Страница 1: ...FOR ADVANCED AQUARISTS BY TMC FOR ADVANCED AQUARISTS B BY TMC TMC...

Страница 2: ......

Страница 3: ...it is malfunctioning or if it has been dropped or damaged in any way This unit is designed to be used indoors and is not suitable for any outdoor applications Ensure the EASI Dose Plus dosing system...

Страница 4: ...or accurately measuring 10ml TECHNICAL SPECIFICATION Power Consumption 4W Max Flow 60ml minute Motor Speed 3800rpm Accuracy 5 PARTS LIST 1 LCD display 2 Dosing pump head 3 Silicone hosing 3m 4 Inlet l...

Страница 5: ...3 1 2 10 5 4 4 4 4 4 4 4 4 4 4 3 6 7 7 7 8 8 8 9 7 6 6 6 3 3 5 5 5 5 5 5 5 5 5 2 2 2 2 2 2 2 1 1 1112 13 10 11 12 13 10 11 12 13 14...

Страница 6: ...engths of hosing are long enough to connect your liquid storage containers to the inlet s 4 on the dosing pump head s 1 and to connect the outlet s 5 to your desired dosing location without any kinks...

Страница 7: ...olled from the Master system EASI Dose Plus 1 2 or 3 giving you up to 8 additional pumps If you wish to expand your EASI Dose Plus Master system simply connect an EASI Dose Plus Slave sold separately...

Страница 8: ...doser to running mode the on the clock will flash whilst in running mode but not whilst in setting mode B Dose t Button This button will allow you change the dose quantity in ml and also scroll to the...

Страница 9: ...set when to dose Each pump can deliver your determined dosing volume up to 24 times per day on each hour should you require it Each pump will start approximately 3 minutes after the previous one in o...

Страница 10: ...8 Example Settings Pump No 1 DosingVolume 10ml Dosing Times 08 00 12 00 16 00 Pump No 2 DosingVolume 20ml Dosing Times 04 00 08 00 12 00 16 00 20 00 Pump No 3 DosingVolume 100ml Dosing Times 12 00...

Страница 11: ...anually dose additives as and when required CALIBRATINGYOUR EASI DOSE MASTER ALL MODELS The calibration process is based on calibrating to a 10ml dosing volume The calibration process should be carrie...

Страница 12: ...eved IFTHE DOSEDVOLUME IS MORETHAN 10ML 12 If the dosed volume is more than 10ml press the Dose button 2 to reduce the DoseVol ea from 100 to 99 13 Empty the liquid from the measuring vessel place the...

Страница 13: ...consumable items are not covered under the 12 month guarantee please see back page for details on all available accessories and spares REPLACINGTHE DOSING PUMP HEAD 1 To replace the dosing pump head...

Страница 14: ...ect the rollers the silicone hosing and the inside of the dosing pump head for wear Replace any parts that are worn 3 Wrap the silicone tubing around the rolling wheel and re insert into the dosing pu...

Страница 15: ...osing on the hour Solution Each pump will run in order with approximately a 3 minute gap between doses This ensures your liquids will mix correctly and will help to stop precipitation of balling salts...

Страница 16: ...5L 9535 EASI Dose Plus 3 EASI Dose Plus Slave Tropical Marine Centre Solesbridge Lane Chorleywood Hertfordshire WD3 5SX UK Technical Information Lines Tel 44 0 1923 284151 Fax 44 0 1923 285840 Open b...