FLOW RATES
Do not exceed the maximum flow rates as this will considerably reduce the
efficiency of the unit.
V
2
ecton 200:
For aquariums up to 200 litres/50 imp gal/60 US gal
Maximum flow/hr: 680 litres/150 imp gal/180 US gal
V
2
ecton 300:
For aquariums up to 300 litres/65 imp gal/80 US gal
Maximum flow/hr: 960 litres/215 imp gal/255 US gal
V
2
ecton 400:
For aquariums up to 400 litres/90 imp gal/110 US gal
Maximum flow/hr: 1300 litres/290 imp gal/350 US gal
V
2
ecton 600:
For aquariums up to 600 litres/130 imp gal/160 US gal
Maximum flow/hr: 1900 litres/420 imp gal/505 US gal
Always use the largest diameter hose possible, this will ensure that you get the
maximum performance from your water pump.
CONNECTION TO THE ELECTRICAL SUPPLY
Power must be supplied through a Residual Current Device (RCD) with a rated
residual operating current not exceeding 30 mA.
This unit is supplied fitted with a moulded plug:-
For the United Kingdom: Fitted with a 3 Amp BS1363A plug
For Mainland Europe:
Fitted with a Schuko 10/16 Amp two pole and earth plug
For the USA:
Fitted with a 15 Amp two pole and earth plug
LAMP LIFE
The UV lamp fitted in this unit has a usable of life of 8000 hours (one year).
At 8000 hours the lamp will still be glowing brightly but the emission of
germicidal UVC will have deteriorated to approximately 85% efficiency.
For the majority of home aquarium applications the lamp should be changed
once a year (8000 hours).
For more critical applications the lamp should be changed at 4000 hours.
ROUTINE MAINTENANCE
The UV lamp should be changed at intervals of either 4000 hours or 8000
hours dependent on application. At each lamp change the quartz sleeve should
be removed and cleaned.
WATER DISPLACEMENT GASKET
A soft black circular rubber gasket is fitted to the right hand side of the white
plastic body and is fitted to protect the lamp holder assembly from any accidental
water spillage or splashing.
Each time the cover is removed from the base this gasket must be correctly
located on re-assembly.
When replacing the cover, and before screwing it to the base, make sure that
the gasket is fitted onto the right hand end of the white plastic body and located
between the white plastic body and the white plastic compression fitting. It will
be held (loosely) in place by this compression fitting. When correctly fitted the
gasket must lean towards the right, away from the outlet port.
When the cover is replaced on the unit this gasket will be visible through the
cover and should be tilting away from the outlet port and towards the lamp
end and lamp holder.
When correctly fitted this gasket will protect the lamp end assembly from any
possible water splash.
3
Correctly
positioned
water
displacement
gasket