page is intentionally left blank...

Страница 9: ...Figure 1 which shows the locations of the key components The topics covered in this chapter are as follows 3 1 Processor and CPU Voltage 7 3 2 L2 Cache Memory 7 3 3 Main Memory 7 3 4 BIOS 9 3 5 Onboar...

Страница 10: ...Chapter 3 Hardware Description 6 TI5VG User s Manual Figure 1 Layout of the TI5VG Motherboard...

Страница 11: ...us Cache The P B Synchronous Cache boosts the system s performance 10 higher than regular Asynchronous Cache 3 3 Main Memory The TI5VG motherboard supports two 72 pin SIMMs and three 168 pin DIMMs Dua...

Страница 12: ...DIMM1 Total Memory 8MB 8MB 16MB 16MB 32MB 32MB 64MB 64MB 128MB 128MB 8MB 8MB 16MB 16MB 8MB 24MB 32MB 8MB 40MB 64MB 8MB 72MB 128MB 8MB 136MB 8MB 8MB 8MB 24MB 16MB 8MB 8MB 32MB 32MB 8MB 8MB 48MB 64MB 8...

Страница 13: ...176MB 32MB 32MB 32MB 96MB 64MB 32MB 32MB 128MB 128MB 32MB 32MB 192MB 64MB 64MB 128MB 128MB 64MB 192MB 64MB 64MB 8MB 136MB 128MB 64MB 8MB 200MB 64MB 64MB 16MB 144MB 128MB 64MB 16MB 208MB 64MB 64MB 32M...

Страница 14: ...an be as high as 17MB sec Using HDDs that support bus mastering the peak transfer rate can reach 22MB sec There are two IDE connectors primary IDE and secondary IDE With two devices per connector up t...

Страница 15: ...ime Clock NMI 080h 09Fh DMA Page Register 0A0h 0BFh Interrupt Controller 2 0C0h 0DFh DMA Controller 2 0F0h Clear Math Coprocessor Busy Signal 0F1h Reset Math Coprocessor 1F0h 1F7h IDE Interface 278 27...

Страница 16: ...IRQ0 System Timer Output IRQ1 Keyboard IRQ2 Interrupt Cascade IRQ3 Serial Port 2 IRQ4 Serial Port 1 IRQ5 Parallel Port 2 IRQ6 Floppy Disk Controller IRQ7 Parallel Port 1 IRQ8 Real Time Clock IRQ9 Soft...

Страница 17: ...ector 20 4 4 JP5 Clear CMOS Selection 22 In the case your motherboard TI5VG 100MHz has a processor supporting 100MHz CPU clock such as AMD K6 300 and your DIMM module is PC100 compliant the SDRAM cloc...

Страница 18: ...Chapter 4 Hardware Settings 14 TI5VG User s Manual Figure 2 Jumper Locations of the TI5VG...

Страница 19: ...66MHz 2x P54C 133 off on on off on on off on 66MHz 66MHz 2 5x P54C P55C 16 6 off on on off off on off on 66MHz 66MHz 3x P54C P55C 200 WinChip 2 3D C6 200 off on on off off off off on 66MHz 66MHz 3 5x...

Страница 20: ...200 166MHz off on on off off on off on 66MHz 66MHz 3x PR233 200MHz off on on off off off off on 66MHz 66MHz 3 5x PR266 233MHz off off on off on on off on 75MHz 75MHz 2 5x PR233 187 5MHz off on off off...

Страница 21: ...ff 100MHz 66MHz 3x MII 380 300MHz on off off on off off off off 95MHz 63MHz 3 5x MII 400 333MHz off off off on off off off off 100MHz 66MHz 3 5x MII 433 350MHz on off off on on off on off 95MHz 63MHz...

Страница 22: ...z 66MHz 2 5x PR166 K6 166 off on on off off on off on 66MHz 66MHz 3x K6 200 off on on off off off off on 66MHz 66MHz 3 5x K6 233 off on on off on off on on 66MHz 66MHz 4x K6 266 off on on off on on on...

Страница 23: ...Hz 66MHz 6x K6 2 400 off off off on on off on off 100MHz 66MHz 4x K6 2 400 K6 3 400 off off off on on on on off 100MHz 66MHz 4 5x K6 2 450 K6 3 450 on off off on off on on off 95MHz 63MHz 5x K6 2 475...

Страница 24: ...is 100MHz and the DIMM modules are PC 100 4 3 SW2 1 4 CPU Voltage Selector For Single Voltage CPU SW2 VIO VCORE CPU on on on on 3 5V 3 5V Intel P54C Cyrix 6x86 AMD K5 IDT WinChip C6 For Dual Voltage...

Страница 25: ...p 2 3D SW2 VIO VCORE CPU off off on on 3 3V 3 2V K6 233 0 35 on on off on 3 3V 3 1V off on off on 3 3V 3 0V on off off on 3 3V 2 9V K6 166 200 6x86MX off off off on 3 3V 2 8V WinChip 2 3D 0 35 P55C 6x...

Страница 26: ...off off off 3 3V 2 1V off off off off 3 3V 2 0V 4 4 JP5 Clear CMOS Selection Use JP5 a 3 pin header to clear the contents of the CMOS RAM Note that the ATX power connector should be disconnected from...

Страница 27: ...covered in this chapter 5 1 I O Connectors 25 5 2 J1 PS 2 Keyboard and PS 2 Mouse Connectors 25 5 3 J2 USB Connector 26 5 4 J3 J5 Serial Ports 26 5 5 J4 Parallel Port Connector 27 5 6 J6 ATX Power Su...

Страница 28: ...Chapter 5 Installation 24 TI5VG User s Manual Figure 3 Connector Location on the TI5VG...

Страница 29: ...o that of the connectors Refer to Figure 4 for the location and orientation of the connectors Figure 4 Orientation of the I O Connector 5 2 J1 PS 2 Keyboard and PS 2 Mouse Connectors Below are the pin...

Страница 30: ...Name 1 5 Vcc 2 6 USB 3 7 USB USB0 USB1 4 8 Ground 5 4 J3 J5 Serial Ports The onboard serial ports of the TI5VG J3 and J5 are two DB 9 external connectors The following table shows the pin out assignme...

Страница 31: ...D3 parallel data 3 5 18 Ground PD4 parallel data 4 6 19 Ground PD5 parallel data 5 7 20 Ground PD6 parallel data 6 8 21 Ground PD7 parallel data 7 9 22 Ground ACK acknowledge 10 23 Ground Busy 11 24 G...

Страница 32: ...2 RM LC Ground 3 4 No connect Ground 5 6 No connect Ground 7 8 Index Ground 9 10 Motor enable 0 Ground 11 12 Drive select 1 Ground 13 14 Drive select 0 Ground 15 16 Motor enable 1 Ground 17 18 Directi...

Страница 33: ...ound IRQ14 31 32 No connect Address 1 33 34 No connect Address 0 35 36 Address 2 Chip select 0 37 38 Chip select 1 Activity 39 40 Ground IDE2 Secondary IDE Connector Signal Name Pin Pin Signal Name Re...

Страница 34: ...ector that supports infrared wireless communication with IrDA devices Pin Signal Name 1 5V 2 No connect 3 Ir RX 4 Ground 5V IRRX IRTX N C GND 5 Ir TX 5 11 J10 Wake on LAN Connector J10is a 3 pin heade...

Страница 35: ...Reset Switch Turbo LED Connector ATX Power On Switch CPU Overheat LED Power LED and Keylock Speaker Speaker Pins 1 4 This connector provides an interface to a speaker for audio tone generation An 8 oh...

Страница 36: ...d for more than 4 seconds the system powers off When pressed for less than 4 seconds the system enters the Suspend Mode depending on BIOS pre settings Turbo LED Connector Pins 8 and 18 The Turbo LED w...

Страница 37: ...A Drive B Floppy 3 Mode Support Video Halt On 6 4 BIOS Features Setup 41 Virus Warning CPU Internal Cache External Cache Quick Power On Self Test Boot Sequence Swap Floppy Drive Boot Up Floppy Seek Bo...

Страница 38: ...g Temperature Temperature Fan Speed Voltage 6 6 Power Management Setup 47 Power Management PM Control by APM Video Off Method Modem Use IRQ Soft Off by PWRBTN HDD Power Down Doze Mode Suspend Mode PM...

Страница 39: ...OnChip Primary Secondary PCI IDE IDE Prefetch Mode IDE HDD Block Mode IDE Primary Secondary Master Slave PIO IDE Primary Secondary Master Slave UDMA Onboard FDD Controller Onboard Serial Parallel Port...

Страница 40: ...turn on the computer the Award BIOS is immediately activated Pressing the Del key immediately allows you to enter the Setup utility If you are a little bit late pressing the Del key POST Power On Sel...

Страница 41: ...ard Disk Type The section below the setup items of the Main Menu displays the control keys for this menu Another section at the bottom of the Main Menu just below the control keys section displays inf...

Страница 42: ...o 0 0 0 0 0 0 Auto Primary Slave None 0 0 0 0 0 0 Secondary Master None 0 0 0 0 0 0 Secondary Slave None 0 0 0 0 0 0 Drive A 1 44M 3 5in Base Memory 640K Drive B None Extended Memory 15360K Floppy 3 M...

Страница 43: ...ble For the Primary Master Slave as well as Secondary Master Slave you can select Auto under the TYPE and MODE fields This will enable auto detection of your IDE drives and CD ROM drive during POST Pr...

Страница 44: ...ve B Installed 3 mode drive at drive B Both Installed 3 mode drive at drive A and B Video This field selects the type of video display card installed in your system You can choose the following video...

Страница 45: ...Disabled Typematic Rate Setting Disabled Typematic Rate chars Sec 6 Typematic Delay Msec 250 Security Option Setup PCI VGA Palette Snoop Disabled OS Select For DRAM 64MB Non OS2 ESC Quit Select Item F...

Страница 46: ...nd Drive B becomes Drive A By default this field is set to Disabled Boot Up Floppy Seek When enabled the BIOS will seek whether or not the floppy drive installed has 40 or 80 tracks 360K type has 40 t...

Страница 47: ...r the User Password every time you boot up When you select Setup the system always boots up and prompts for the Supervisor Password only when the Setup utility is called up PCI VGA Palette Snoop Some...

Страница 48: ...ze 64M CPU PCI Clock Select Default ESC Quit Select Item Auto Detect DIMM PCI Clk Disabled F1 Help PU PD Modify Spread Spectrum Disabled F5 Old Values Shift F2 Color Cyrix M2 ADS delay Disabled F6 Loa...

Страница 49: ...ROM addressed at F0000H FFFFFH are cached provided that the cache controller is enabled Memory Hole at 15MB Addr In order to improve performance certain space in memory can be reserved for ISA cards...

Страница 50: ...When the system is turned on press the Delete key to enter BIOS Setup and configure the CPU speed Auto Detect DIMM PCI Clk When enabled the system automatically shuts off clocks of unused DIMM PCI sl...

Страница 51: ...ved Primary DMA master OFF ESC Quit Select Item Modem Ring Resume Disabled F1 Help PU PD Modify RTC Alarm Resume Disabled F5 Old Values Shift F2 Color F6 Load BIOS Defaults F7 Load Setup Defaults Powe...

Страница 52: ...using an ATX power supply The Instant Off mode allows powering off immediately upon pressing the power button In the Delay 4 Sec mode the system powers off when the power button is pressed for more th...

Страница 53: ...CI cards must be set to this value ROM PCI ISA BIOS PNP PCI Configuration AWARD SOFTWARE INC PNP OS Installed No CPU to PCI Write Buffer Enabled Resources Controlled by Manual PCI Dynamic Bursting Ena...

Страница 54: ...I I O Device Node This field enables or disables the ACPI I O Device Node The default setting is Disabled IRQ3 4 5 7 9 10 11 12 14 15 DMA0 1 3 5 6 7 assigned to These fields allow you to determine the...

Страница 55: ...rite When enabled writes to the AGP bus are executed with 1 wait states By default this field is set to Enabled AGP Master 1 WS Read When enabled reads to the AGP bus are executed with 1 wait states B...

Страница 56: ...or Load BIOS Defaults except Standard CMOS Setup To load BIOS defaults value to CMOS SRAM enter Y If not enter N 6 9 Load Setup Defaults This option allows you to load the default values to your syste...

Страница 57: ...1 Help PU PD Modify F5 Old Values Shift F2 Color F6 Load BIOS Defaults Onboard Parallel Port 378H IRQ7 F7 Load Setup Defaults OnChip Primary Secondary PCI IDE These fields allow you either to enable o...

Страница 58: ...bled Onboard FDD Controller This option allows you to select the onboard FDD port Onboard Serial Parallel Port These fields allow you to select the onboard serial and parallel ports and their addresse...

Страница 59: ...er setting a password the screen automatically returns to the main screen To disable a password just press the Enter key when you are prompted to enter the password A message will confirm the password...

Страница 60: ...ORMAL NOTE Some OSes like SCO UNIX must use N N N NORMAL for installation Up to four IDE drives can be detected with parameters for each appearing in sequence inside a box To accept the displayed entr...

Страница 61: ...AVING ESC Quit Select Item F10 Save Exit Setup Shift F2 Change Color Save Data to CMOS Exit Setup 6 15 Exit Without Saving Select this option to exit the Setup utility without saving the changes you h...

Страница 62: ...o the optional LANDesk Client Manager LDCM utility as well as the installation procedures The following items are covered in this chapter 7 1 Introduction 60 7 2 Installation 61 7 2 1 Installing the L...

Страница 63: ...ability to gather information about remote PCs as well as remotely controlling the PCs The remote access is based upon granted rights by the managed client LDCM provides the user with self help diagno...

Страница 64: ...g system Upon entering the Windows NT 4 0 or Windows 95 environment insert the CD Windows will autorun the installation program and show the following screen During Setup you will be asked to install...

Страница 65: ...stalling the Local Version of LDCM Double Click on LANDesk Client Manager in the initial screen and the following screen will appear Double click on the local version of LANDesk Client Manager When th...

Страница 66: ...where Setup will install LANDesk Client Manager Click Browse if you want to change the directory suggested Otherwise click Next to start installing LDCM When Setup is finished changes will have been...

Страница 67: ...lient Manager in the initial screen select the administrator version of the LDCM and the Welcome screen below will appear Click on Next to continue The screen below allows you to install the documenta...

Страница 68: ...Chapter 7 LANDesk User s Guide 64 TI5VG User s Manual After LANDesk Client Manager Setup is complete restart your computer to be able to use the LANDesk Client Manager...

Отзывы: