background image

 

 

 

 

- 23 - 

 

 
Limited Warranty 
 

ProPlex Data Distribution Devices are warranted by TMB against defective materials or workmanship for a 
period of two (2) years from the date of original sale by TMB.  
 
TMB’s warranty shall be restricted to the repair or replacement of any part that proves to be defective and for 
which a claim is submitted to TMB before the expiration of the applicable warranty periods.  
 
This Limited Warranty is void if the defects of the Product are the result of:  

 

Opening the casing, repair, or adjustment by anyone other than TMB or persons specifically authorized 
by TMB  

 

Accident, physical abuse, mishandling, or misapplication of the product.  

 

Damage due to lightning, earthquake, flood, terrorism, war, or act of God.  

 
TMB will not assume responsibility for any labor expended, or materials used, to replace and/or repair the 
Product without TMB’s prior written authorization. Any repair of the Product in the field, and any associated 
labor charges, must be authorized in advance by TMB. Freight costs on warranty repairs are split 50/50: 
Customer pays to ship defective product to TMB; TMB pays to ship repaired product, ground freight, back to 
Customer.  
 
This warranty does not cover consequential damages or costs of any kind.  
 
A Return Merchandise Authorization (RMA) Number must be obtained from TMB prior to return of any 
defective merchandise for warranty or non-warranty repair. For all repairs please contact TMB Tech Support 
Repair using the contact information below or email [email protected].  
 
US 

UK 

527 Park Ave. 

21 Armstrong Way 

San Fernando, CA 91340  

Southall, UB2 4SD England 

Tel: +1 818.899.8818  

Tel: +44 (0)20.8574.9700 

Fax: +1 818.899.8813  

Fax: +44 (0)20.8574.9701 

[email protected]  

[email protected] 

www.tmb.com  

www.tmb.com 

 

Return Procedure 

 

Please send returned merchandise prepaid and in the original packing.  Freight call tags will not be issued for 
shipping the product to TMB, but TMB will pay the freight for return to the customer.  Clearly label package 
with a Return Merchandise Authorization Number (RMA #).  Products returned without an RMA # will delay 
service.  Please contact TMB and request an RMA # prior to shipping the unit.  Be prepared to provide the 
model number, serial number, and a brief description of the cause for the return.  Be sure to properly pack 
the unit; any shipping damage resulting from inadequate packaging is the customer’s responsibility. TMB 
reserves the right to use its own discretion to repair or replace product(s).  Proper UPS packing or double-
boxing will better ensure product integrity when shipped. 
 

Note:  If you are given an RMA #, please include the following information on a piece of paper inside 
the box: 

1) Your name 
2) Your address 
3) Your phone number 
4) The RMA # 
5) A brief description of the symptoms 

 

 
 

 
 

Содержание ProPlex IQ Two 1616

Страница 1: ...1 ProPlex IQ Two 1616 USER MANUAL TMB 24 7 Technical Support US Canada 1 818 794 1286 Toll Free 1 877 862 3833 877 TMB DUDE UK 44 0 20 8574 9739 Toll Free 0800 652 5418 e mail techsupport tmb com...

Страница 2: ...ses Input or output on any connector Full RDM functionality Merge Art Net or Streaming ACN from multiple sources RDM Manager software available for system setup and feedback Web interface manage large...

Страница 3: ...e node the console with the higher channel 512 value will have control over the universe Off On On source loss This setting determines what will happen on source loss Hold output On DMX source loss ho...

Страница 4: ...deleting the configuration settings Confirm Back User cfg 2 node name User configuration profile 2 Load Button for loading the configuration settings Confirm Back Record Button for recording the conf...

Страница 5: ...e main status screen is displayed showing all of the important information about the IQ Two 1616 node Top of Touchscreen Configuration Device ID ProPlex IQ Two 1616 DMX refresh 40Hz see DMX OUT REFRES...

Страница 6: ...put and there is no active DMX signal DMX activity LED is BLUE full power The port is configured as DMX input and DMX signal is active DMX activity LED is BLUE dim The port is configured as DMX input...

Страница 7: ...iguration Menu By pressing the Configuration button a new configuration sub menu will pop up There are six pages 1 Node setup 2 Protocol setup 3 Protocol setup 4 IP setup 5 Configuration profiles 6 De...

Страница 8: ...ault with your desired name By pressing this button a new window will pop up Using this keyboard you can exchange the name to your desired name By pressing the lower left shift Level 2 Select key butt...

Страница 9: ...counting system Screen lock time By pressing the Screen lock time section a new window will pop up Here you can set the screen lock time This setting will change the time after which the ProPlex IQ T...

Страница 10: ...nd efficient network and DMX universe configuration Streaming ACN sACN is a popular protocol to control large numbers of universes and RGB DMX devices Both Art Net and Streaming ACN are Ethernet based...

Страница 11: ...urce loss button a new window will pop up When the Hold values setting is chosen after the source DMX is lost the IQ Two 416 holds the last DMX values it has received and continues to output these val...

Страница 12: ...resend time By pressing the Art Net idle resend time section a new window will pop up This setting determines the time Art Net will refresh the signal after idling You can select from 0 5s 1s 2s or 4...

Страница 13: ...e IQ Two 416 outputs DMX over 5 pin XLR connectors Some DMX devices work better using different refresh rate settings In the cases of high speed devices like LED walls and displays using the Adaptive...

Страница 14: ...software will search for all masks not only for a specified one In the case the Easy IP setting is turned ON you will not be able to change the subnet mask Easy IP is very useful for most networking s...

Страница 15: ...IQ Node Two save slots are available Choose which configuration you want to save User cfg 1 or User cfg 2 For example name the User config 1 as Show 1 And User config 2 as Amazing show Now press Recor...

Страница 16: ...les screen you can either load or delete the configuration you saved If you will press the Load Record or Delete button a confirmation window will appear where you will need to press OK to confirm you...

Страница 17: ...will reset all protocol related settings sACN Art Net settings Touch screen calibration will open touch screen calibration menu Factory defaults will reset all settings and restart the system After pr...

Страница 18: ...ng port 2 settings by pressing this button you will be switched to port 1 By pressing the button marked with green home button you will return to the main menu This is an example of port A DMX value s...

Страница 19: ...n for example if currently you are editing port 1 by pressing the up button you will be switched to port 2 By pressing the down arrow you will switch to the previous port for example if currently you...

Страница 20: ...ation status monitoring and management of these devices in such a way that does not disturb the normal operation of standard DMX512 devices that do not recognize the RDM protocol source www rdmprotoco...

Страница 21: ...When the node is turning on press anywhere on the ProPlex 1616 illustration 2 Open the device defaults settings where touchscreen calibration reset setting can be seen Now you have to press the red do...

Страница 22: ...s and makes managing multiple nodes on a network extremely easy The Software also includes a RDM management suite for devices connected the IQ nodes or via a ProPlex RDMigo Cable ProPlex IQ Ethernet t...

Страница 23: ...must be obtained from TMB prior to return of any defective merchandise for warranty or non warranty repair For all repairs please contact TMB Tech Support Repair using the contact information below o...

Страница 24: ...UM AMBIENT TEMPERATURE 20 C COOLING CONVECTION OPERATING HUMIDITY 10 80 CONTROL PROGRAMMING ETHERNET PORTS 1 ART NET SACN UNIVERSES 16 MAX DMX PORTS 16 DMX CONNECTORS NEUTRIK XLR 5 FEMALE DMX PORT ISO...

Отзывы: