background image

2.    Observe These Precautions to Ensure Safety 

072-65284M-02 (SonicMan SN1)    24 Feb 2005

 

2.2 

Battery Pack Precautions 

 
 

Do not use any charger other than 
the charger provided with the unit.

 

Failure to observe this precaution 
could result in leakage of the battery 
fluid, excessive heat generation, 
rupture or ignition. 

 

PROHIBITED 

Do not disassemble, modify, 
solder, etc.

 Failure to observe this 

precaution could result in leakage of 
the battery fluid, excessive heat 
generation, rupture or ignition. 

 

DISASSEMBLY 

PROHIBITED 

If fluid leaks from the battery and 
gets in the eyes, flush it out.

 Do 

not rub the eyes, and after 
immediately flushing out thoroughly 
with clean water, see a doctor. 

 

MANDATORY 

 

Refrain from touching the 
terminals to other metal items, to 
avoid causing a short in the 
battery pack.

 Failure to observe this 

precaution could result in leakage of 
the battery fluid, excessive heat 
generation, rupture or ignition. When 
transporting the battery pack, carry it 
in the soft case, etc. 

 

PROHIBITED 

Do not cause the unit to become 
wet by immersing in water, salt 
water or liquid chemicals.

  Failure 

to observe this precaution could 
result in leakage of the battery fluid, 
excessive heat generation, rupture 
or ignition. 

 

PROHIBITED 

Do not apply heat to the unit or 
throw it into a fire.

 Failure to 

observe this precaution could result 
in leakage of the battery fluid, 
excessive heat generation, rupture 
or ignition. 

 

PROHIBITED 

Do not leave unit where it will be exposed to direct sunlight or in areas that will 
become very hot, such as interiors of cars, near heating equipment, etc.

 Failure to 

observe this precaution could result in leakage of the battery fluid, excessive heat 
generation, rupture or ignition. 

 

PROHIBITED 

Do not forcibly insert the battery 
pack.

 The battery pack must be 

inserted into the 

SonicMan

 and the 

charger with the proper orientation. 
Forcible insertion could result in fluid 
leakage, excessive heat generation, 
rupture or ignition. 

 

PROHIBITED 

Do not use the battery pack in 
devices other than the 

SonicMan

 

unit.

 Failure to observe this 

precaution could result in battery 
pack failure, rupture or fire. 

 

PROHIBITED 

 
 
 

Cease use of the battery pack immediately if the unit exhibits abnormal operation.

 If 

during battery pack use, charging or storage, irregularities such as fluid leakage, an unusual 
smell, unusual heat generation, discoloration or deformation are noticed, cease use of the 
unit immediately. If use is continued under such conditions, excessive heat generation, 
ignition or rupture may result. 

 

PROHIBITED 

If full charging does not occur 
even after the prescribed charging 
time has been exceeded, stop 
charging.

 If use is continued under 

such conditions, battery fluid leakage, 
excessive heat generation, ignition or 
rupture may result. 

 

MANDATORY 

 

If battery fluid leaks and comes 
into contact with the body, rinse it 
of immediately.

 There is danger of 

resultant damage to the skin. 
Immediately rinse any battery fluid 
off with clean water. 

 

MANDATORY 

 

 

DANGER 

WARNING 

Содержание SonicMan SN1

Страница 1: ...02 SonicMan SN1 24 February 2005 Ultrasonic Leak Detector SonicMan SN1 Copyright 2005 by TLV CO LTD All rights reserved ISO 9001 ISO 14001 Manufacturer Kakogawa Japan is approved by LRQA LTD to ISO 9...

Страница 2: ...refully before use and follow the instructions to be sure of using the product properly Additionally as these manuals are necessary not only for initial software setup but also for subsequent troubles...

Страница 3: ...Decreasing the Sensitivity 15 7 5 Using the Automatic Sensitivity Adjustment 15 7 6 Turning the Laser Pointer ON and OFF 15 8 Estimating Leak Level Saving and Recalling Data 16 8 1 Hold the Inspection...

Страница 4: ...1 SonicMan Standard Set 072 65284M 02 SonicMan SN1 24 Feb 2005 4 1 SonicMan Standard Set SonicMan SN1 Nozzle Holster Earphones Battery Pack Charger Power Cord Storage Case Instruction Manual...

Страница 5: ...installation use maintenance and repair Furthermore TLV accepts no responsibility for any accidents or damage occurring as a result of failure to observe these precautions Symbols Indicates a DANGER...

Страница 6: ...isions PROHIBITED Be attentive to the background noises in the surrounding area When wearing the earphones it becomes difficult to hear noises from the surrounding area Operate the unit together with...

Страница 7: ...upture or ignition PROHIBITED Do not leave unit where it will be exposed to direct sunlight or in areas that will become very hot such as interiors of cars near heating equipment etc Failure to observ...

Страница 8: ...oltage Failure to observe this precaution could result in smoke ignition rupture or fire from the charger or battery pack MANDATORY Do not disassemble or modify Failure to observe this precaution coul...

Страница 9: ...l smell immediately pull the power plug out of the outlet If use is continued under such conditions fire or electrical shock may result PROHIBITED 2 4 Earphones Precautions Do not use earphones while...

Страница 10: ...ating the directional ability of the ultrasonic microphone facilitates the identification of leak locations and the added use of the laser pointer effects a great increase in the efficiency of leak de...

Страница 11: ...lay Area This is used to display inspection readings bar indicator and digital display and setting sensitivity and Buttons These are used to modify sensitivity settings and to modify the record number...

Страница 12: ...er pointer to pinpoint the source of the leak 5 3 Recording the Detection Reading and Leak Location 1 Estimate the leak level by using the inspection data see section 8 2 Estimating Leakage Level By e...

Страница 13: ...hite button again Discharging ceases the green discharge light goes out and charging red light automatically begins 6 When charging is fully completed the red charging indicator light begins blinking...

Страница 14: ...et Areas 1 Lift up the cover for the SonicMan earphone jack c 2 Insert the earphone plug into the SonicMan earphone jack d 3 The earphone with the R is for the right ear and the one with the L is for...

Страница 15: ...ically set the sensitivity to an easy to hear level without the use of the and buttons 1 Pull and hold the trigger for at least 1 second 2 The sensitivity setting is automatically altered until the cu...

Страница 16: ...n to confirm the data and then move to the next data item c When the nozzle is attached the distance to the front the nozzle is 0 1 m 2 Select Fluid Type Select either Steam or Gas a Scroll through th...

Страница 17: ...mode c Measurement data can be stored even if the leak level was not calculated 2 If the selected record number has already been used SonicMan will query Over write a To destroy the previous data and...

Страница 18: ...both the Func and the Memory button at the same time A menu offering the following choices will appear Delete only the selected record number No Clear Delete all saved data All Data Clear 3 Use the an...

Страница 19: ...a Clear No 001 Clear All Data Clear Select the top or bottom half using the and buttons Func Memory Press Simultaneously Delete ENT Func Cancel Deletion ENT Save New Data Record Double click Trigger P...

Страница 20: ...whether to enter calculation mode automatically Auto when a reading is taken or to enter data manually Manual at some other time 1 Press and to switch between Auto and Manual 2 Press ENT to move the...

Страница 21: ...justment while monitoring the sound from the earphones 1 Pressing the or button one time adjusts the level one step If the button is pressed and held down the level is continuously adjusted until the...

Страница 22: ...maximum the button must be held down continuously for approximately 7 seconds 2 Press ENT to move the display to the next setting item 3 Press Func to return to detection mode 10 11 Adjusting the Dis...

Страница 23: ...in which one wishes to further home in on the leak location Use of the nozzle makes it possible to collect the ultrasonic waves in the direction in which the SonicMan is pointing with greater accurac...

Страница 24: ...Put on the earphones The earpiece marked R is for the right ear the one marked L is for the left ear Place the cord behind your neck 3 Wind the cord holder to adjust the cord to an appropriate length...

Страница 25: ...attached Attach the included battery pack making sure that it is fully charged Is the battery pack being used the one that was supplied with SonicMan Attach SonicMan s specialized battery pack Is the...

Страница 26: ...to ON if the unit is in a mode other than detection mode no laser beam will be emitted Return the unit to detection mode and again check the status of the laser beam No laser beam is emitted from the...

Страница 27: ...y pack rechargeable nickel metal hydride battery 2 4 V 1650 mA h Continuous Use Time After full charge Approx 11 hours both backlight and laser pointer OFF Approx 8 hours backlight ON laser pointer OF...

Страница 28: ...TLV CO LTD authorized service representatives 2 Malfunctions due to dirt or scale 3 Malfunctions due to improper disassembly and reassembly dropping or other impact or due to inadequate inspection an...

Отзывы: